Patient-level diagnostic performance of myocardial contrast echocardiography using ultrasound-enhancing agents after acute myocardial infarction: comparison with radionuclide perfusion-metabolism imaging
- 1Department of Ultrasound, Zhongshan Hospital of Xiamen University, School of Medicine, Xiamen University
- 2Department of Nuclear Medicine, Zhongshan Hospital of Xiamen University, School of Medicine, Xiamen University
Abstract
Objective: This study evaluated the patient-level diagnostic performance and agreement of myocardial contrast echocardiography (MCE) for assessing myocardial viability after acute myocardial infarction (AMI), using combined radionuclide perfusion-metabolism imaging as the reference standard.
Methods: This retrospective diagnostic-comparison study included 141 patients with AMI who underwent MCE and reference radionuclide perfusion-metabolism imaging between February 2017 and February 2023. Imaging was generally performed during the subacute phase, 7–14 days after symptom onset. Reference assessment combined ⁹⁹ mTc-MIBI myocardial perfusion imaging with ¹⁸ F-FDG metabolic imaging. The standardized 17-segment left ventricular model was used as an anatomical framework for image interpretation; however, because individual segment-level classifications were not systematically archived, diagnostic performance was evaluated at the patient level. MCE examinations were interpreted independently by experienced cardiologists blinded to the reference imaging results, with disagreements resolved by consensus. Sensitivity, specificity, accuracy, positive predictive value (PPV), negative predictive value (NPV), and Cohen's kappa were calculated with 95% confidence intervals (CIs).
Results: Reference imaging classified 91 patients as having viable myocardium and 50 as having non-viable myocardium. MCE yielded 79 true-positive, 44 true-negative, 6 false-positive, and 12 false-negative classifications. Patient-level sensitivity was 86.81% (95% CI, 78.35%–92.29%), specificity was 88.00% (95% CI, 76.20%–94.38%), and overall accuracy was 87.23% (95% CI, 80.72%–91.77%). PPV was 92.94% (95% CI, 85.44%–96.72%), and NPV was 78.57% (95% CI, 66.18%–87.29%). Agreement between MCE and reference imaging was substantial (Cohen's κ = 0.728; 95% CI, 0.612–0.845; P < 0.001).
Conclusion: MCE demonstrated substantial patient-level agreement with radionuclide perfusion-metabolism imaging for post-AMI myocardial viability assessment. These findings support its potential role as a complementary diagnostic imaging modality under the evaluated conditions. However, the present study did not assess subsequent functional recovery, ventricular remodeling, revascularization benefit, treatment decisions, or clinical outcomes; therefore, no conclusions regarding patient-management benefit or prognostic utility can be drawn from these data.
Related
- Diagnostic performance of ultrasound for gastric volvulus in pediatric patients
- Diagnostic Performance of Color Doppler Ultrasound for Detecting Nuchal Cord and Associated Immediate Neonatal Outcomes at Term in Uganda: A Prospective Diagnostic‐Accuracy Cohort Study
- Diagnostic performance of ultrasound elastography for assessing liver stiffness in children with non-alcoholic fatty liver disease and biliary atresia
- Diagnostic performance and clinical integration of an artificial intelligence–assisted ultrasound decision support tool for thyroid nodules at a tertiary cancer centre
- Diagnostic performance of lung ultrasound in patients with clinically suspected interstitial lung disease
BibTeX
@article{gan2026patientlevel,
title = {{Patient-level diagnostic performance of myocardial contrast echocardiography using ultrasound-enhancing agents after acute myocardial infarction: comparison with radionuclide perfusion-metabolism imaging}},
author = {Shu-Fen Gan and Jiang-Hua Chen and Fu Su and Hong Zhang},
journal = {Frontiers in Cardiovascular Medicine},
year = {2026},
month = nov,
doi = {10.3389/fcvm.2026.1973019},
url = {https://www.frontiersin.org/articles/10.3389/fcvm.2026.1973019/full},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Patient-level diagnostic performance of myocardial contrast echocardiography using ultrasound-enhancing agents after acute myocardial infarction: comparison with radionuclide perfusion-metabolism imaging
AU - Shu-Fen Gan
AU - Jiang-Hua Chen
AU - Fu Su
AU - Hong Zhang
PY - 2026
DA - 2026/11/11
JO - Frontiers in Cardiovascular Medicine
DO - 10.3389/fcvm.2026.1973019
UR - https://www.frontiersin.org/articles/10.3389/fcvm.2026.1973019/full
AB - Objective: This study evaluated the patient-level diagnostic performance and agreement of myocardial contrast echocardiography (MCE) for assessing myocardial viability after acute myocardial infarction (AMI), using combined radionuclide perfusion-metabolism imaging as the reference standard. Methods: This retrospective diagnostic-comparison study included 141 patients with AMI who underwent MCE and reference radionuclide perfusion-metabolism imaging between February 2017 and February 2023. Imaging was generally performed during the subacute phase, 7–14 days after symptom onset. Reference assessment combined ⁹⁹ mTc-MIBI myocardial perfusion imaging with ¹⁸ F-FDG metabolic imaging. The standardized 17-segment left ventricular model was used as an anatomical framework for image interpretation; however, because individual segment-level classifications were not systematically archived, diagnostic performance was evaluated at the patient level. MCE examinations were interpreted independently by experienced cardiologists blinded to the reference imaging results, with disagreements resolved by consensus. Sensitivity, specificity, accuracy, positive predictive value (PPV), negative predictive value (NPV), and Cohen's kappa were calculated with 95% confidence intervals (CIs). Results: Reference imaging classified 91 patients as having viable myocardium and 50 as having non-viable myocardium. MCE yielded 79 true-positive, 44 true-negative, 6 false-positive, and 12 false-negative classifications. Patient-level sensitivity was 86.81% (95% CI, 78.35%–92.29%), specificity was 88.00% (95% CI, 76.20%–94.38%), and overall accuracy was 87.23% (95% CI, 80.72%–91.77%). PPV was 92.94% (95% CI, 85.44%–96.72%), and NPV was 78.57% (95% CI, 66.18%–87.29%). Agreement between MCE and reference imaging was substantial (Cohen's κ = 0.728; 95% CI, 0.612–0.845; P < 0.001). Conclusion: MCE demonstrated substantial patient-level agreement with radionuclide perfusion-metabolism imaging for post-AMI myocardial viability assessment. These findings support its potential role as a complementary diagnostic imaging modality under the evaluated conditions. However, the present study did not assess subsequent functional recovery, ventricular remodeling, revascularization benefit, treatment decisions, or clinical outcomes; therefore, no conclusions regarding patient-management benefit or prognostic utility can be drawn from these data.
SN - 2297-055X
ER -