Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 46 min ago
Peer-reviewedCC BY 4.0The British Journal of Radiology

Determination of institute-specific CTV-to-PTV prostate margins using the 2020 BIR IGRT geometric uncertainty guidelines for a conventional linear accelerator

Abstract

Objectives: A multitude of differing clinical practice exists for prostate radiotherapy, this includes dose prescription, planning methods, asymmetric margins and the presence, or not, of fiducial markers. Institute specific CTV-to-PTV margins expansion is desirable for optimum treatment of patients. Margins can be determined by assessing geometric errors inherent in radiotherapy.

Methods: The institutional CTV-to-PTV margins for fiducial-free prostate treatments are calculated based on the BIR 2020 methodology derived from the van Herk formulism. Systematic (Σ_tot) and random (σ_tot) errors including delineation, matching and technical accuracy were measured locally while rotational, deformation and intra-fraction errors were quantified from the literature. Σtot and σtot and the penumbral width (σp) are combined with statistical parameters (α) and (β) to calculate the institutional CTV-to-PTV margin expansion (M) for prostate treatments.

Results: An anisotropic CTV-to-PTV margin expansion for prostate EBRT was calculated. The resulting CTV-to-PTV margin was 4 mm left/right, 7.5 mm superior, 7 mm inferior, 6 mm anterior and 5.5 mm posterior, rounded to the nearest 0.5 mm.

Conclusions: Systematic errors contributed substantially to the overall margin particularly due to the magnitude of delineation errors. The margin calculated was smaller than the previously set institutional margin and ensures coverage of the PTV by the 95% isodose for 90% of prostate treatments at our center.

Advances in knowledge: Institute specific margins for prostate radiotherapy on a linear accelerator are provided. These are calculated using the BIR 2020 methodology of CTV-PTV margin calculation.

Related

  1. Integration of Retrieval-Augmented Generation for Knowledge Access in the ELBE Accelerator Control System
    Najmeh Mirian
    arXivPreprintCC BY 4.0Full textApplied physics & instrumentationComputational physicsarXiv
  2. A pathway to improve Nb3Sn for SRF accelerator cavities via Zr inclusion
    M. Tripathi, M. S. Shakel, J. Lee +3
    arXivPreprintCC BY 4.0Full textApplied physics & instrumentationCondensed matterarXiv
  3. Influence of gating and drift correction on prostate cancer treatment margins on a 1.5 T magnetic resonance linear accelerator☆
    Nienke D. Sijtsema, Guus Grimbergen, Eline N. de Groot-van Breugel +2
    Physics and Imaging in Radiation OncologyPeer-reviewedCC BY 4.0Full textApplied physics & instrumentationPMC
  4. Electron Dynamics in a Wakefield Accelerator Driven by Laser Pulses Carrying Orbital Angular Momentum
    Q. Qian, M. Li, Y. Ma +21
    arXivPreprintCC BY 4.0Full textPlasma physicsarXiv
  5. Report of the National Lab Accelerator Study Group for a Muon Collider
    S. Gourlay, C. Mitchell, E. Nanni +5
    arXivPreprintCC BY 4.0Full textApplied physics & instrumentationarXiv
BibTeX
@article{moran2026determination,
  title = {{Determination of institute-specific CTV-to-PTV prostate margins using the 2020 BIR IGRT geometric uncertainty guidelines for a conventional linear accelerator}},
  author = {Michael Moran and Michael Roche and Muhammad F Jamaluddin and Ciara A Lyons and Christopher Walker and Orla McKivitt and Séan M O’Cathail},
  journal = {The British Journal of Radiology},
  year = {2026},
  month = aug,
  doi = {10.1093/bjr/tqag187},
  url = {https://doi.org/10.1093/bjr/tqag187},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Determination of institute-specific CTV-to-PTV prostate margins using the 2020 BIR IGRT geometric uncertainty guidelines for a conventional linear accelerator
AU  - Michael Moran
AU  - Michael Roche
AU  - Muhammad F Jamaluddin
AU  - Ciara A Lyons
AU  - Christopher Walker
AU  - Orla McKivitt
AU  - Séan M O’Cathail
PY  - 2026
DA  - 2026/08/13
JO  - The British Journal of Radiology
DO  - 10.1093/bjr/tqag187
UR  - https://doi.org/10.1093/bjr/tqag187
AB  - Objectives: A multitude of differing clinical practice exists for prostate radiotherapy, this includes dose prescription, planning methods, asymmetric margins and the presence, or not, of fiducial markers. Institute specific CTV-to-PTV margins expansion is desirable for optimum treatment of patients. Margins can be determined by assessing geometric errors inherent in radiotherapy.  Methods: The institutional CTV-to-PTV margins for fiducial-free prostate treatments are calculated based on the BIR 2020 methodology derived from the van Herk formulism. Systematic (Σ_tot) and random (σ_tot) errors including delineation, matching and technical accuracy were measured locally while rotational, deformation and intra-fraction errors were quantified from the literature. Σtot and σtot and the penumbral width (σp) are combined with statistical parameters (α) and (β) to calculate the institutional CTV-to-PTV margin expansion (M) for prostate treatments.  Results: An anisotropic CTV-to-PTV margin expansion for prostate EBRT was calculated. The resulting CTV-to-PTV margin was 4 mm left/right, 7.5 mm superior, 7 mm inferior, 6 mm anterior and 5.5 mm posterior, rounded to the nearest 0.5 mm.  Conclusions: Systematic errors contributed substantially to the overall margin particularly due to the magnitude of delineation errors. The margin calculated was smaller than the previously set institutional margin and ensures coverage of the PTV by the 95% isodose for 90% of prostate treatments at our center.  Advances in knowledge: Institute specific margins for prostate radiotherapy on a linear accelerator are provided. These are calculated using the BIR 2020 methodology of CTV-PTV margin calculation.
SN  - 0007-1285
SN  - 1748-880X
ER  -