Abstract

Measurements leveraging the intrinsic photon-number resolution of Superconducting Nanostrip Single-Photon Detectors (SNSPDs) have recently gained traction due to the simplicity of the detector design. Intrinsic photon-number measurement schemes using SNSPDs encode the photon-number information in picosecond signal timing; these systems thus require high bandwidth readout and sensitive electrical measurement equipment. We show a cryogenic electronic circuit operating close to the SNSPD in the cryostat, which can isolate single-photon detection events directly from the SNSPD signal. This reduces the latency of the photon-number readout to (13.9 ± 0.3) ns, which enables feedforward operations based on intrinsic photon-number measurements with low latency.

Related

  1. Axion polarimetry with parametric readout: photon-number conversion and sensitivity limits
    Antonio Capolupo, Gabriele Pisacane, Raoul Serao
    arXivPreprintCC BY 4.0Full textHigh-energy & particle physicsOptics & photonicsarXiv
  2. Real-Time Single-Pixel Imaging via Exploiting Temporal Mixing: A Unified Calibration and Composite Readout Framework
    Jing-Sen Li, En-Rui Zhang, Kan-Xu Jia +4
    arXivPreprintarXiv licenceFull textOptics & photonicsarXiv
  3. Photon-Number Discrimination from Increasing Time-of-Arrival Separation in Wide Superconducting Microstrip Single-Photon Detectors
    Hsin-Yeh Wu, Shu-Xiao Liu, Boris Tuchming +9
    arXivPreprintarXiv licenceFull textApplied physics & instrumentationHigh-energy & particle physicsarXivHAL
  4. Single-Shot Fidelity Reveals Hard and Soft Limits: A Universal Yardstick for Photon-Number-Resolving Detectors
    Tetsuya Tsuruta, Akio Yoshizawa, Daiji Fukuda
    arXivPreprintarXiv licenceFull textOptics & photonicsQuantum physics & quantum informationarXiv
  5. Quartet state of the neutral nitrogen-vacancy center in diamond and optimized spin readout under near-infrared two-photon excitation
    Nikoletta Jegenyes, Pál Maák, Vladimir Verkhovlyuk +4
    arXivPreprintCC BY 4.0Full textQuantum physics & quantum informationarXiv
BibTeX
@misc{lamberty2026realtime,
  title = {{Real-Time Cryo-CMOS Photon-Number Readout from a Single SNSPD}},
  author = {Niklas Lamberty and Dileep V. Reddy and Aishi Barua and Martin J. Stevens and Tim J. Bartley},
  howpublished = {arXiv},
  year = {2026},
  month = nov,
  doi = {10.48550/arxiv.2611.34135},
  eprint = {2611.34135},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2611.34135},
}
RIS
TY  - UNPB
TI  - Real-Time Cryo-CMOS Photon-Number Readout from a Single SNSPD
AU  - Niklas Lamberty
AU  - Dileep V. Reddy
AU  - Aishi Barua
AU  - Martin J. Stevens
AU  - Tim J. Bartley
PY  - 2026
DA  - 2026/11/25
PB  - arXiv
DO  - 10.48550/arxiv.2611.34135
UR  - https://arxiv.org/abs/2611.34135
AB  - Measurements leveraging the intrinsic photon-number resolution of Superconducting Nanostrip Single-Photon Detectors (SNSPDs) have recently gained traction due to the simplicity of the detector design. Intrinsic photon-number measurement schemes using SNSPDs encode the photon-number information in picosecond signal timing; these systems thus require high bandwidth readout and sensitive electrical measurement equipment. We show a cryogenic electronic circuit operating close to the SNSPD in the cryostat, which can isolate single-photon detection events directly from the SNSPD signal. This reduces the latency of the photon-number readout to (13.9 ± 0.3) ns, which enables feedforward operations based on intrinsic photon-number measurements with low latency.
ER  -