Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 24 min ago
PreprintarXiv licencearXiv

Diagnosing internal leakage currents through magnetometry of lithium-ion cells

Abstract

Internal leakage currents are difficult to detect and to localize through measurements at the terminals of lithium-ion cells. We measured the magnetic fields of pouch cells non-invasively with a magnetometer while a battery cycler set the current and recorded the voltage. A three-axis magnetoresistive sensor remains fixed inside a three-layer magnetic shield, and two linear stages move the cell in two dimensions relative to the sensor to acquire a map of the magnetic field above the cell. The field of an intact cell was linear in current from 10 to 420 mA, and its maps were symmetric between charge and discharge. To create internal leakage currents, two 600 mAh cells were damaged by mechanical indentation. Both cells developed a magnetic field at zero applied current that decayed over hours, while the cell voltage showed a loss of charge by self-discharge. This field breaks the symmetry between the charge and discharge maps, which allows leakage to be detected while the cell is being cycled. At rest, the setup detects leakage currents down to about 1--3 mA. The results highlight opportunities for battery diagnostics and safety, and may help in designing techniques for characterizing soft shorts.

Related

  1. Efficient Simulation of Gate Leakage Currents in Ultra-scaled Transistors from First Principles
    Mauro Dossena, Nicolas Vetsch, Alexander Maeder +6
    arXivPreprintCC BY 4.0Full textCondensed matterarXiv
  2. The Impact of Internal Electric Fields on Accurate Diamond Magnetometry
    Jack Faller, Daphne Freda Gavras, Andrew Lowther +2
    arXivPreprintCC BY 4.0Full textQuantum physics & quantum informationarXiv
  3. Measurements of sensor radiation damage in the ATLAS inner detector using leakage currents
    Georges Aad, Braden Keim Abbott, Dale Abbott +2,864
    Journal of InstrumentationPeer-reviewedCC BYFull textHigh-energy & particle physicsHAL
  4. Long interfacial internal waves with currents: current profiles with quadratic depth-dependence
    Conor T. Curtin, Rossen I. Ivanov
    arXivPreprintarXiv licenceFull textFluid dynamicsStatistical & nonlinear physicsarXiv
  5. Direct Validation of Superconductivity through Contact-Free Detection of Persistent Supercurrents Using Room-Temperature Quantum Magnetometry
    Xinyi Zeng, Chengzhen Qin, Bowen Fan +9
    arXivPreprintCC BY 4.0Full textCondensed matterarXiv
BibTeX
@misc{shukla2026diagnosing,
  title = {{Diagnosing internal leakage currents through magnetometry of lithium-ion cells}},
  author = {Shaurya Shukla and Chengtong Zhang and Yinan Hu and Stefan Benders and Mykhailo Flaks and Dmitry Budker and Alexej Jerschow},
  howpublished = {arXiv},
  year = {2026},
  month = nov,
  doi = {10.48550/arxiv.2611.34699},
  eprint = {2611.34699},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2611.34699},
}
RIS
TY  - UNPB
TI  - Diagnosing internal leakage currents through magnetometry of lithium-ion cells
AU  - Shaurya Shukla
AU  - Chengtong Zhang
AU  - Yinan Hu
AU  - Stefan Benders
AU  - Mykhailo Flaks
AU  - Dmitry Budker
AU  - Alexej Jerschow
PY  - 2026
DA  - 2026/11/25
PB  - arXiv
DO  - 10.48550/arxiv.2611.34699
UR  - https://arxiv.org/abs/2611.34699
AB  - Internal leakage currents are difficult to detect and to localize through measurements at the terminals of lithium-ion cells. We measured the magnetic fields of pouch cells non-invasively with a magnetometer while a battery cycler set the current and recorded the voltage. A three-axis magnetoresistive sensor remains fixed inside a three-layer magnetic shield, and two linear stages move the cell in two dimensions relative to the sensor to acquire a map of the magnetic field above the cell. The field of an intact cell was linear in current from 10 to 420 mA, and its maps were symmetric between charge and discharge. To create internal leakage currents, two 600 mAh cells were damaged by mechanical indentation. Both cells developed a magnetic field at zero applied current that decayed over hours, while the cell voltage showed a loss of charge by self-discharge. This field breaks the symmetry between the charge and discharge maps, which allows leakage to be detected while the cell is being cycled. At rest, the setup detects leakage currents down to about 1--3 mA. The results highlight opportunities for battery diagnostics and safety, and may help in designing techniques for characterizing soft shorts.
ER  -