Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 56 min ago
Peer-reviewedCC BY 4.0CVIR Endovascular

Portable endovascular disposable robotic assistant (PEDRA) for image-guided peripheral endovascular interventions: technical feasibility, safety, and future implications

  1. 1Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA USA

Abstract

Background: Traditional fixed-console endovascular robots face barriers due to high capital costs and infrastructure requirements. This study evaluates the technical feasibility and safety of the LIBERTY® Endovascular Robotic System—a portable, disposable platform—across diverse Interventional Radiology procedures and vascular access sites.

Materials and methods: A single-center retrospective review was conducted on 20 consecutive outpatient procedures performed by five operators. Cases included prostate artery embolization, uterine fibroid embolization, renal/gonadal venography, geniculate artery embolization, Y90 mapping, and Y90 radioembolization. Vascular access points included left radial and femoral approaches.

Results: Procedural technical success was achieved in 100% (20/20) of cases. 100% of vessels attempted with robotic assistance were successfully selected (31/31). Complete robotic target-vessel selection—performing all procedural aspects of vessel selection robotically—was 75% (15/20). Partial robotic target-vessel selection—conversion to manual prior to completion of all vessel selections with robotic assistance—was 25% (5/20). All 5 cases of partial robotic target-vessel selection were due to hardware malfunction, rather than an inability to select target vessels with robotic assistance. Subgroup analysis of the last 10 cases after switching to utilizing updated units demonstrated 100% complete robotic target-vessel selection (10/10). No device-related serious adverse events or complications occurred.

Conclusion: The portable and disposable robotic platform was successfully integrated into a diverse Interventional Radiology practice, demonstrating the first documented prostate artery embolization, uterine fibroid embolization, renal/gonadal venography, geniculate artery embolization, and Y90 procedures by portable and disposable robotic-assistance, as well as the first robotic-assisted endovascular procedures via radial access. Its design may lower economic and institutional barriers, potentially expanding robotic-assisted interventions to rural or non-academic settings. The portable robotic assistant is safe and feasible for complex endovascular interventions. Further prospective studies are needed to quantify ergonomic benefits and radiation reduction.

Supplementary Information: The online version contains supplementary material available at https://doi.org/10.1186/s42155-026-00789-2.

Related

  1. Intravascular ultrasound-guided versus angiography-guided endovascular interventions for peripheral artery disease: a systematic review and meta-analysis.
    Montserrat Villa Sanchez, Ruth Alejandra Diaz Revelo, Maya AlQawasmi +9
    BMC cardiovascular disordersPeer-reviewedCC BYFull textSurgery & anaesthesiaEurope PMC
  2. Pulsed X-Ray CT with Temporally Aware Reconstruction for Three-Dimensional Endovascular Guidance: Phantom Feasibility Study
    N. Azimi, A. Brian-Choux, S. Araujo +9
    medRxivPreprintAll rights reservedFull textMedical imaging & radiologymedRxiv
  3. Feasibility and Procedural Considerations of Balloon‐Expandable TAVR in Patients With Prior Endovascular Aortic Stent Grafts
    Iad Alhallak, Alexander Mills, Beau Bequeaith +6
    Catheterization and Cardiovascular InterventionsPeer-reviewedCC BY-NC-ND 4.0Full textCardiovascular medicinePMC
  4. Limb Salvage Outcomes Following Endovascular Revascularization for Peripheral Artery Disease in a Southern Indian Population: A Single-Center Retrospective Study
    Sibasankar Dalai, Aravind Varma Datla, Ananta Rao Baratam +6
    CureusPeer-reviewedCC BY 4.0Full textMedical imaging & radiologyPMCEurope PMC
  5. Treatment of Calcified Peripheral Artery Disease With the Shockwave Forward Peripheral Intravascular Lithotripsy System: One-Year Outcomes From the FORWARD PAD IDE and Mini S Feasibility Studies
    Andrew Holden, John D. Corl, Sameh Sayfo +10
    Journal of the Society for Cardiovascular Angiography & InterventionsPeer-reviewedCC BY 4.0Full textSurgery & anaesthesiaPMCEurope PMC
BibTeX
@article{khoury2026portable,
  title = {{Portable endovascular disposable robotic assistant (PEDRA) for image-guided peripheral endovascular interventions: technical feasibility, safety, and future implications}},
  author = {Joe Kevin Khoury and Nicholas Joseph Lima and Ahmed Elsahhar and Hanzhou Li and John Timothy Moon and Amir Pourmorteza and David Prologo and Junman Kim and Zachary Bercu},
  journal = {CVIR Endovascular},
  year = {2026},
  month = nov,
  doi = {10.1186/s42155-026-00789-2},
  url = {https://doi.org/10.1186/s42155-026-00789-2},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Portable endovascular disposable robotic assistant (PEDRA) for image-guided peripheral endovascular interventions: technical feasibility, safety, and future implications
AU  - Joe Kevin Khoury
AU  - Nicholas Joseph Lima
AU  - Ahmed Elsahhar
AU  - Hanzhou Li
AU  - John Timothy Moon
AU  - Amir Pourmorteza
AU  - David Prologo
AU  - Junman Kim
AU  - Zachary Bercu
PY  - 2026
DA  - 2026/11/14
JO  - CVIR Endovascular
DO  - 10.1186/s42155-026-00789-2
UR  - https://doi.org/10.1186/s42155-026-00789-2
AB  - Background: Traditional fixed-console endovascular robots face barriers due to high capital costs and infrastructure requirements. This study evaluates the technical feasibility and safety of the LIBERTY® Endovascular Robotic System—a portable, disposable platform—across diverse Interventional Radiology procedures and vascular access sites.  Materials and methods: A single-center retrospective review was conducted on 20 consecutive outpatient procedures performed by five operators. Cases included prostate artery embolization, uterine fibroid embolization, renal/gonadal venography, geniculate artery embolization, Y90 mapping, and Y90 radioembolization. Vascular access points included left radial and femoral approaches.  Results: Procedural technical success was achieved in 100% (20/20) of cases. 100% of vessels attempted with robotic assistance were successfully selected (31/31). Complete robotic target-vessel selection—performing all procedural aspects of vessel selection robotically—was 75% (15/20). Partial robotic target-vessel selection—conversion to manual prior to completion of all vessel selections with robotic assistance—was 25% (5/20). All 5 cases of partial robotic target-vessel selection were due to hardware malfunction, rather than an inability to select target vessels with robotic assistance. Subgroup analysis of the last 10 cases after switching to utilizing updated units demonstrated 100% complete robotic target-vessel selection (10/10). No device-related serious adverse events or complications occurred.  Conclusion: The portable and disposable robotic platform was successfully integrated into a diverse Interventional Radiology practice, demonstrating the first documented prostate artery embolization, uterine fibroid embolization, renal/gonadal venography, geniculate artery embolization, and Y90 procedures by portable and disposable robotic-assistance, as well as the first robotic-assisted endovascular procedures via radial access. Its design may lower economic and institutional barriers, potentially expanding robotic-assisted interventions to rural or non-academic settings. The portable robotic assistant is safe and feasible for complex endovascular interventions. Further prospective studies are needed to quantify ergonomic benefits and radiation reduction.  Supplementary Information: The online version contains supplementary material available at https://doi.org/10.1186/s42155-026-00789-2.
SN  - 2520-8934
ER  -