Skip to content
DraconiticResearch
Search Sources API
181,716 studies31 sourcesUpdated 58 min ago
Peer-reviewedCC BY-NCNature and science of sleep

Patient-Performed Neck Encirclement Within the NoSAS Score: Score Availability and Diagnostic Performance in a Tertiary Sleep Centre.

6 affiliations
  1. 1Center for Sleep Medicine, Croix-Rousse Hospital, Hospices Civils De Lyon, Lyon, France.
  2. 2Division of Pulmonary Medicine, Lausanne University Hospital (CHUV) and University of Lausanne, Lausanne, Switzerland.
  3. 3Center for Investigation and Research in Sleep, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland.
  4. 4Lyon Neuroscience Research Center, PAM Team, INSERM U1028 / CNRS UMR 5292 / Lyon 1 University, Lyon, France.
  5. 5Grenoble Alpes University, HP2 Laboratory (Hypoxia Pathophysiology), INSERM U1300, Grenoble, France.
  6. 6Research on Healthcare Performance (RESHAPE), INSERM U1290, Université Claude Bernard Lyon, Lyon, France.

Abstract

Background

Obstructive sleep apnea (OSA) is highly prevalent, and early identification remains a major public health challenge. The NoSAS score is a simple and validated screening tool, incorporating neck circumference >40 cm. However, neck circumference measurement may be inconsistently performed in routine practice. Patient-performed neck encirclement, an equipment-free hand-based maneuver, may represent a pragmatic alternative.Methods

We conducted a retrospective analysis of prospectively collected routine clinical data including 449 consecutive patients referred for suspected OSA in a tertiary sleep center (Lyon, France) between September and December 2025. Neck circumference and Patient-performed manual neck encirclement were assessed at the same anatomical level. Diagnostic performance was evaluated for apnea-hypopnea index (AHI) thresholds ≥15 and ≥30 events·h⁻¹. A modified NoSAS score incorporating patient-performed neck encirclement (NoSAS hand) was compared with the standard score. In paired complete-case comparisons, diagnostic estimates and between-score differences were reported with 95% confidence intervals and McNemar tests.Results

Patient-performed neck encirclement was substantially more available than measured neck circumference (94.0% vs 71.3%) and NoSAS hand was calculable more often than standard NoSAS (91.3% vs 68.8%). In the paired complete-case cohort (n=305), at AHI ≥15/h, sensitivity and specificity differences (NoSAS hand minus standard NoSAS) were 0.0% (95% CI -1.9 to 1.9) and +1.0% (95% CI -2.0 to 5.1), respectively; corresponding differences at AHI ≥30/h were 0.0% (95% CI -2.5 to 2.5) and +0.5% (95% CI -1.6 to 2.7).Conclusions

Patient-performed neck encirclement is a simple, equipment-free alternative to measured neck circumference that substantially improves the feasibility of NoSAS implementation while preserving diagnostic performance. In this tertiary sleep-centre workflow, patient-performed neck encirclement was recorded more often than measured neck circumference and increased NoSAS score availability; paired point estimates of sensitivity and specificity at AHI ≥15/h and ≥30/h differed little between scores.

