Transpedicular Placement of a 3D-Printed Porous Titanium Cage for Anterior Column Reconstruction in Osteoporotic Vertebral Collapse: A Case Series
- 1Department of Neurosurgery, Korea University Anam Hospital, Korea University College of Medicine, Seoul, Korea .
Abstract
Objective: In frail elderly patients with Kümmell disease or osteoporotic burst fractures, cement augmentation relieves pain and partially restores height but achieves neither durable load-bearing support nor biological integration of the anterior column, whereas corpectomy carries substantial morbidity. We evaluated transpedicular placement of a three-dimensional (3D)-printed porous titanium cage for anterior column reconstruction.
Methods: We retrospectively reviewed six consecutive patients (mean age 69.3 years; 2 men, 4 women) who underwent transpedicular intrabody insertion of a 3D-printed porous titanium cage with posterior fixation for osteoporotic vertebral collapse. Three had Kümmell disease and three had osteoporotic burst fractures, including one proximal junctional failure. Back and leg pain (visual analog scale, VAS), disability (Oswestry Disability Index, ODI), and segmental angle were assessed.
Results: At a mean follow-up of 19.0 months (range, 12–36 months), mean back-pain VAS improved from 6.8 to 2.3 and ODI from 69.3% to 26.3%. Mean segmental kyphosis was corrected from 36.8° to 11.9° immediately after surgery and maintained at 15.8°. All neurological deficits improved, including complete recovery of sphincter function in one patient with conus medullaris syndrome. One severely osteoporotic patient showed loss of correction from cage subsidence; no symptomatic hardware failure occurred.
Conclusion: Transpedicular 3D-printed porous titanium cage augmentation appears to be a feasible, less-invasive option for anterior column reconstruction in osteoporotic vertebral collapse; however, these preliminary findings from a small, heterogeneous series require confirmation in larger, longer studies.
Related
- Effects of percutaneous kyphoplasty with concomitant postural reduction in the treatment of acute osteoporotic vertebral compression fractures
- Unsupervised machine learning for clinical risk subtyping and re-fracture risk analysis in osteoporotic vertebral compression fractures.
- Correlation Between Paravertebral Muscles Degeneration and Spinopelvic Parameters in Patients With Osteoporotic Vertebral Compression Fractures.
- Comparison of Two Puncture Approaches in Robot-Assisted Percutaneous Kyphoplasty for Upper Thoracic Osteoporotic Vertebral Compression Fractures.
- Percutaneous Vertebroplasty for Painful Osteoporotic Vertebral Compression Fractures: A Retrospective Comparative Study of a Negative Pressure‐Guided Technique
BibTeX
@article{kim2026transpedicular,
title = {{Transpedicular Placement of a 3D-Printed Porous Titanium Cage for Anterior Column Reconstruction in Osteoporotic Vertebral Collapse: A Case Series}},
author = {Donghyun Kim and Junseok W Hur and Younggyu Oh and Sungjae An and Ho-jun Chae and Subum Lee},
journal = {Korean Journal of Neurotrauma},
year = {2026},
month = oct,
doi = {10.13004/kjnt.2026.22.e46},
url = {https://doi.org/10.13004/kjnt.2026.22.e46},
note = {CC BY-NC 4.0},
}
RIS
TY - JOUR
TI - Transpedicular Placement of a 3D-Printed Porous Titanium Cage for Anterior Column Reconstruction in Osteoporotic Vertebral Collapse: A Case Series
AU - Donghyun Kim
AU - Junseok W Hur
AU - Younggyu Oh
AU - Sungjae An
AU - Ho-jun Chae
AU - Subum Lee
PY - 2026
DA - 2026/10/14
JO - Korean Journal of Neurotrauma
DO - 10.13004/kjnt.2026.22.e46
UR - https://doi.org/10.13004/kjnt.2026.22.e46
AB - Objective: In frail elderly patients with Kümmell disease or osteoporotic burst fractures, cement augmentation relieves pain and partially restores height but achieves neither durable load-bearing support nor biological integration of the anterior column, whereas corpectomy carries substantial morbidity. We evaluated transpedicular placement of a three-dimensional (3D)-printed porous titanium cage for anterior column reconstruction. Methods: We retrospectively reviewed six consecutive patients (mean age 69.3 years; 2 men, 4 women) who underwent transpedicular intrabody insertion of a 3D-printed porous titanium cage with posterior fixation for osteoporotic vertebral collapse. Three had Kümmell disease and three had osteoporotic burst fractures, including one proximal junctional failure. Back and leg pain (visual analog scale, VAS), disability (Oswestry Disability Index, ODI), and segmental angle were assessed. Results: At a mean follow-up of 19.0 months (range, 12–36 months), mean back-pain VAS improved from 6.8 to 2.3 and ODI from 69.3% to 26.3%. Mean segmental kyphosis was corrected from 36.8° to 11.9° immediately after surgery and maintained at 15.8°. All neurological deficits improved, including complete recovery of sphincter function in one patient with conus medullaris syndrome. One severely osteoporotic patient showed loss of correction from cage subsidence; no symptomatic hardware failure occurred. Conclusion: Transpedicular 3D-printed porous titanium cage augmentation appears to be a feasible, less-invasive option for anterior column reconstruction in osteoporotic vertebral collapse; however, these preliminary findings from a small, heterogeneous series require confirmation in larger, longer studies.
SN - 2234-8999
SN - 2288-2243
ER -