Skip to content
DraconiticResearch
Search Sources API
203,234 studies31 sourcesUpdated 11 min ago
PreprintCC BY 4.0arXiv

Magnonic cavity-enhanced quantum magnetometry with nitrogen-vacancy centre ensembles

Abstract

Nitrogen-vacancy (NV) centre ensembles are leading room-temperature magnetometers, but their sensitivity is usually extracted from a single resonance and relies on external microwave and bias-field hardware. This work proposes a chip-scale NV magnetometer built around a one-dimensional YIG/CoFeB magnonic crystal, in which a single structural defect forms a passive magnonic cavity and integrated permanent magnets supply the bias field. Micromagnetic simulations show a defect-localised spin-wave mode at 2.910 GHz inside the 2.5-3.0 GHz magnonic band gap, 40 MHz from the NV zero-field splitting, with a band structure that matches an independent plane-wave calculation. A Tavis-Cummings/Lindblad model in which the microwave reaches the NV ensemble through this mode predicts a hyperfine-resolved optically detected magnetic resonance spectrum that is strong only within the mode linewidth, and a dispersive homodyne response with one steep edge per 14N hyperfine line. The master-equation solutions agree with the closed-form homodyne steady state (R2 > 0.9999) and with an approximate analytic ODMR theory (peak positions within 0.012 MHz). For a critically coupled readout with room-temperature electronics, combining the three edges gives a projected sensitivity of 93 pT/√(Hz), a √3-fold gain over the best single edge. Mapping the sensitivity against the NV-magnon coupling reveals an optimum near gens/2π≈ 0.2-$0.4$ MHz, where it reaches 72 pT/√(Hz) for a 0.64 MHz spin linewidth and 19 pT/√(Hz) for 0.17 MHz, with thermal limits of 6.6 and 1.7 pT/√(Hz). The antenna-mode coupling, the NV-magnon coupling and the spin linewidth are therefore the main design levers.

Related

  1. Nitrogen Vacancy Centers in Diamond for Quantum Biosensing: Magnetometry Techniques, Platforms and Applications
    Sirsendu Ghosal, Umakant Prajapati, Sachin Negi +3
    arXivPreprintCC BY 4.0Full textOptics & photonicsQuantum physics & quantum informationarXiv
  2. Constraint-Traceable Liquid-Nitrogen Dewar Design for Low-Noise HTS-SQUID Magnetometry
    Xinmin Shi, Bingke Xiang, Lingtong Hou +9
    arXivPreprintarXiv licenceFull textApplied physics & instrumentationCondensed matterarXiv
  3. Continuous-wave AC magnetometry up to hundreds of megahertz using nitrogen-vacancy centers under a strong transverse magnetic field
    Ryusei Okaniwa, Rui Suzuki, Yuichiro Matsuzaki +2
    arXivPreprintCC BY-NC-ND 4.0Full textQuantum physics & quantum informationarXiv
  4. Enhanced Atomic Magnetometry with a Pinched Spin State
    Tingxuan Guo, Xiangyu Li, Yang Li +1
    arXivPreprintarXiv licenceFull textQuantum physics & quantum informationarXiv
  5. Gate Synthesis in Dephasing-Limited Nitrogen-Vacancy Ensembles
    Ankita Chakravarty, Arnaud Carignan-Dugas, Eva Dupont-Ferrier +1
    arXivPreprintCC BY-SA 4.0Full textQuantum physics & quantum informationarXiv
BibTeX
@misc{kumar2026magnonic,
  title = {{Magnonic cavity-enhanced quantum magnetometry with nitrogen-vacancy centre ensembles}},
  author = {Nikhil Kumar},
  howpublished = {arXiv},
  year = {2026},
  month = oct,
  doi = {10.48550/arxiv.2610.11350},
  eprint = {2610.11350},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2610.11350},
  note = {CC BY 4.0},
}
RIS
TY  - UNPB
TI  - Magnonic cavity-enhanced quantum magnetometry with nitrogen-vacancy centre ensembles
AU  - Nikhil Kumar
PY  - 2026
DA  - 2026/10/08
PB  - arXiv
DO  - 10.48550/arxiv.2610.11350
UR  - https://arxiv.org/abs/2610.11350
AB  - Nitrogen-vacancy (NV) centre ensembles are leading room-temperature magnetometers, but their sensitivity is usually extracted from a single resonance and relies on external microwave and bias-field hardware. This work proposes a chip-scale NV magnetometer built around a one-dimensional YIG/CoFeB magnonic crystal, in which a single structural defect forms a passive magnonic cavity and integrated permanent magnets supply the bias field. Micromagnetic simulations show a defect-localised spin-wave mode at 2.910 GHz inside the 2.5-3.0 GHz magnonic band gap, 40 MHz from the NV zero-field splitting, with a band structure that matches an independent plane-wave calculation. A Tavis-Cummings/Lindblad model in which the microwave reaches the NV ensemble through this mode predicts a hyperfine-resolved optically detected magnetic resonance spectrum that is strong only within the mode linewidth, and a dispersive homodyne response with one steep edge per ^14N hyperfine line. The master-equation solutions agree with the closed-form homodyne steady state (R^2 > 0.9999) and with an approximate analytic ODMR theory (peak positions within 0.012 MHz). For a critically coupled readout with room-temperature electronics, combining the three edges gives a projected sensitivity of 93 pT/√(Hz), a √3-fold gain over the best single edge. Mapping the sensitivity against the NV-magnon coupling reveals an optimum near g_ens/2π≈ 0.2-$0.4$ MHz, where it reaches 72 pT/√(Hz) for a 0.64 MHz spin linewidth and 19 pT/√(Hz) for 0.17 MHz, with thermal limits of 6.6 and 1.7 pT/√(Hz). The antenna-mode coupling, the NV-magnon coupling and the spin linewidth are therefore the main design levers.
ER  -