Abstract
Real-time dosimetry of ultra-high-dose-rate (UHDR) pulsed X-rays remains a major challenge. This proof-of-principle study investigates a dosimetry method for UHDR pulsed X-rays based on radiation-induced acoustic (RA) signals from a thin metal foil. The foil combines efficient X-ray absorption and acoustic resonance, converting deposited dose into acoustic signals with discrete resonant frequencies. Single-pulse measurements were performed at six dose levels spanning approximately 1--40 mGy(Si), with one pulse recorded at each level and instantaneous dose rates reaching the order of 10^6 Gy/s at the highest dose settings. The peak-to-peak amplified transducer-output voltage exhibited a linear relationship with the reference dose measured by thermoluminescent dosimeters (TLDs). These results demonstrate the feasibility of single-pulse acoustic dosimetry under the tested conditions. Furthermore, we establish analytical solutions for radiation-induced acoustic signals in a one-dimensional layered medium in both the time and frequency domains, providing a theoretical basis for signal interpretation and detector optimization.
Related
- A single radiation hard pixel detector for proton dosimetry, imaging, energy resolution and beam monitoring
- EP09.28 Quality assurance in a national randomized trial of radiation target volume reduction in glioblastoma: results from the contouring and dosimetry dummy run
- Towards in vivo photon dosimetry using radiation-sensitive mixed-core ultrasound phase-change contrast agents
- Steerable Radiation Forces with Frequency-Detuned Acoustic Metasurfaces
- Circulation and operational sparsity of analogue Hawking radiation in rotating acoustic horizons
BibTeX
@misc{han2026singlepulse,
title = {{Single-Pulse Dosimetry for Ultra-High-Dose-Rate X-Ray Pulses Based on Radiation-Induced Acoustic Signals}},
author = {Qihang Han and Ke Chen and Chenghao Hua and Haoran Chen and Lili Ding and Changhui Li and Xiaoping Ouyang and Chenhui Wang and Wei Chen and Wenjun Ma},
howpublished = {arXiv},
year = {2026},
month = nov,
doi = {10.48550/arxiv.2611.27772},
eprint = {2611.27772},
archivePrefix = {arXiv},
url = {https://arxiv.org/abs/2611.27772},
}
RIS
TY - UNPB
TI - Single-Pulse Dosimetry for Ultra-High-Dose-Rate X-Ray Pulses Based on Radiation-Induced Acoustic Signals
AU - Qihang Han
AU - Ke Chen
AU - Chenghao Hua
AU - Haoran Chen
AU - Lili Ding
AU - Changhui Li
AU - Xiaoping Ouyang
AU - Chenhui Wang
AU - Wei Chen
AU - Wenjun Ma
PY - 2026
DA - 2026/11/20
PB - arXiv
DO - 10.48550/arxiv.2611.27772
UR - https://arxiv.org/abs/2611.27772
AB - Real-time dosimetry of ultra-high-dose-rate (UHDR) pulsed X-rays remains a major challenge. This proof-of-principle study investigates a dosimetry method for UHDR pulsed X-rays based on radiation-induced acoustic (RA) signals from a thin metal foil. The foil combines efficient X-ray absorption and acoustic resonance, converting deposited dose into acoustic signals with discrete resonant frequencies. Single-pulse measurements were performed at six dose levels spanning approximately 1--40 mGy(Si), with one pulse recorded at each level and instantaneous dose rates reaching the order of 10^6 Gy/s at the highest dose settings. The peak-to-peak amplified transducer-output voltage exhibited a linear relationship with the reference dose measured by thermoluminescent dosimeters (TLDs). These results demonstrate the feasibility of single-pulse acoustic dosimetry under the tested conditions. Furthermore, we establish analytical solutions for radiation-induced acoustic signals in a one-dimensional layered medium in both the time and frequency domains, providing a theoretical basis for signal interpretation and detector optimization.
ER -