Skip to content
DraconiticResearch
Search Sources API
194,230 studies31 sourcesUpdated 53 min ago
Peer-reviewedCC BY-NC-NDBMC cardiovascular disorders

Comparative efficacy of esophageal protection strategies during radiofrequency atrial fibrillation ablation: a systematic review and network meta-analysis of randomized trials.

7 affiliations
  1. 1Cardiac Electrophysiology Research Center, Rajaie Cardiovascular Institute, Tehran, Iran.
  2. 2Congenital Heart Diseases Research Center, Rajaie Cardiovascular Institute, Tehran, Iran.
  3. 3Echocardiography Research Center, Rajaie Cardiovascular Institute, Tehran, Iran.
  4. 4School of Medicine, Tehran University of Medical Sciences, Tehran, Iran.
  5. 5Cardiovascular Imaging Research Center, Rajaie Cardiovascular Institute, Tehran, Iran.
  6. 6Department of Internal Medicine III, University Hospital Halle (Saale), Martin-Luther University Halle-Wittenberg, Halle (Saale), Germany.
  7. 7Cardiac Electrophysiology Research Center, Rajaie Cardiovascular Institute, Tehran, Iran. [email protected].

Abstract

Background

Esophageal thermal injury remains a clinically significant complication of radiofrequency catheter ablation for atrial fibrillation (AF), with endoscopically detected esophageal lesions (EDELs) occurring in up to 10-15% of cases and atrio-esophageal fistula carrying high mortality. Multiple protective strategies have been proposed; however, their comparative efficacy remains uncertain.Methods

We conducted a systematic review and network meta-analysis of randomized controlled trials evaluating esophageal protection strategies during AF ablation. PubMed, Web of Science, Scopus, and ClinicalTrials.gov were searched from inception through August 7, 2026. Parallel-group randomized trials in adult patients undergoing radiofrequency ablation were included. The primary outcome was incidence of EDEL. A frequentist random-effects network meta-analysis was performed, with treatment hierarchy assessed using P-scores. Risk of bias and certainty of evidence were evaluated using the Cochrane RoB 2 and CINeMA frameworks, respectively.Results

Twenty-five randomized controlled trials involving approximately 2,500 patients were included in the systematic review. Twelve trials involving 1,077 patients contributed to the connected network meta-analysis. Mechanical esophageal deviation combined with luminal esophageal temperature monitoring (LET) had the most favorable point estimate compared with no dedicated protection (OR, 0.27; 95% CI, 0.02-3.05) and achieved the highest P-score (0.861). The rankogram estimated a 58% probability of ranking first. Visualization-guided strategies also showed a favorable point estimate (OR, 0.48; 95% CI, 0.08-3.09), whereas LET alone and active cooling did not demonstrate significant reductions in EDEL. Directly, mechanical deviation plus LET significantly reduced the odds of EDEL compared with single-sensor LET (OR, 0.13; 95% CI, 0.04-0.41). Seven randomized trials involving 990 patients showed no significant association between higher- versus standard-power ablation and EDEL (OR, 1.19; 95% CI, 0.56-2.54), with no observed heterogeneity (I² = 0%). Network heterogeneity was moderate (I² = 46.9%), with no significant evidence of network inconsistency or publication bias.Conclusions

No single esophageal protection strategy completely eliminates the risk of thermal injury during AF ablation. Mechanical esophageal deviation combined with LET demonstrated the most favorable overall ranking, while visualization-guided strategies also showed a potentially beneficial signal. In contrast, LET or cooling alone did not reliably reduce EDEL incidence. However, overall confidence in the evidence is constrained by small trial samples and reliance on surrogate outcomes. Larger, contemporary trials are needed to confirm clinical benefits and assess the impact on rare but catastrophic complications.Clinical trial number

Not Applicable.

