Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 23 min ago
Peer-reviewedCC BYDigital Health

Large language models for patient education after prostate surgery: A comparative assessment of quality, readability, and actionability

Abstract

Background Postoperative education after prostate surgery must cover catheter care, bleeding, activity, urinary symptoms, pelvic floor training, and—after radical prostatectomy—sexual recovery. Large language models (LLMs) could provide scalable patient-facing information, but their performance for procedure-specific rehabilitation advice is uncertain. Objective To describe the quality, readability, actionability, and clinical accuracy of LLM-generated patient education for rehabilitation after prostate surgery, and to compare the original mixed-specificity queries with subsequently administered queries naming transurethral resection of the prostate (TURP) or radical prostatectomy, using procedure-matched human reference documents as descriptive comparators. Methods In this cross-sectional descriptive comparison, five LLM versions (GPT-5.2, Gemini 3.1 Pro, Claude Sonnet 4.6, Kimi K2.5, and DeepSeek-V3.2) answered 18 standardized queries in three conditions: eight original queries retained from the first phase (labelled “generic” but not uniformly procedure-agnostic), five TURP-specific queries, and five radical-prostatectomy-specific queries. Each query was submitted once per model through its official interface, yielding 90 LLM materials; all data were generated between 1 and 20 April 2026 (original mixed-specificity responses 1–10 April 2026; TURP-specific responses 11–15 April 2026; radical-prostatectomy-specific responses 16–20 April 2026); 13 matched sections from two human-developed reference documents (eight TURP sections and five radical-prostatectomy sections) served as descriptive comparators (103 materials in total). Materials were assessed with DISCERN, the Patient Education Materials Assessment Tool (PEMAT), four readability formulas, and a 5-point expert accuracy rating by two chief physicians in urology. Results were summarized descriptively with exact 95% confidence intervals, per-instrument inter-rater reliability, and exploratory correlations. Results The human reference sections had the highest descriptive scores. Under the original mixed-specificity condition, DISCERN total scores were 69.5 ± 3.5 for the TURP reference, compared with 65.8 ± 5.4 (Claude), 63.2 ± 5.9 (GPT-5.2), 61.7 ± 5.8 (DeepSeek), 59.2 ± 6.6 (Kimi), and 56.6 ± 7.2 (Gemini); Flesch-Kincaid Grade Level ranged from 8.8 ± 1.4 to 12.5 ± 3.7 among models, versus 4.0 ± 0.9 for the TURP reference and 9.0 ± 1.0 for the radical-prostatectomy reference. On the five topics common to all three conditions, the subsequently administered procedure-specific query sets were associated with higher expert accuracy (mean 3.42 with original mixed-specificity queries vs 3.96 with TURP-specific and 3.84 with radical-prostatectomy-specific prompts; mean within-model gain +0.54 and +0.42 points, respectively) and lower error rates (60.0% [15/25] vs 28.0% [7/25] and 40.0% [10/25], respectively). Because the query sets differed in wording, procedure specificity, and generation phase, these comparisons do not isolate an effect of procedure naming. Across all eight original queries, the error rate was 42.5% (17/40; 95% CI 27.0–59.1). Errors were dominated by omissions of critical information (24/34, 70.6%) and clustered in follow-up/warning signs and catheter care. Inter-rater agreement was good for DISCERN (ICC[2,1] = 0.78) and moderate for expert accuracy (0.66), but poor for PEMAT actionability overall (0.29). Conclusions In this time-stamped descriptive evaluation, LLMs produced procedure-relevant but harder-to-read, descriptively less actionable, and less clinically accurate patient education than matched human reference sections. Accuracy was modestly higher in the procedure-specific query sets, but this between-phase difference cannot be attributed to procedure naming alone. Errors concentrated in warning signs and catheter care. LLM-generated materials should be treated as clinician-reviewed drafting aids rather than standalone patient education, and future studies should use procedure-specific reference standards and repeated sampling.

