Peer-reviewedCC BYInternational Journal of Cardiology: Heart & Vasculature

Quantitative flow ratio (QFR) in routine practice: diagnostic performance and reproducibility

4 affiliations
  1. 1Klinik und Poliklinik für Kardiologie, Universitätsklinikum Leipzig, Germany; Corresponding author at: Universitätsklinikum Leipzig, Klinik und Poliklinik für Kardiologie, Liebigstraße 20, D-04103 Leipzig, Germany.
  2. 2Klinik und Poliklinik für Kardiologie, Universitätsklinikum Leipzig, Germany; Hautzentrum Nymphenburg, München, Germany
  3. 3Klinik für Anästhesie, Intensiv-, Notfall- und Schmerzmedizin, BG Klinik Bergmannstrost, Halle, Germany
  4. 4Klinik und Poliklinik für Kardiologie, Universitätsklinikum Leipzig, Germany

Abstract

Background: Quantitative flow ratio is an angiography-derived, adenosine- and wire-free method for functional coronary assessment. Data on its diagnostic performance and reproducibility relative to invasive indices remain limited. Methods: We prospectively enrolled 95 patients with 101 coronary vessels. Instantaneous wave-free ratio was assessed in 76 vessels and resting full-cycle ratio in 25. Haemodynamic significance was defined as an invasive index of 0.89 or less and a quantitative flow ratio of 0.80 or less. Observer 1 performed two measurements and observer 2 one independent measurement. Diagnostic performance and reproducibility were assessed using intraclass correlation coefficients, root-mean-square within-subject coefficients of variation, Bland-Altman analysis, Cohen's kappa and classification changes. Results: Vessels comprised 52 left anterior descending, 19 left circumflex and 30 right coronary arteries. Correlation coefficients were 0.722, 0.649 and 0.703, respectively (all p < 0.001). Corresponding areas under the receiver-operating-characteristic curve were 0.919, 0.930 and 0.899, with diagnostic accuracies of 89.1%, 88.1% and 88.1%. Intraobserver and interobserver intraclass correlation coefficients were 0.869 and 0.855. Mean differences were 0.018 ± 0.070 and 0.016 ± 0.075, with 95% limits of agreement from −0.120 to 0.156 and from −0.131 to 0.164. Three vessels were reclassified in each comparison. Agreement did not differ significantly between vessels with invasive indices of 0.89 or less and those with values above 0.89. Conclusion: Quantitative flow ratio demonstrated good diagnostic performance and reproducibility. However, individual measurement differences may be clinically relevant near the 0.80 threshold. Borderline results warrant cautious interpretation and consideration of invasive physiological confirmation when treatment decisions may be affected.

Related

  1. OS08.7.A Nanopore sequencing of cell-free CSF in routine clinical practice complements cytology and improves diagnostic sensitivity in CNS malignancies
    A Hartl, K Mauch-Mücke, A Wefers +2
    Neuro-OncologyPeer-reviewedPublisher termsFull textOncologyPMC
  2. D-dimer in Routine Hospital Practice: Diagnostic Accuracy for Venous Thromboembolism
    Ammour Abdesselam, Reda Amrani Souhli, Moussab Arbai +1
    CureusPeer-reviewedCC BY 4.0Full textGeneral medicinePMC
  3. Diagnostic performance of spectral CT quantitative parameters in predicting spread through air spaces of lung adenocarcinoma
    Quantitative imaging in medicine and surgeryPeer-reviewedCC BY-NC-NDFull textMedical imaging & radiologyEurope PMC
  4. Reproducibility and diagnostic performance of ADC for assessing response to neoadjuvant immunotherapy in muscle-invasive bladder cancer: a multi-ROI comparison analysis from the phase-Ib NABUCCO trial
    Joyce Greidanus, Carlotta Bernabei, Kalina Chupetvloska +9
    Insights into imagingPeer-reviewedCC BYFull textMedical imaging & radiologyEurope PMCCrossref
  5. Diagnostic performance of routine platelet indices and novel hemogram-derived composite biomarkers in adult sepsis
    Cemile Uyar, Emel Koçak, Öznur Ak +4
    Frontiers in MedicinePeer-reviewedCC BY 4.0Full textGeneral medicinePMC
BibTeX
@article{antoniadis2026quantitative,
  title = {{Quantitative flow ratio (QFR) in routine practice: diagnostic performance and reproducibility}},
  author = {M. Antoniadis and L. Weissenseel and J. Stader and M. Blum and J. Kandels and M. Metze and R. Wachter and U. Laufs and K. Lenk},
  journal = {International Journal of Cardiology: Heart \& Vasculature},
  year = {2026},
  month = nov,
  doi = {10.1016/j.ijcha.2026.102045},
  url = {https://doi.org/10.1016/j.ijcha.2026.102045},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Quantitative flow ratio (QFR) in routine practice: diagnostic performance and reproducibility
AU  - M. Antoniadis
AU  - L. Weissenseel
AU  - J. Stader
AU  - M. Blum
AU  - J. Kandels
AU  - M. Metze
AU  - R. Wachter
AU  - U. Laufs
AU  - K. Lenk
PY  - 2026
DA  - 2026/11/23
JO  - International Journal of Cardiology: Heart & Vasculature
DO  - 10.1016/j.ijcha.2026.102045
UR  - https://doi.org/10.1016/j.ijcha.2026.102045
AB  - Background: Quantitative flow ratio is an angiography-derived, adenosine- and wire-free method for functional coronary assessment. Data on its diagnostic performance and reproducibility relative to invasive indices remain limited. Methods: We prospectively enrolled 95 patients with 101 coronary vessels. Instantaneous wave-free ratio was assessed in 76 vessels and resting full-cycle ratio in 25. Haemodynamic significance was defined as an invasive index of 0.89 or less and a quantitative flow ratio of 0.80 or less. Observer 1 performed two measurements and observer 2 one independent measurement. Diagnostic performance and reproducibility were assessed using intraclass correlation coefficients, root-mean-square within-subject coefficients of variation, Bland-Altman analysis, Cohen's kappa and classification changes. Results: Vessels comprised 52 left anterior descending, 19 left circumflex and 30 right coronary arteries. Correlation coefficients were 0.722, 0.649 and 0.703, respectively (all p < 0.001). Corresponding areas under the receiver-operating-characteristic curve were 0.919, 0.930 and 0.899, with diagnostic accuracies of 89.1%, 88.1% and 88.1%. Intraobserver and interobserver intraclass correlation coefficients were 0.869 and 0.855. Mean differences were 0.018 ± 0.070 and 0.016 ± 0.075, with 95% limits of agreement from −0.120 to 0.156 and from −0.131 to 0.164. Three vessels were reclassified in each comparison. Agreement did not differ significantly between vessels with invasive indices of 0.89 or less and those with values above 0.89. Conclusion: Quantitative flow ratio demonstrated good diagnostic performance and reproducibility. However, individual measurement differences may be clinically relevant near the 0.80 threshold. Borderline results warrant cautious interpretation and consideration of invasive physiological confirmation when treatment decisions may be affected.
SN  - 2352-9067
ER  -