Within-Device Exposure-Setting and Voxel-Size Changes in CBCT Alveolar Bone Measurement for Implant Planning: A Systematic Review.
5 affiliations
- 1Faculty of Medicine and Health Sciences (Dentistry), University of Barcelona, 08907 L'Hospitalet de Llobregat, Spain.
- 2Faculty of Dentistry, ADEMA University School, 07009 Palma, Spain.
- 3Department of Odontostomatology, Faculty of Medicine and Health Sciences, School of Dentistry, Campus of Bellvitge, University of Barcelona, Barcelona Dental Hospital [HOUB], 08970 Barcelona, Spain.
- 4Service of the Medical-Surgical Area of Dentistry Hospital, University of Barcelona, 08907 Barcelona, Spain.
- 5Department of Diagnostic Sciences and Oral Biology and Periodontology, College of Dentistry, King Khalid University, Abha 62521, Saudi Arabia.
Abstract
Background
This review examined whether within-device exposure-setting or nominal voxel-size changes in cone-beam computed tomography (CBCT) affect linear alveolar bone measurements for implant planning, separating accuracy from agreement.Methods
Database-specific search strategies and retrieval counts are reported for PubMed/MEDLINE, Ovid Embase, Scopus, and Web of Science Core Collection. Study selection is presented in the updated PRISMA flow diagram. The reported International Prospective Register of Systematic Reviews (PROSPERO) identifier is CRD420261361509. Studies were grouped by outcome, protocol contrast, and experimental model. The Quality Assessment Tool for In Vitro Studies (QUIN) appraisal was performed by one reviewer. A revision-stage source and analysis-unit audit led to withdrawal of the planned inverse-variance meta-analyses and their ±0.5 mm equivalence claims; structured study-level synthesis was used instead.Results
Eight studies addressed linear measurements; two additional reports were retained only as methodological context. Seven linear-measurement studies compared protocols within a device, and one compared different devices. All were experimental. In one five-skull study, mean absolute errors were 0.50, 0.46, and 0.51 mm at 40, 20, and 7 s, respectively. A cadaver study reported mean absolute errors of approximately 1.10-1.20 mm. Small mean between-protocol differences sometimes coexisted with impaired anatomical visibility. Repeated observations were not equivalent to independent specimens, and several required sampling variances could not be reconstructed.Conclusions
Selected within-device protocol changes may preserve average measurements under controlled experimental conditions. The evidence does not establish statistical equivalence, interchangeability of protocol classes, or clinical safety near critical anatomy. Validation in living patients is needed before broad implementation.
Related
- Artificial Intelligence Versus Manual Measurement of Spinopelvic Sagittal Parameters Across Preoperative, Postoperative, and Instrumented Spines: A Systematic Review of Diagnostic Accuracy, Failure Rates, and Inferred Surgical Planning Implications.
- Secondary Pulmonary Alveolar Proteinosis after Allogeneic Hematopoietic Stem Cell Transplantation in the Setting of an Respiratory Syncytial Virus Infection: A Case Report
- Charting the future: A multi-setting medical chart study of advance care planning in Parkinson's disease and atypical Parkinsonism
- DIFFUSE ALVEOLAR HEMORRHAGE AFTER ALLOGENEIC HEMATOPOIETIC CELL TRANSPLANTATION: A DIAGNOSTIC AND THERAPEUTIC CHALLENGE IN THE SETTING OF CONCURRENT INFECTION
- Pediatric Kidney Transplantation in the Setting of Inferior Vena Cava Thrombosis or Atresia: A Single-Center Case Series and Considerations for Operative Planning.
BibTeX
@article{elkattan2026withindevice,
title = {{Within-Device Exposure-Setting and Voxel-Size Changes in CBCT Alveolar Bone Measurement for Implant Planning: A Systematic Review.}},
author = {Ahmed Samir Elkattan and Mónica Piña-DAbreu and Pere Riutord-Sbert and Mónica Blázquez-Hinarejos and José López-López and Hassan Ahmed Assiri and Angel Arturo López González},
journal = {Tomography (Ann Arbor, Mich.)},
year = {2026},
month = nov,
doi = {10.3390/tomography12110162},
url = {https://europepmc.org/article/MED/43083652},
note = {CC BY},
}
RIS
TY - JOUR
TI - Within-Device Exposure-Setting and Voxel-Size Changes in CBCT Alveolar Bone Measurement for Implant Planning: A Systematic Review.
AU - Ahmed Samir Elkattan
AU - Mónica Piña-DAbreu
AU - Pere Riutord-Sbert
AU - Mónica Blázquez-Hinarejos
AU - José López-López
AU - Hassan Ahmed Assiri
AU - Angel Arturo López González
PY - 2026
DA - 2026/11/09
JO - Tomography (Ann Arbor, Mich.)
DO - 10.3390/tomography12110162
UR - https://europepmc.org/article/MED/43083652
AB - Background This review examined whether within-device exposure-setting or nominal voxel-size changes in cone-beam computed tomography (CBCT) affect linear alveolar bone measurements for implant planning, separating accuracy from agreement.Methods Database-specific search strategies and retrieval counts are reported for PubMed/MEDLINE, Ovid Embase, Scopus, and Web of Science Core Collection. Study selection is presented in the updated PRISMA flow diagram. The reported International Prospective Register of Systematic Reviews (PROSPERO) identifier is CRD420261361509. Studies were grouped by outcome, protocol contrast, and experimental model. The Quality Assessment Tool for In Vitro Studies (QUIN) appraisal was performed by one reviewer. A revision-stage source and analysis-unit audit led to withdrawal of the planned inverse-variance meta-analyses and their ±0.5 mm equivalence claims; structured study-level synthesis was used instead.Results Eight studies addressed linear measurements; two additional reports were retained only as methodological context. Seven linear-measurement studies compared protocols within a device, and one compared different devices. All were experimental. In one five-skull study, mean absolute errors were 0.50, 0.46, and 0.51 mm at 40, 20, and 7 s, respectively. A cadaver study reported mean absolute errors of approximately 1.10-1.20 mm. Small mean between-protocol differences sometimes coexisted with impaired anatomical visibility. Repeated observations were not equivalent to independent specimens, and several required sampling variances could not be reconstructed.Conclusions Selected within-device protocol changes may preserve average measurements under controlled experimental conditions. The evidence does not establish statistical equivalence, interchangeability of protocol classes, or clinical safety near critical anatomy. Validation in living patients is needed before broad implementation.
SN - 2379-1381
SN - 2379-139X
ER -