Skip to content
DraconiticResearch
Search Sources API
197,768 studies31 sourcesUpdated 49 min ago
Peer-reviewedCC BY-NC-SAJournal of Medical Physics

FLUKA Monte Carlo-based Evaluation of Linear Energy Transfer Distributions for Monoenergetic Therapeutic Carbon-ion Beams in Water

Abstract

Background: This study aims to calculate the distribution of linear energy transfer (LET) and its moments such as fluence-averaged LET (LETf) and dose-averaged LET (LETd) as a function of on-axis depth in water for monoenergetic carbon-ion beams with energies ranging from 80 to 480 MeV/u. Materials and Methods: Depth-dose profiles, LET distributions, LETf, and LETd are calculated as a function of on-axis depth in a 40 cm × 40 cm × 40 cm unit-density liquid water phantom using the FLUKA Monte Carlo code, fully incorporating the contributions of primary ions and all secondary charged fragments. Results: Results show that both LETf and LETd increase with depth and reach a maximum near the Bragg peak region, followed by a rapid fall-off in the distal region as the fluence of heavy ion fragments decreases. Higher beam energies result in deeper LET peaks and more pronounced fragmentation tails in the depth-dose profiles. In the Bragg peak region, depending on beam energy, the LETf and LETd values are in the range of 11.7–106.4 keV/mm and 210.7–384.6 keV/mm, respectively. Conclusion: Overall, the results provide a comprehensive characterization of physical and radiobiological parameters for monoenergetic carbon-ion beams in the therapeutic energy range, essential for benchmarking LET-based RBE models, improving treatment plan robustness, and optimizing biological dose delivery in carbon-ion radiotherapy.

Related

  1. Original W'-balance models do not transfer to high-intensity interval training in trained adult runners: Proposal of a single-coefficient linear alternative.
    Felipe García-Pinillos, Diego Jaén-Carrillo, Leonardo Riquelme-Sebastián +5
    Physiological reportsPeer-reviewedCC BYFull textSurgery & anaesthesiaEurope PMCDOAJ
  2. Dual-Source Photon-Counting CT for Thoracic Arteries: Enhancing Image Quality and Diagnostic Assessability with Low-Energy Virtual Monoenergetic Imaging.
    Andreea I Nica, Christian Booz, Giuseppe M Bucolo +14
    Diagnostics (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
  3. Diabetic retinal neurovascular unit injury: mechanisms, imaging evaluation, and integrated therapeutic strategies
    Hui Liu, Jing Wu, Heng Jiang +1
    Frontiers in medicinePeer-reviewedCC BYFull textGeneral medicineEurope PMC
  4. Reducing Stent-Induced Blooming Artifacts Using Virtual Monoenergetic Imaging Reconstructions in a Superficial Femoral Artery Phantom: An In-Vitro Study
    Lisa Rutten, Lennart van de Velde, Cornelis H. Slump +4
    Cardiovascular Engineering and TechnologyPeer-reviewedCC BY 4.0Full textGeneral medicinePMC
  5. Evaluation of Therapeutic Drug Monitoring for Vancomycin with Ratio of Area Under the Curve to Minimum Inhibitory Concentration at a Children’s and Women’s Tertiary Hospital
    Alyssa Azote, Roxane Carr, Kaitlin McDougal +2
    The Canadian Journal of Hospital PharmacyPeer-reviewedLicence not statedFull textPharmacology & toxicologyPMC
BibTeX
@article{chattaraj2026fluka,
  title = {{FLUKA Monte Carlo-based Evaluation of Linear Energy Transfer Distributions for Monoenergetic Therapeutic Carbon-ion Beams in Water}},
  author = {Arghya Chattaraj and T. Palani Selvam and Vandana Shrivastava},
  journal = {Journal of Medical Physics},
  year = {2026},
  month = jul,
  doi = {10.4103/jmp.jmp_140_26},
  url = {https://doi.org/10.4103/jmp.jmp_140_26},
  note = {CC BY-NC-SA},
}
RIS
TY  - JOUR
TI  - FLUKA Monte Carlo-based Evaluation of Linear Energy Transfer Distributions for Monoenergetic Therapeutic Carbon-ion Beams in Water
AU  - Arghya Chattaraj
AU  - T. Palani Selvam
AU  - Vandana Shrivastava
PY  - 2026
DA  - 2026/07/01
JO  - Journal of Medical Physics
DO  - 10.4103/jmp.jmp_140_26
UR  - https://doi.org/10.4103/jmp.jmp_140_26
AB  - Background: This study aims to calculate the distribution of linear energy transfer (LET) and its moments such as fluence-averaged LET (LETf) and dose-averaged LET (LETd) as a function of on-axis depth in water for monoenergetic carbon-ion beams with energies ranging from 80 to 480 MeV/u. Materials and Methods: Depth-dose profiles, LET distributions, LETf, and LETd are calculated as a function of on-axis depth in a 40 cm × 40 cm × 40 cm unit-density liquid water phantom using the FLUKA Monte Carlo code, fully incorporating the contributions of primary ions and all secondary charged fragments. Results: Results show that both LETf and LETd increase with depth and reach a maximum near the Bragg peak region, followed by a rapid fall-off in the distal region as the fluence of heavy ion fragments decreases. Higher beam energies result in deeper LET peaks and more pronounced fragmentation tails in the depth-dose profiles. In the Bragg peak region, depending on beam energy, the LETf and LETd values are in the range of 11.7–106.4 keV/mm and 210.7–384.6 keV/mm, respectively. Conclusion: Overall, the results provide a comprehensive characterization of physical and radiobiological parameters for monoenergetic carbon-ion beams in the therapeutic energy range, essential for benchmarking LET-based RBE models, improving treatment plan robustness, and optimizing biological dose delivery in carbon-ion radiotherapy.
SN  - 0971-6203
SN  - 1998-3913
ER  -