Abstract

Background

Pre-partitioned brain tumor MRI collections may place exact or near-duplicate slices on both sides of a benchmark split, but the magnitude and uncertainty of the resulting performance difference are rarely measured.Methods

A unified MedNeXt-B 2D model produced a four-class label and a tumor mask from a shared encoder. For each near-duplicate-screened fold, we constructed a replacement-based contaminated condition of identical size and tumor-class-by-plane composition; this condition was not the original unscreened training pool. Validation folds and the frozen 995-slice test set were identical. Constituent source-dataset matching was not possible because BRISC2025 provides no per-image source provenance. Both conditions were trained with seeds 42, 1,337, 2,024, 3,407, and 5,090. Primary uncertainty summaries used a 10,000-resample hierarchical bootstrap over seeds and inferred pseudo-patient clusters.Results

Across five seeds, screened accuracy was 0.9652 ± 0.0023 and mean class Dice was 0.7894 ± 0.0031 (mean ± sample SD). Accuracy was higher in the replacement-based contaminated condition by a mean difference of 0.0261 ± 0.0031 (range 0.0211-0.0281; hierarchical 95% CI, 0.0207-0.0318); corresponding mean differences were 0.0315 ± 0.0049 for mean class Dice (range, 0.0252-0.0375; hierarchical 95% CI, 0.0238-0.0394) and 0.0746 ± 0.0055 for meningioma recall (range, 0.0660-0.0792; hierarchical 95% CI, 0.0590-0.0911). The screening surrogate recovers only 5.8% of known same-patient slice pairs in an independent calibration dataset, so the screened condition may retain undetected related slices, and the intervals do not establish patient-level independence.Conclusion

Retaining detected test-linked near-duplicates was associated with higher slice-level benchmark performance in this replacement-matched exploratory analysis.

Related

  1. Comparative performance of nine large language models on professional Parkinson’s disease tasks: a multidimensional benchmark study
    Ludi Xie, Rumeng Wei, Li Xiong +3
    Frontiers in NeurologyPeer-reviewedCC BY 4.0NeurologyCrossref
  2. Diagnostic and treatment recommendation performance of multimodal large language models in failed or painful total hip arthroplasty: an expert-rated benchmark study.
    Francesco Castagnini, Marco Rotini, Mara Gorgone +5
    Annals of jointPeer-reviewedCC BY-NC-NDFull textEpidemiology & public healthEurope PMC
  3. Clinical Scores and Machine Learning at Matched Variable Domains in Acute Appendicitis: Performance of Recommended Rule-Out Thresholds in a CT-Verified Cohort
    Burak Celik, Ipek Pehlivan, Alper Hatipoglu +5
    Journal of Clinical MedicinePeer-reviewedCC BY 4.0Full textGeneral medicineCrossrefEurope PMC
  4. Sport-related neurocognitive performance and repetitive head-impact exposure in elite Muay Thai athletes: a matched athletic-control study.
    Raja Syed Tengku Sulaiman
    Frontiers in sports and active livingPeer-reviewedCC BYFull textEpidemiology & public healthEurope PMCPMC
  5. AI-powered optical coherence tomography shows similar performance to intravascular ultrasound for plaque burden quantification: head-to-head benchmark study against histopathology of native coronary arteries.
    Jiayue Huang, Ruobing Dai, Xu Yu +7
    European heart journal. Digital healthPeer-reviewedCC BYFull textSurgery & anaesthesiaEurope PMC
BibTeX
@article{huang2026nearduplicate,
  title = {{Near-duplicate contamination inflates brain MRI benchmark performance: a size-matched, multi-seed MedNeXt-B study.}},
  author = {Yuhan Huang and Zhipeng Sun and Jinghui Chen and Tao Yang and Lianxin Xie and Xinchen Lin},
  journal = {Frontiers in medicine},
  year = {2026},
  month = oct,
  doi = {10.3389/fmed.2026.1955863},
  url = {https://europepmc.org/article/MED/42923803},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Near-duplicate contamination inflates brain MRI benchmark performance: a size-matched, multi-seed MedNeXt-B study.
AU  - Yuhan Huang
AU  - Zhipeng Sun
AU  - Jinghui Chen
AU  - Tao Yang
AU  - Lianxin Xie
AU  - Xinchen Lin
PY  - 2026
DA  - 2026/10/08
JO  - Frontiers in medicine
DO  - 10.3389/fmed.2026.1955863
UR  - https://europepmc.org/article/MED/42923803
AB  - Background  Pre-partitioned brain tumor MRI collections may place exact or near-duplicate slices on both sides of a benchmark split, but the magnitude and uncertainty of the resulting performance difference are rarely measured.Methods  A unified MedNeXt-B 2D model produced a four-class label and a tumor mask from a shared encoder. For each near-duplicate-screened fold, we constructed a replacement-based contaminated condition of identical size and tumor-class-by-plane composition; this condition was not the original unscreened training pool. Validation folds and the frozen 995-slice test set were identical. Constituent source-dataset matching was not possible because BRISC2025 provides no per-image source provenance. Both conditions were trained with seeds 42, 1,337, 2,024, 3,407, and 5,090. Primary uncertainty summaries used a 10,000-resample hierarchical bootstrap over seeds and inferred pseudo-patient clusters.Results  Across five seeds, screened accuracy was 0.9652 ± 0.0023 and mean class Dice was 0.7894 ± 0.0031 (mean ± sample SD). Accuracy was higher in the replacement-based contaminated condition by a mean difference of 0.0261 ± 0.0031 (range 0.0211-0.0281; hierarchical 95% CI, 0.0207-0.0318); corresponding mean differences were 0.0315 ± 0.0049 for mean class Dice (range, 0.0252-0.0375; hierarchical 95% CI, 0.0238-0.0394) and 0.0746 ± 0.0055 for meningioma recall (range, 0.0660-0.0792; hierarchical 95% CI, 0.0590-0.0911). The screening surrogate recovers only 5.8% of known same-patient slice pairs in an independent calibration dataset, so the screened condition may retain undetected related slices, and the intervals do not establish patient-level independence.Conclusion  Retaining detected test-linked near-duplicates was associated with higher slice-level benchmark performance in this replacement-matched exploratory analysis.
SN  - 2296-858X
ER  -