Single-Pulse Dosimetry for Ultra-High-Dose-Rate X-Ray Pulses Based on Radiation-Induced Acoustic Signals

Abstract

Real-time dosimetry of ultra-high-dose-rate (UHDR) pulsed X-rays remains a major challenge. This proof-of-principle study investigates a dosimetry method for UHDR pulsed X-rays based on radiation-induced acoustic (RA) signals from a thin metal foil. The foil combines efficient X-ray absorption and acoustic resonance, converting deposited dose into acoustic signals with discrete resonant frequencies. Single-pulse measurements were performed at six dose levels spanning approximately 1--40 mGy(Si), with one pulse recorded at each level and instantaneous dose rates reaching the order of 10^6 Gy/s at the highest dose settings. The peak-to-peak amplified transducer-output voltage exhibited a linear relationship with the reference dose measured by thermoluminescent dosimeters (TLDs). These results demonstrate the feasibility of single-pulse acoustic dosimetry under the tested conditions. Furthermore, we establish analytical solutions for radiation-induced acoustic signals in a one-dimensional layered medium in both the time and frequency domains, providing a theoretical basis for signal interpretation and detector optimization.

Related

  1. A single radiation hard pixel detector for proton dosimetry, imaging, energy resolution and beam monitoring
    Nico Frederic Brosda, Stephane Higueret, Nicolas Arbor +7
    HALPreprintarXiv licenceFull textApplied physics & instrumentationBiological & medical physicsHALarXiv
  2. EP09.28 Quality assurance in a national randomized trial of radiation target volume reduction in glioblastoma: results from the contouring and dosimetry dummy run
    D Di Perri, C De Laet, M Lambrecht +28
    Neuro-OncologyPeer-reviewedPublisher termsFull textApplied physics & instrumentationPMC
  3. Towards in vivo photon dosimetry using radiation-sensitive mixed-core ultrasound phase-change contrast agents
    Bram Carlier, Reza Bahrami Gorji, Qingyuan Tan +5
    arXivPreprintarXiv licenceFull textBiological & medical physicsarXiv
  4. Steerable Radiation Forces with Frequency-Detuned Acoustic Metasurfaces
    Sam Keller, Matthew Stein, Ognjen Ilic
    arXivPreprintarXiv licenceFull textApplied physics & instrumentationarXiv
  5. Circulation and operational sparsity of analogue Hawking radiation in rotating acoustic horizons
    Fernando M. Belchior, Joao A. A. S. Reis, Edilberto O. Silva
    arXivPreprintCC BY 4.0Full textGravitation & general relativityarXiv
BibTeX
@misc{han2026singlepulse,
  title = {{Single-Pulse Dosimetry for Ultra-High-Dose-Rate X-Ray Pulses Based on Radiation-Induced Acoustic Signals}},
  author = {Qihang Han and Ke Chen and Chenghao Hua and Haoran Chen and Lili Ding and Changhui Li and Xiaoping Ouyang and Chenhui Wang and Wei Chen and Wenjun Ma},
  howpublished = {arXiv},
  year = {2026},
  month = nov,
  doi = {10.48550/arxiv.2611.27772},
  eprint = {2611.27772},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2611.27772},
}
RIS
TY  - UNPB
TI  - Single-Pulse Dosimetry for Ultra-High-Dose-Rate X-Ray Pulses Based on Radiation-Induced Acoustic Signals
AU  - Qihang Han
AU  - Ke Chen
AU  - Chenghao Hua
AU  - Haoran Chen
AU  - Lili Ding
AU  - Changhui Li
AU  - Xiaoping Ouyang
AU  - Chenhui Wang
AU  - Wei Chen
AU  - Wenjun Ma
PY  - 2026
DA  - 2026/11/20
PB  - arXiv
DO  - 10.48550/arxiv.2611.27772
UR  - https://arxiv.org/abs/2611.27772
AB  - Real-time dosimetry of ultra-high-dose-rate (UHDR) pulsed X-rays remains a major challenge. This proof-of-principle study investigates a dosimetry method for UHDR pulsed X-rays based on radiation-induced acoustic (RA) signals from a thin metal foil. The foil combines efficient X-ray absorption and acoustic resonance, converting deposited dose into acoustic signals with discrete resonant frequencies. Single-pulse measurements were performed at six dose levels spanning approximately 1--40 mGy(Si), with one pulse recorded at each level and instantaneous dose rates reaching the order of 10^6 Gy/s at the highest dose settings. The peak-to-peak amplified transducer-output voltage exhibited a linear relationship with the reference dose measured by thermoluminescent dosimeters (TLDs). These results demonstrate the feasibility of single-pulse acoustic dosimetry under the tested conditions. Furthermore, we establish analytical solutions for radiation-induced acoustic signals in a one-dimensional layered medium in both the time and frequency domains, providing a theoretical basis for signal interpretation and detector optimization.
ER  -