Usefulness of Adaptive Complex Signal Average Diffusion-weighted MR Imaging of the Abdomen

Abstract

PURPOSE: To evaluate the clinical feasibility and quantitative performance of adaptive complex signal average (ACSA) diffusion-weighted imaging (DWI) in abdominal MRI and to compare ACSA DWI with conventional non-ACSA DWI in terms of signal intensity (SI), SNR, apparent diffusion coefficient (ADC), signal intensity difference ratio (SIDR), and lesion contrast across different numbers of excitations (NEX). METHODS: This retrospective study included 82 patients who underwent free-breathing abdominal DWI on a 3T system between January and July 2025. ACSA DWI was reconstructed from the same raw data as non-ACSA DWI using a combination of adaptive averaging and complex-domain averaging. ROIs were placed in the liver, pancreas, left adrenal gland, and spinal muscles to measure SI, SNR, and ADC. SIDR and inter-lobar right-left (R-L) ratio in SI and ADC were calculated at NEX 2, 3, and 4. For 37 patients with non-cystic hepatic nodules, lesion SI, ADC, contrast ratio, and contrast-to-noise ratio (CNR) were assessed. RESULTS: ACSA DWI significantly increased SI and SNR in motion-prone organs, including the lateral hepatic segment, pancreas, and left adrenal gland, at all NEX levels (P < 0.05). ADC values in abdominal parenchymal organs and hepatic nodules were lower with ACSA DWI, reflecting the noise-floor suppression and adaptive average effects. R-L SI and ADC ratios were significantly different and were closer to 1 in ACSA DWI, indicating improved hepatic signal homogeneity. Lesion SI, contrast ratio, and CNR were significantly higher with ACSA DWI, enhancing nodule conspicuity. CONCLUSION: ACSA DWI improves signal uniformity, SNR, and lesion contrast while maintaining reasonable ADC quantification. Without prolonging scan time or modifying acquisition parameters, ACSA provides a robust, clinically feasible post-processing technique for enhancing both image quality and quantitative reliability in abdominal DWI.

Related

  1. Usefulness of the C-reactive Protein Level as a Substitute for the Erythrocyte Sedimentation Rate when Calculating the BACES Score of Patients with Mycobacterium Avium Complex Pulmonary Disease
    Shunnosuke Tanaka, Atsuhito Ushiki, Masanobu Kimoto +4
    Internal MedicinePeer-reviewedCC BY-NC-NDFull textEpidemiology & public healthJ-STAGE
  2. Interobserver agreement of non-parallel transmission technology zoomed-diffusion-weighted imaging (DWI) for ordinal biparametric Vesical Imaging-Reporting and Data System (VI-RADS)-based scoring in bladder cancer lesions ≥1 cm
    Dianyu Wang, Zhenming Zhang, Yanjing Wang +7
    Quantitative imaging in medicine and surgeryPeer-reviewedCC BY-NC-NDFull textMedical imaging & radiologyEurope PMC
  3. Multi-b-value diffusion-weighted imaging-based habitat imaging for preoperative prediction of histological grade and prognosis in soft tissue sarcoma: focusing on intratumoral heterogeneity
    Chunlian Chen, Jie Zhou, Zesheng Zhang +10
    Quantitative imaging in medicine and surgeryPeer-reviewedCC BY-NC-NDFull textMedical imaging & radiologyEurope PMC
  4. Diffusion-weighted magnetic resonance imaging and immunohistochemistry in Epstein-Barr virus-positive diffuse large B-cell lymphoma of the maxilla: a rare case report
    Yoriaki Kanri, Yuko Watarai, Ryo Mizuhashi +2
    The Egyptian Journal of OtolaryngologyPeer-reviewedCC BYFull textOncologyDOAJ
  5. Development of a Dedicated Prostate Phantom for Technical Evaluation of Diffusion-weighted MR Imaging Sequences
    Kazunori Ohashi, Shigehiro Soh, Yoshiomi Sato +6
    Magnetic Resonance in Medical SciencesPeer-reviewedCC BYFull textMedical imaging & radiologyJ-STAGE
BibTeX
@article{matsukuma2026usefulness,
  title = {{Usefulness of Adaptive Complex Signal Average Diffusion-weighted MR Imaging of the Abdomen}},
  author = {Miwa Matsukuma and Masahiro Tanabe and Mayumi Higashi and Masatoshi Yamane and Masahiro Abe and Ryutaro Yano and Haruki Furutani and Jo Ishii and Katsuyoshi Ito},
  journal = {Magnetic Resonance in Medical Sciences},
  year = {2026},
  month = jul,
  doi = {10.2463/mrms.mp.2026-0009},
  url = {https://www.jstage.jst.go.jp/article/mrms/25/4/25_mp.2026-0009/_article},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Usefulness of Adaptive Complex Signal Average Diffusion-weighted MR Imaging of the Abdomen
AU  - Miwa Matsukuma
AU  - Masahiro Tanabe
AU  - Mayumi Higashi
AU  - Masatoshi Yamane
AU  - Masahiro Abe
AU  - Ryutaro Yano
AU  - Haruki Furutani
AU  - Jo Ishii
AU  - Katsuyoshi Ito
PY  - 2026
DA  - 2026/07/25
JO  - Magnetic Resonance in Medical Sciences
DO  - 10.2463/mrms.mp.2026-0009
UR  - https://www.jstage.jst.go.jp/article/mrms/25/4/25_mp.2026-0009/_article
AB  - PURPOSE: To evaluate the clinical feasibility and quantitative performance of adaptive complex signal average (ACSA) diffusion-weighted imaging (DWI) in abdominal MRI and to compare ACSA DWI with conventional non-ACSA DWI in terms of signal intensity (SI), SNR, apparent diffusion coefficient (ADC), signal intensity difference ratio (SIDR), and lesion contrast across different numbers of excitations (NEX). METHODS: This retrospective study included 82 patients who underwent free-breathing abdominal DWI on a 3T system between January and July 2025. ACSA DWI was reconstructed from the same raw data as non-ACSA DWI using a combination of adaptive averaging and complex-domain averaging. ROIs were placed in the liver, pancreas, left adrenal gland, and spinal muscles to measure SI, SNR, and ADC. SIDR and inter-lobar right-left (R-L) ratio in SI and ADC were calculated at NEX 2, 3, and 4. For 37 patients with non-cystic hepatic nodules, lesion SI, ADC, contrast ratio, and contrast-to-noise ratio (CNR) were assessed. RESULTS: ACSA DWI significantly increased SI and SNR in motion-prone organs, including the lateral hepatic segment, pancreas, and left adrenal gland, at all NEX levels (P < 0.05). ADC values in abdominal parenchymal organs and hepatic nodules were lower with ACSA DWI, reflecting the noise-floor suppression and adaptive average effects. R-L SI and ADC ratios were significantly different and were closer to 1 in ACSA DWI, indicating improved hepatic signal homogeneity. Lesion SI, contrast ratio, and CNR were significantly higher with ACSA DWI, enhancing nodule conspicuity. CONCLUSION: ACSA DWI improves signal uniformity, SNR, and lesion contrast while maintaining reasonable ADC quantification. Without prolonging scan time or modifying acquisition parameters, ACSA provides a robust, clinically feasible post-processing technique for enhancing both image quality and quantitative reliability in abdominal DWI.
SN  - 1880-2206
SN  - 1347-3182
ER  -