Prediction of incidental obturator hernia using preoperative computed tomography: the distance between the obturator internus muscle and the pubic bone
- 1Department of General and Gastroenterological Surgery, Showa Medical University Fujigaoka Hospital, 1-30, Fujigaoka, Aoba-ku, Yokohama, 227-8501 Japan
Abstract
Introduction: Non-incarcerated obturator hernias (OH) are often difficult to diagnose preoperatively and occasionally are identified incidentally during laparoscopic groin hernia repair. Three anatomic pathways for OH protrusion have been described. Although increased distance between the obturator externus and pectineus muscles (OE–P gap) according to axial computed tomography (CT) has been considered suggestive, this measurement cannot adequately assess all herniation pathways. The present study considered whether measuring distance between the obturator internus muscle and the pubic bone (OI–P gap) using preoperative coronal CT could identify incidental OH (IOH) during transabdominal preperitoneal repair (TAPP).
Methods: We retrospectively reviewed female patients who underwent elective TAPP between 2017 and 2025. OE–P and OI–P gaps both were measured in preoperative CT images. Patients were divided into IOH and non-IOH groups, between which clinical variables and imaging findings were compared using the Wilcoxon test.
Results: Among 79 patients, IOH was identified in 9 (11%). No significant differences between groups were observed in age or body mass index. While the OE–P gap was comparable between IOH and non-IOH groups (2.5 mm vs. 2.7 mm, P = 1.000), the OI–P gap was significantly larger in the IOH than in the non-IOH group (13.6 mm vs. 9.7 mm, P = 0.005). An OI–P gap cutoff value of 12.9 mm showed sensitivity of 67% and specificity of 93% in diagnosing IOH.
Conclusion: Large OI–P gap in coronal CT images was associated with IOH and could be a useful in its detection.
Related
- An interpretable computed tomography radiomics-based machine learning model for preoperative prediction of complicated appendicitis in children.
- Incidental pulmonary nodules detected on computed tomography pulmonary angiography: prevalence and malignancy outcomes from a Thai tertiary-care center
- Computed tomography-guided percutaneous puncture injection of methylene blue mixed with autologous blood for preoperative localization of pulmonary nodules: analysis of 407 cases
- Novel cardiac computed tomography-based preoperative indicator associated with intraoperative graft flow in coronary artery bypass grafting
- Incidental Findings on Large-Field-of-View Cone Beam Computed Tomography Scans: Prevalence, Anatomical Distribution and Predictors of Clinical Relevance in a Retrospective Analysis of 203 Patients.
BibTeX
@article{nakamura2026prediction,
title = {{Prediction of incidental obturator hernia using preoperative computed tomography: the distance between the obturator internus muscle and the pubic bone}},
author = {Akihiro Nakamura and Yoshikuni Harada and Hideyuki Oyama and Kuniya Tanaka},
journal = {BMC Surgery},
year = {2026},
month = jul,
doi = {10.1186/s12893-026-04090-w},
url = {https://doi.org/10.1186/s12893-026-04090-w},
note = {CC BY-NC-ND 4.0},
}
RIS
TY - JOUR
TI - Prediction of incidental obturator hernia using preoperative computed tomography: the distance between the obturator internus muscle and the pubic bone
AU - Akihiro Nakamura
AU - Yoshikuni Harada
AU - Hideyuki Oyama
AU - Kuniya Tanaka
PY - 2026
DA - 2026/07/30
JO - BMC Surgery
DO - 10.1186/s12893-026-04090-w
UR - https://doi.org/10.1186/s12893-026-04090-w
AB - Introduction: Non-incarcerated obturator hernias (OH) are often difficult to diagnose preoperatively and occasionally are identified incidentally during laparoscopic groin hernia repair. Three anatomic pathways for OH protrusion have been described. Although increased distance between the obturator externus and pectineus muscles (OE–P gap) according to axial computed tomography (CT) has been considered suggestive, this measurement cannot adequately assess all herniation pathways. The present study considered whether measuring distance between the obturator internus muscle and the pubic bone (OI–P gap) using preoperative coronal CT could identify incidental OH (IOH) during transabdominal preperitoneal repair (TAPP). Methods: We retrospectively reviewed female patients who underwent elective TAPP between 2017 and 2025. OE–P and OI–P gaps both were measured in preoperative CT images. Patients were divided into IOH and non-IOH groups, between which clinical variables and imaging findings were compared using the Wilcoxon test. Results: Among 79 patients, IOH was identified in 9 (11%). No significant differences between groups were observed in age or body mass index. While the OE–P gap was comparable between IOH and non-IOH groups (2.5 mm vs. 2.7 mm, P = 1.000), the OI–P gap was significantly larger in the IOH than in the non-IOH group (13.6 mm vs. 9.7 mm, P = 0.005). An OI–P gap cutoff value of 12.9 mm showed sensitivity of 67% and specificity of 93% in diagnosing IOH. Conclusion: Large OI–P gap in coronal CT images was associated with IOH and could be a useful in its detection.
SN - 1471-2482
ER -