Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 3 min ago
Peer-reviewedCC BY-NCGreenfort International Journal of Applied Medical Science

Functional outcome of closed reduction and percutaneous multiple K-wire fixation of displaced intra-articular calcaneal fracture

Abstract

Background: Calcaneal fracture, being the most common tarsal bone fracture, accounts upto 65% of the cases, and 2% of all fractures. 75% of calcaneal fractures are intra-articular, which is the most common type of fracture. Displaced intra-articular calcaneal fractures (DIACF) are complex injuries associated with significant morbidity. Minimally invasive fixation seeks to restore the joint congruity while minimizing soft tissue complications seen in open approaches. In our study we evaluated the functional and radiological outcomes of closed reduction and percutaneous multiple K-wire fixation in DIACF.Methods: The study was carried out as a descriptive and prospective study in the Department of Orthopaedics, Calcutta National Medical College, Kolkata, India during the period July 2025 to December 2025. Thirty patients of 20 to 60 years, who underwent surgical fixation for displaced intra-articular calcaneal fracture using multiple K wires were followed up. Functional and radiological outcomes at six months follow up were assessed.Results: In our study of 30 patients with DIACF who underwent minimally invasive surgical fixation with k-wires, the mean final AOFAS score was 82.4 ± 6.7. Böhler angle improved from 8.6° preoperatively to 27.2° at final follow-up; Gissane angle corrected from 141.8° to 122.3°. Excellent-to-good outcomes were observed in 86.7% of patients. Complications occurred in 13.3% of cases, primarily superficial pin-tract infections; no deep infections or hardware failures were noted.Conclusion: Closed reduction and percutaneous K-wire fixation is an effective minimally invasive technique for selected DIACF, providing satisfactory functional recovery and radiographic restoration with low complication rates.

Related

  1. Does indirect reduction during minimally invasive percutaneous plate osteosynthesis for distal fibular fractures compromise mortise alignment and lead to post-traumatic osteoarthritis? A comparative study of long-term radiographic and functional outcomes comparing minimally invasive and traditional open plating
    Zhun-Yew Chang, Po-Kuan Wu, Chung-Han Ho +2
    Journal of Orthopaedic Surgery and ResearchPeer-reviewedCC BY-NC-ND 4.0Full textSurgery & anaesthesiaPMC
  2. Anterior Cruciate Ligament (ACL) Reconstruction With Lateral Meniscal Repair With and Without Lateral Extra-articular Tenodesis: A Prospective Comparative Study of Functional and Rotational Outcomes
    Jerin George, Joseph Sajeev, Mevin M Nedumparampil +1
    CureusPeer-reviewedCC BYFull textGeneral medicineEurope PMC
  3. Comparative Effectiveness of Low-Dose Intra-Articular Ozone Therapy for Pain and Functional Outcomes in Patients with Knee Osteoarthritis: A Retrospective Cohort Study [Response to Letter].
    Arzu Dinç Yavaş, Sümeyye Akçay
    Journal of pain researchPeer-reviewedCC BY-NCFull textPharmacology & toxicologyEurope PMC
  4. Robot-assisted navigation combined with a double reverse traction reduction frame for retrograde intramedullary nailing of extra-articular distal femoral fractures: a retrospective comparative cohort study
    Bo Wu, Bing Du, Yuhang Liu +6
    Frontiers in medicinePeer-reviewedCC BYFull textEpidemiology & public healthEurope PMCPMCEurope PMC
  5. Percutaneous endomyocardial ablation as a septal reduction strategy in symptomatic obstructive hypertrophic cardiomyopathy: A 20-year single-center observational experience.
    Aoife Casey, John McCormick, David Keane
    HeartRhythm case reportsPeer-reviewedCC BYFull textCardiovascular medicineEurope PMC
BibTeX
@article{chanda2026functional,
  title = {{Functional outcome of closed reduction and percutaneous multiple K-wire fixation of displaced intra-articular calcaneal fracture}},
  author = {Ashoke Kumar Chanda and Raju Mandal and Sudipta Dasgupta and Tirtharaj Debnath and Rakesh Das and Bibartan Guchait},
  journal = {Greenfort International Journal of Applied Medical Science},
  year = {2026},
  month = jul,
  doi = {10.62046/gijams.2026.v04i04.008},
  url = {https://doi.org/10.62046/gijams.2026.v04i04.008},
  note = {CC BY-NC},
}
RIS
TY  - JOUR
TI  - Functional outcome of closed reduction and percutaneous multiple K-wire fixation of displaced intra-articular calcaneal fracture
AU  - Ashoke Kumar Chanda
AU  - Raju Mandal
AU  - Sudipta Dasgupta
AU  - Tirtharaj Debnath
AU  - Rakesh Das
AU  - Bibartan Guchait
PY  - 2026
DA  - 2026/07/01
JO  - Greenfort International Journal of Applied Medical Science
DO  - 10.62046/gijams.2026.v04i04.008
UR  - https://doi.org/10.62046/gijams.2026.v04i04.008
AB  - Background: Calcaneal fracture, being the most common tarsal bone fracture, accounts upto 65% of the cases, and 2% of all fractures. 75% of calcaneal fractures are intra-articular, which is the most common type of fracture. Displaced intra-articular calcaneal fractures (DIACF) are complex injuries associated with significant morbidity. Minimally invasive fixation seeks to restore the joint congruity while minimizing soft tissue complications seen in open approaches. In our study we evaluated the functional and radiological outcomes of closed reduction and percutaneous multiple K-wire fixation in DIACF.Methods: The study was carried out as a descriptive and prospective study in the Department of Orthopaedics, Calcutta National Medical College, Kolkata, India during the period July 2025 to December 2025. Thirty patients of 20 to 60 years, who underwent surgical fixation for displaced intra-articular calcaneal fracture using multiple K wires were followed up. Functional and radiological outcomes at six months follow up were assessed.Results: In our study of 30 patients with DIACF who underwent minimally invasive surgical fixation with k-wires, the mean final AOFAS score was 82.4 ± 6.7. Böhler angle improved from 8.6° preoperatively to 27.2° at final follow-up; Gissane angle corrected from 141.8° to 122.3°. Excellent-to-good outcomes were observed in 86.7% of patients. Complications occurred in 13.3% of cases, primarily superficial pin-tract infections; no deep infections or hardware failures were noted.Conclusion: Closed reduction and percutaneous K-wire fixation is an effective minimally invasive technique for selected DIACF, providing satisfactory functional recovery and radiographic restoration with low complication rates.
SN  - 3048-6904
SN  - 2584-2420
ER  -