In X-ray scanning probe tomography, reconstruction quality generally improves with larger numbers of projections. However, additional projections increase experiment costs, acquisition time, and the radiation dose imparted to the sample. One mitigation to these trade-offs is to adopt a sequential design of experiments, in which each subsequent measurement is determined as a function of previously acquired data in order to maximize information gain. In scanning probe tomography, a widely used heuristic to maximize information is to align beams with the edges of the sample. A key challenge, however, is that the true sample is unknown, so identifying edge-aligned beams typically requires reconstructing the sample based on available measurements. This work proposes a novel sequential design method that identifies edge-aligned measurements directly from the sinogram, bypassing any reconstruction, thereby improving computational efficiency and reducing the experimental design's susceptibility to reconstruction errors. Our method dynamically selects the next set of measurement beams by maximizing an acquisition function that balances exploration and exploitation over the domain of all possible measurements, improving reconstruction quality while reducing measurement redundancy.

Related

  1. Spatially or temporally resolved phase-based optoretinography with actively-tracked point-scanning optical coherence tomography
    Léo Puyo, Jonas Franke, Felix Zeisberger +2
    arXivPreprintarXiv licenceFull textBiological & medical physicsOptics & photonicsarXiv
  2. Computed Tomography Reconstruction Algorithm Using Markov Random Field Model
    Taiga Shimomiya, Taichi Kusumi, Masayuki Uesugi +4
    arXivPreprintarXiv licenceFull textBiological & medical physicsComputational physicsarXiv
  3. Towards 3D fully randomized frequency-domain reconstruction of the speed of sound in breast ultrasound computed tomography
    Luca A. Forte
    arXivPreprintarXiv licenceFull textBiological & medical physicsComputational physicsarXiv
  4. A simplified reconstruction of Positron Emission Tomography image using Time of Flight simulated data in Gate 10
    Marcin Balcerzyk, Santiago Jimenez-Serrano, Óscar Pietrzyk +2
    arXivPreprintCC BY-NC-ND 4.0Full textBiological & medical physicsarXiv
  5. Roadmap: Image reconstruction in emission tomography for the era of fast Monte Carlo simulation
    Georg Schramm, Benjamin Auer, Ane Etxebeste +14
    arXivPreprintCC BY-NC-SA 4.0Full textBiological & medical physicsarXiv
BibTeX
@misc{dinh2026edgealigned,
  title = {{Edge-Aligned Beam Placement in Scanning Probe Tomography via Reconstruction-Free Sequential Design of Experiments}},
  author = {San Dinh and Zichao Wendy Di and Matt Menickelly},
  howpublished = {arXiv},
  year = {2026},
  month = oct,
  doi = {10.48550/arxiv.2606.21713},
  eprint = {2606.21713},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2606.21713},
  note = {CC BY 4.0},
}
RIS
TY  - UNPB
TI  - Edge-Aligned Beam Placement in Scanning Probe Tomography via Reconstruction-Free Sequential Design of Experiments
AU  - San Dinh
AU  - Zichao Wendy Di
AU  - Matt Menickelly
PY  - 2026
DA  - 2026/10/02
PB  - arXiv
DO  - 10.48550/arxiv.2606.21713
UR  - https://arxiv.org/abs/2606.21713
AB  - In X-ray scanning probe tomography, reconstruction quality generally improves with larger numbers of projections. However, additional projections increase experiment costs, acquisition time, and the radiation dose imparted to the sample. One mitigation to these trade-offs is to adopt a sequential design of experiments, in which each subsequent measurement is determined as a function of previously acquired data in order to maximize information gain. In scanning probe tomography, a widely used heuristic to maximize information is to align beams with the edges of the sample. A key challenge, however, is that the true sample is unknown, so identifying edge-aligned beams typically requires reconstructing the sample based on available measurements. This work proposes a novel sequential design method that identifies edge-aligned measurements directly from the sinogram, bypassing any reconstruction, thereby improving computational efficiency and reducing the experimental design's susceptibility to reconstruction errors. Our method dynamically selects the next set of measurement beams by maximizing an acquisition function that balances exploration and exploitation over the domain of all possible measurements, improving reconstruction quality while reducing measurement redundancy.
ER  -