Related

  1. Comparative evaluation of large language models for esophageal cancer patient education: quality, reliability, readability, understandability, and actionability.
    Ying Ying Hang, Rui Yuan, Man Lu +4
    Frontiers in medicinePeer-reviewedCC BYFull textEpidemiology & public healthEurope PMCPMC
  2. Comparative evaluation of ChatGPT, DeepSeek, and Doubao for pediatric IgA vasculitis patient education: content quality, reliability, readability, understandability, and actionability
    Ximing Fei, Jiao Zhang, Qiuye Li +1
    Frontiers in MedicinePeer-reviewedCC BY 4.0Full textEpidemiology & public healthPMC
  3. Comparative assessment of patient education content generated by five large language models on post-stroke complications: A cross-sectional study of safety, accuracy, reliability, readability, and empathy
    Long-Xian Liu, Huan-Huan Wang, Shuang Lu +8
    Digital HealthPeer-reviewedCC BY-NC 4.0Full textEpidemiology & public healthPMC
  4. Quality, Readability, Understandability, and Actionability of AI Chatbots’ Responses to Dental Patient Questions: A Comparative Evaluation
    Diagnostics (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
  5. Validity, reliability, and readability of large language model chatbots for melanoma public education: a cross-sectional comparative study
    Yi Wei, Tianjing Yu, Daitian Tang +3
    Frontiers in Public HealthPeer-reviewedCC BY 4.0Epidemiology & public healthFrontiersCrossref
BibTeX
@article{wang2026large,
  title = {{Large language models for patient education after prostate surgery: A comparative assessment of quality, readability, and actionability}},
  author = {Yinbiao Wang and Peng Wang and Luyu Zhang},
  journal = {Digital Health},
  year = {2026},
  month = nov,
  doi = {10.1177/20552076261512652},
  url = {https://doi.org/10.1177/20552076261512652},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Large language models for patient education after prostate surgery: A comparative assessment of quality, readability, and actionability
AU  - Yinbiao Wang
AU  - Peng Wang
AU  - Luyu Zhang
PY  - 2026
DA  - 2026/11/26
JO  - Digital Health
DO  - 10.1177/20552076261512652
UR  - https://doi.org/10.1177/20552076261512652
AB  - Background Postoperative education after prostate surgery must cover catheter care, bleeding, activity, urinary symptoms, pelvic floor training, and—after radical prostatectomy—sexual recovery. Large language models (LLMs) could provide scalable patient-facing information, but their performance for procedure-specific rehabilitation advice is uncertain. Objective To describe the quality, readability, actionability, and clinical accuracy of LLM-generated patient education for rehabilitation after prostate surgery, and to compare the original mixed-specificity queries with subsequently administered queries naming transurethral resection of the prostate (TURP) or radical prostatectomy, using procedure-matched human reference documents as descriptive comparators. Methods In this cross-sectional descriptive comparison, five LLM versions (GPT-5.2, Gemini 3.1 Pro, Claude Sonnet 4.6, Kimi K2.5, and DeepSeek-V3.2) answered 18 standardized queries in three conditions: eight original queries retained from the first phase (labelled “generic” but not uniformly procedure-agnostic), five TURP-specific queries, and five radical-prostatectomy-specific queries. Each query was submitted once per model through its official interface, yielding 90 LLM materials; all data were generated between 1 and 20 April 2026 (original mixed-specificity responses 1–10 April 2026; TURP-specific responses 11–15 April 2026; radical-prostatectomy-specific responses 16–20 April 2026); 13 matched sections from two human-developed reference documents (eight TURP sections and five radical-prostatectomy sections) served as descriptive comparators (103 materials in total). Materials were assessed with DISCERN, the Patient Education Materials Assessment Tool (PEMAT), four readability formulas, and a 5-point expert accuracy rating by two chief physicians in urology. Results were summarized descriptively with exact 95% confidence intervals, per-instrument inter-rater reliability, and exploratory correlations. Results The human reference sections had the highest descriptive scores. Under the original mixed-specificity condition, DISCERN total scores were 69.5 ± 3.5 for the TURP reference, compared with 65.8 ± 5.4 (Claude), 63.2 ± 5.9 (GPT-5.2), 61.7 ± 5.8 (DeepSeek), 59.2 ± 6.6 (Kimi), and 56.6 ± 7.2 (Gemini); Flesch-Kincaid Grade Level ranged from 8.8 ± 1.4 to 12.5 ± 3.7 among models, versus 4.0 ± 0.9 for the TURP reference and 9.0 ± 1.0 for the radical-prostatectomy reference. On the five topics common to all three conditions, the subsequently administered procedure-specific query sets were associated with higher expert accuracy (mean 3.42 with original mixed-specificity queries vs 3.96 with TURP-specific and 3.84 with radical-prostatectomy-specific prompts; mean within-model gain +0.54 and +0.42 points, respectively) and lower error rates (60.0% [15/25] vs 28.0% [7/25] and 40.0% [10/25], respectively). Because the query sets differed in wording, procedure specificity, and generation phase, these comparisons do not isolate an effect of procedure naming. Across all eight original queries, the error rate was 42.5% (17/40; 95% CI 27.0–59.1). Errors were dominated by omissions of critical information (24/34, 70.6%) and clustered in follow-up/warning signs and catheter care. Inter-rater agreement was good for DISCERN (ICC[2,1] = 0.78) and moderate for expert accuracy (0.66), but poor for PEMAT actionability overall (0.29). Conclusions In this time-stamped descriptive evaluation, LLMs produced procedure-relevant but harder-to-read, descriptively less actionable, and less clinically accurate patient education than matched human reference sections. Accuracy was modestly higher in the procedure-specific query sets, but this between-phase difference cannot be attributed to procedure naming alone. Errors concentrated in warning signs and catheter care. LLM-generated materials should be treated as clinician-reviewed drafting aids rather than standalone patient education, and future studies should use procedure-specific reference standards and repeated sampling.
SN  - 2055-2076
ER  -