Integrated intelligent smoke management system: integrating electrostatic precipitation with PID-controlled air recirculation for charcoal-grill restaurant kitchens

Abstract

Charcoal-grill restaurants can contribute to localized air pollution through emissions of particulate matter, including PM₂.₅ and PM₁₀, particularly in small kitchens with limited ventilation. This study developed and experimentally evaluated an intelligent smoke management system integrating a dual-stage electrostatic precipitator (ESP), PID-controlled multi-pass air recirculation, and a compact smoke-capture hood for small charcoal-grill restaurants. The prototype was tested in an enclosed kitchen with a volume of 25 m ³ under Single-pass and Recirculation operating modes at airflow velocities of 2 and 3 m/s using six paired experimental runs (n = 6). System performance was evaluated based on PM₂.₅ and PM₁₀ removal efficiency, particulate removal rate, Equivalent Clean Air Delivery Rate (CADRₑq), and electrical energy consumption. The results showed that the Recirculation mode at an airflow velocity of 3 m/s achieved the highest particulate-removal efficiencies, reaching 95.15% for PM₂.₅ and 95.50% for PM₁₀. These values were significantly higher than those obtained under the corresponding Single-pass condition (p < 0.001). Under this operating condition, the measured average system-level electrical power was 68.2 W, corresponding to an energy consumption of 11.4 Wh per 10-min experimental cycle. The equivalent Clean Air Delivery Rate (CADRₑq), estimated from the experimentally derived airflow and measured particulate-removal efficiency, was approximately 813.1 m ³ /h for PM₂.₅ and 816.1 m ³ /h for PM₁₀. These findings demonstrate that integrating a dual-stage ESP with PID-controlled multi-pass air recirculation improved particulate-removal performance under the specific experimental conditions investigated. However, because the system was evaluated at a single test site using six matched experimental runs, further validation across different kitchen environments and cooking loads, together with direct ozone and VOC measurements and long-term operational assessment, is required before broader commercial applicability can be established.

Related

  1. Toward Intelligent Chemical Mechanical Polishing: Integrating Multiscale Modeling and Machine Learning
    Materials (Basel, Switzerland)Peer-reviewedCC BYFull textEurope PMC
  2. Toward Intelligent Fatigue Management of Welded Metal Sheet Structures by Integrating Simulation, Sensing, and Machine Learning
    Yingjin Cheng, Zongwu Niu, Yujia Yang +1
    Materials (Basel, Switzerland)Peer-reviewedCC BYFull textEurope PMC
  3. Intelligent fine-grained classification of tunnel surrounding rock mass by integrating tunnel face point clouds and measurement-while-drilling data
    Li Liu, Yang Li, Yunfei Ding +3
    Scientific ReportsPeer-reviewedCC BY-NC-ND 4.0NatureCrossref
  4. Freestanding PZT Films for Integrated Wearable Sensing and Intelligent Acoustic Recognition
    Hailong Pan, Zhichao Xu, Rongxiao Liu +4
    Advanced SciencePeer-reviewedCC BYFull textEurope PMC
  5. An automata-machine learning integrated framework for intelligent mental health diagnostics
    Lokesh Pawar, Rohit Bajaj, Yohannes Mengist +4
    Scientific ReportsPeer-reviewedCC BY-NC-ND 4.0Full textCrossref
BibTeX
@article{chumkhuntod2026integrated,
  title = {{Integrated intelligent smoke management system: integrating electrostatic precipitation with PID-controlled air recirculation for charcoal-grill restaurant kitchens}},
  author = {Sutipong Chumkhuntod and Anantakul Intarapadung and Karin Kandananond},
  journal = {Scientific Reports},
  year = {2026},
  month = oct,
  doi = {10.1038/s41598-026-75793-6},
  url = {https://www.nature.com/articles/s41598-026-75793-6},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Integrated intelligent smoke management system: integrating electrostatic precipitation with PID-controlled air recirculation for charcoal-grill restaurant kitchens
AU  - Sutipong Chumkhuntod
AU  - Anantakul Intarapadung
AU  - Karin Kandananond
PY  - 2026
DA  - 2026/10/21
JO  - Scientific Reports
DO  - 10.1038/s41598-026-75793-6
UR  - https://www.nature.com/articles/s41598-026-75793-6
AB  - Charcoal-grill restaurants can contribute to localized air pollution through emissions of particulate matter, including PM₂.₅ and PM₁₀, particularly in small kitchens with limited ventilation. This study developed and experimentally evaluated an intelligent smoke management system integrating a dual-stage electrostatic precipitator (ESP), PID-controlled multi-pass air recirculation, and a compact smoke-capture hood for small charcoal-grill restaurants. The prototype was tested in an enclosed kitchen with a volume of 25 m ³ under Single-pass and Recirculation operating modes at airflow velocities of 2 and 3 m/s using six paired experimental runs (n = 6). System performance was evaluated based on PM₂.₅ and PM₁₀ removal efficiency, particulate removal rate, Equivalent Clean Air Delivery Rate (CADRₑq), and electrical energy consumption. The results showed that the Recirculation mode at an airflow velocity of 3 m/s achieved the highest particulate-removal efficiencies, reaching 95.15% for PM₂.₅ and 95.50% for PM₁₀. These values were significantly higher than those obtained under the corresponding Single-pass condition (p < 0.001). Under this operating condition, the measured average system-level electrical power was 68.2 W, corresponding to an energy consumption of 11.4 Wh per 10-min experimental cycle. The equivalent Clean Air Delivery Rate (CADRₑq), estimated from the experimentally derived airflow and measured particulate-removal efficiency, was approximately 813.1 m ³ /h for PM₂.₅ and 816.1 m ³ /h for PM₁₀. These findings demonstrate that integrating a dual-stage ESP with PID-controlled multi-pass air recirculation improved particulate-removal performance under the specific experimental conditions investigated. However, because the system was evaluated at a single test site using six matched experimental runs, further validation across different kitchen environments and cooking loads, together with direct ozone and VOC measurements and long-term operational assessment, is required before broader commercial applicability can be established.
SN  - 2045-2322
ER  -