Related

  1. Diagnostic Performance of Different AI Tools for Chest Radiography: A CT-Anchored Per-Abnormality Analysis in a Tertiary Referral Center.
    Selin Ardalı Düzgün, İlke Taşçı, Atahan Tamtürk +8
    Diagnostics (Basel, Switzerland)Peer-reviewedCC BYFull textEpidemiology & public healthEurope PMC
  2. Acute effects of bench press conditioning performed with different velocity-loss thresholds on punch performance in elite adolescent boxers.
    Penglin Diao, Jinxuan Bao, Xiaoyu Liu +6
    Frontiers in physiologyPeer-reviewedCC BYFull textSurgery & anaesthesiaEurope PMCPMC
  3. Red Cell Distribution Width-to-Platelet Count Ratio as an Early Marker of Severity in Acute Pancreatitis: A Diagnostic Accuracy Study at a Tertiary Care Center
    Sumedha Ghosh, Ramchandra Besra, Pankaj Bodra +7
    CureusPeer-reviewedCC BYFull textGeneral medicineEurope PMC
  4. Low energy availability in recreational high-intensity functional training athletes: associations with health and performance outcomes
    Gabriella Vlattas, Xuewen Wang, Andrew Ortaglia +2
    Frontiers in NutritionPeer-reviewedCC BYFull textSurgery & anaesthesiaDOAJ
  5. Twenty-one years of cutaneous melanoma: stage shift, anatomical patterns and diagnostic trends from a Southern European tertiary center
    Nello Tommasino, Claudia Costa, Alessia Villani +5
    Melanoma ResearchPeer-reviewedCC BY 4.0Full text1 citedEpidemiology & public healthPMC
BibTeX
@article{kassir2026patientperformed,
  title = {{Patient-Performed Neck Encirclement Within the NoSAS Score: Score Availability and Diagnostic Performance in a Tertiary Sleep Centre.}},
  author = {Sarah Kassir and Claudio Rabec and Raphael Heinzer and Christophe Von Garnier and Lina Latreche and Sabrina Hajji and Francois Ricordeau and Emeric Stauffer and Laure Peter-Derex and Pierre Tankéré},
  journal = {Nature and science of sleep},
  year = {2026},
  month = oct,
  doi = {10.2147/nss.s646897},
  url = {https://europepmc.org/article/MED/42921212},
  note = {CC BY-NC},
}
RIS
TY  - JOUR
TI  - Patient-Performed Neck Encirclement Within the NoSAS Score: Score Availability and Diagnostic Performance in a Tertiary Sleep Centre.
AU  - Sarah Kassir
AU  - Claudio Rabec
AU  - Raphael Heinzer
AU  - Christophe Von Garnier
AU  - Lina Latreche
AU  - Sabrina Hajji
AU  - Francois Ricordeau
AU  - Emeric Stauffer
AU  - Laure Peter-Derex
AU  - Pierre Tankéré
PY  - 2026
DA  - 2026/10/19
JO  - Nature and science of sleep
DO  - 10.2147/nss.s646897
UR  - https://europepmc.org/article/MED/42921212
AB  - Background  Obstructive sleep apnea (OSA) is highly prevalent, and early identification remains a major public health challenge. The NoSAS score is a simple and validated screening tool, incorporating neck circumference >40 cm. However, neck circumference measurement may be inconsistently performed in routine practice. Patient-performed neck encirclement, an equipment-free hand-based maneuver, may represent a pragmatic alternative.Methods  We conducted a retrospective analysis of prospectively collected routine clinical data including 449 consecutive patients referred for suspected OSA in a tertiary sleep center (Lyon, France) between September and December 2025. Neck circumference and Patient-performed manual neck encirclement were assessed at the same anatomical level. Diagnostic performance was evaluated for apnea-hypopnea index (AHI) thresholds ≥15 and ≥30 events·h⁻¹. A modified NoSAS score incorporating patient-performed neck encirclement (NoSAS hand) was compared with the standard score. In paired complete-case comparisons, diagnostic estimates and between-score differences were reported with 95% confidence intervals and McNemar tests.Results  Patient-performed neck encirclement was substantially more available than measured neck circumference (94.0% vs 71.3%) and NoSAS hand was calculable more often than standard NoSAS (91.3% vs 68.8%). In the paired complete-case cohort (n=305), at AHI ≥15/h, sensitivity and specificity differences (NoSAS hand minus standard NoSAS) were 0.0% (95% CI -1.9 to 1.9) and +1.0% (95% CI -2.0 to 5.1), respectively; corresponding differences at AHI ≥30/h were 0.0% (95% CI -2.5 to 2.5) and +0.5% (95% CI -1.6 to 2.7).Conclusions  Patient-performed neck encirclement is a simple, equipment-free alternative to measured neck circumference that substantially improves the feasibility of NoSAS implementation while preserving diagnostic performance. In this tertiary sleep-centre workflow, patient-performed neck encirclement was recorded more often than measured neck circumference and increased NoSAS score availability; paired point estimates of sensitivity and specificity at AHI ≥15/h and ≥30/h differed little between scores.
SN  - 1179-1608
ER  -