Influence of gating and drift correction on prostate cancer treatment margins on a 1.5 T magnetic resonance linear accelerator☆

  1. 1Department of Radiation Oncology, Division of Imaging & Oncology, University Medical Center Utrecht, Utrecht, the Netherlands
  2. 2Department of Radiotherapy, Erasmus MC Cancer Institute, University Medical Center Rotterdam, Rotterdam, the Netherlands

Abstract

In this study, intra-fraction motion management using gating and baseline shift corrections on a 1.5 T magnetic resonance linear accelerator was evaluated in 93 prostate cancer patients. Motion tracks were analyzed to assess the frequency, size and duration of baseline shift corrections and derive planning target volume (PTV) margins. Baseline shift corrections were required in 89.2% of patients, with a range of 0–6 corrections per fraction. The resulting PTV margins were 1.2 mm left-right, and 2.3 mm anterior-posterior and cranial-caudal. Because these values were conservatively estimated, a 2 mm isotropic PTV margin was clinically implemented without increasing treatment time.

Related

  1. Six-year data from three magnetic resonance-guided radiotherapy systems demonstrate long-term stability of linear accelerator quality assurance
    Guido C. Hilgers, Simon J. Woodings, Thomas A. Foppen +4
    Physics and Imaging in Radiation OncologyPeer-reviewedCC BY 4.0Full textApplied physics & instrumentationPMCEurope PMC
  2. Determination of institute-specific CTV-to-PTV prostate margins using the 2020 BIR IGRT geometric uncertainty guidelines for a conventional linear accelerator
    Michael Moran, Michael Roche, Muhammad F Jamaluddin +4
    The British Journal of RadiologyPeer-reviewedCC BY 4.0Full textApplied physics & instrumentationPMC
  3. Dosimetric impact of baseline shift plan in a magnetic resonance linear accelerator according to target motion and plan characteristics.
    Shohei Tanaka, Noriyuki Kadoya, Yoshiyuki Takahashi +9
    Journal of applied clinical medical physicsPeer-reviewedCC BYFull textApplied physics & instrumentationEurope PMC
  4. Dosimetric and Treatment Delivery Efficiency Comparison of Two Ring-gantry Linear Accelerator Platforms for Liver Stereotactic Body Radiotherapy
    Srikanth Guduru, Rohith Singareddy, N. V. N. Madhusudhana Sresty +2
    Journal of Medical PhysicsPeer-reviewedCC BY-NC-SAFull textApplied physics & instrumentationDOAJ
  5. Resonance correction to time-dependent finite-size effects in Effective Field Theory of binary black hole inspiral
    Shani Avitan, Ram Brustein
    arXivPreprintCC BY 4.0Full textGravitation & general relativityarXiv
BibTeX
@article{sijtsema2026influence,
  title = {{Influence of gating and drift correction on prostate cancer treatment margins on a 1.5 T magnetic resonance linear accelerator☆}},
  author = {Nienke D. Sijtsema and Guus Grimbergen and Eline N. de Groot-van Breugel and Jochem R.N. van der Voort van Zyp and Johannes C.J. de Boer},
  journal = {Physics and Imaging in Radiation Oncology},
  year = {2026},
  month = nov,
  doi = {10.1016/j.phro.2026.101127},
  url = {https://doi.org/10.1016/j.phro.2026.101127},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Influence of gating and drift correction on prostate cancer treatment margins on a 1.5 T magnetic resonance linear accelerator☆
AU  - Nienke D. Sijtsema
AU  - Guus Grimbergen
AU  - Eline N. de Groot-van Breugel
AU  - Jochem R.N. van der Voort van Zyp
AU  - Johannes C.J. de Boer
PY  - 2026
DA  - 2026/11/11
JO  - Physics and Imaging in Radiation Oncology
DO  - 10.1016/j.phro.2026.101127
UR  - https://doi.org/10.1016/j.phro.2026.101127
AB  - In this study, intra-fraction motion management using gating and baseline shift corrections on a 1.5 T magnetic resonance linear accelerator was evaluated in 93 prostate cancer patients. Motion tracks were analyzed to assess the frequency, size and duration of baseline shift corrections and derive planning target volume (PTV) margins. Baseline shift corrections were required in 89.2% of patients, with a range of 0–6 corrections per fraction. The resulting PTV margins were 1.2 mm left-right, and 2.3 mm anterior-posterior and cranial-caudal. Because these values were conservatively estimated, a 2 mm isotropic PTV margin was clinically implemented without increasing treatment time.
SN  - 2405-6316
ER  -