Related

  1. Comparative effectiveness of neoadjuvant treatment strategies and predictors of pathological complete response in locally advanced esophageal squamous cell carcinoma: a real-world retrospective cohort study
    Xiaoli Yuan, Yuying Liang, Tianlin Han +8
    Frontiers in OncologyPeer-reviewedCC BY 4.0Full textSurgery & anaesthesiaCrossrefPMC
  2. Predictive Value of Left Atrial Strain Combined with Low-Voltage Substrate for Recurrence After Radiofrequency Catheter Ablation in Persistent Atrial Fibrillation
    Diagnostics (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
  3. Radiofrequency ablation with a conventional solid tip catheter in contact with an implantable cardioverter-defibrillator coil causing inadvertent ventricular fibrillation.
    Michael R Manogue
    HeartRhythm case reportsPeer-reviewedCC BY-NC-NDFull textCardiovascular medicineEurope PMC
  4. The modified APPLE score for predicting atrial fibrillation recurrence in patients with hypertension undergoing radiofrequency ablation
    Luosha Wang, Peng Chang, Xin Ma +4
    Scientific ReportsPeer-reviewedCC BY-NC-ND 4.0Full textCardiovascular medicineCrossref
  5. Pulsed Field Versus Radiofrequency Ablation For Repeat Ablation of Atrial Fibrillation: Evaluation of Outcomes
    V. Patel, C. Ashur, J. Adewumi +8
    medRxivPreprintAll rights reservedFull textCardiovascular medicinemedRxiv
BibTeX
@article{ramezani2026comparative,
  title = {{Comparative efficacy of esophageal protection strategies during radiofrequency atrial fibrillation ablation: a systematic review and network meta-analysis of randomized trials.}},
  author = {Akam Ramezani and Naghmeh Kian and Amirmohammad Sharafi and Fatemeh Yousefimoghaddam and Arya Khezrpour and Amir Ghaffari Jolfayi and Arash Arya and Majid Haghjoo},
  journal = {BMC cardiovascular disorders},
  year = {2026},
  month = oct,
  doi = {10.1186/s12872-026-06836-z},
  url = {https://europepmc.org/article/MED/42972224},
  note = {CC BY-NC-ND},
}
RIS
TY  - JOUR
TI  - Comparative efficacy of esophageal protection strategies during radiofrequency atrial fibrillation ablation: a systematic review and network meta-analysis of randomized trials.
AU  - Akam Ramezani
AU  - Naghmeh Kian
AU  - Amirmohammad Sharafi
AU  - Fatemeh Yousefimoghaddam
AU  - Arya Khezrpour
AU  - Amir Ghaffari Jolfayi
AU  - Arash Arya
AU  - Majid Haghjoo
PY  - 2026
DA  - 2026/10/14
JO  - BMC cardiovascular disorders
DO  - 10.1186/s12872-026-06836-z
UR  - https://europepmc.org/article/MED/42972224
AB  - Background  Esophageal thermal injury remains a clinically significant complication of radiofrequency catheter ablation for atrial fibrillation (AF), with endoscopically detected esophageal lesions (EDELs) occurring in up to 10-15% of cases and atrio-esophageal fistula carrying high mortality. Multiple protective strategies have been proposed; however, their comparative efficacy remains uncertain.Methods  We conducted a systematic review and network meta-analysis of randomized controlled trials evaluating esophageal protection strategies during AF ablation. PubMed, Web of Science, Scopus, and ClinicalTrials.gov were searched from inception through August 7, 2026. Parallel-group randomized trials in adult patients undergoing radiofrequency ablation were included. The primary outcome was incidence of EDEL. A frequentist random-effects network meta-analysis was performed, with treatment hierarchy assessed using P-scores. Risk of bias and certainty of evidence were evaluated using the Cochrane RoB 2 and CINeMA frameworks, respectively.Results  Twenty-five randomized controlled trials involving approximately 2,500 patients were included in the systematic review. Twelve trials involving 1,077 patients contributed to the connected network meta-analysis. Mechanical esophageal deviation combined with luminal esophageal temperature monitoring (LET) had the most favorable point estimate compared with no dedicated protection (OR, 0.27; 95% CI, 0.02-3.05) and achieved the highest P-score (0.861). The rankogram estimated a 58% probability of ranking first. Visualization-guided strategies also showed a favorable point estimate (OR, 0.48; 95% CI, 0.08-3.09), whereas LET alone and active cooling did not demonstrate significant reductions in EDEL. Directly, mechanical deviation plus LET significantly reduced the odds of EDEL compared with single-sensor LET (OR, 0.13; 95% CI, 0.04-0.41). Seven randomized trials involving 990 patients showed no significant association between higher- versus standard-power ablation and EDEL (OR, 1.19; 95% CI, 0.56-2.54), with no observed heterogeneity (I² = 0%). Network heterogeneity was moderate (I² = 46.9%), with no significant evidence of network inconsistency or publication bias.Conclusions  No single esophageal protection strategy completely eliminates the risk of thermal injury during AF ablation. Mechanical esophageal deviation combined with LET demonstrated the most favorable overall ranking, while visualization-guided strategies also showed a potentially beneficial signal. In contrast, LET or cooling alone did not reliably reduce EDEL incidence. However, overall confidence in the evidence is constrained by small trial samples and reliance on surrogate outcomes. Larger, contemporary trials are needed to confirm clinical benefits and assess the impact on rare but catastrophic complications.Clinical trial number  Not Applicable.
SN  - 1471-2261
ER  -