Imageless Robotic-Assisted Kinematic Alignment Total Knee Arthroplasty: Surgical Technique and Preliminary Outcomes of an Initial Single-Surgeon Case Series
- 1Department of Orthopaedics, Traumatology and Rehabilitation, International Islamic University Malaysia, Kuantan 25200, Pahang, Malaysia
- 2Department of Orthopaedics, Singapore General Hospital, Singapore Health Services, Singapore 169608, Singapore
- 3Duke-NUS Medical School, National University of Singapore, Singapore 169857, Singapore
Abstract
Background: Robotic assistance may improve the precision of kinematic alignment total knee arthroplasty (KA-rTKA), but immediate recovery after imageless KA-rTKA remains insufficiently described. This study describes an early institutional experience with imageless robotic workflow for KA-rTKA and provides preliminary postoperative day 1 (POD1) recovery and six-month functional outcomes. Methods: This retrospective single-center study included 50 knees in 50 consecutive unique patients who underwent KA-rTKA, using the VELYS Robotic-Assisted Solution between January and June 2024. POD1 outcomes included range of motion (ROM), pain, and walking distance. Six-month outcomes included ROM, Knee Society Function Score (KSFS), Knee Society Knee Score (KSKS), Oxford Knee Score (OKS), and SF-36 Physical and Mental Component Summary scores (PCS and MCS). Minimum clinically important difference (MCID) attainment was assessed. Results: On POD1, mean ROM was 71.9° ± 21.8°, resting pain was 1.0 ± 1.4, movement-related pain was 3.8 ± 2.2, and walking distance was 19.0 ± 17.6 m. At six months, KSFS improved from 52.8 ± 20.9 to 72.1 ± 24.6, KSKS from 38.1 ± 15.4 to 83.3 ± 18.4, OKS (lower scores indicate better function) from 35.7 ± 9.0 to 20.1 ± 7.0, PCS from 31.7 ± 7.7 to 46.1 ± 10.2, and MCS from 51.4 ± 11.8 to 58.5 ± 9.6 (all p < 0.001). MCID achievement was high across knee-specific outcomes, at 94%, 80%, and 90% for KSKS, KSFS, and OKS respectively. Conclusions: Imageless KA-rTKA was associated with favorable immediate postoperative recovery and clinically meaningful six-month improvements in this single-arm series. Larger comparative studies with longer follow-up are required to determine whether these early improvements translate into superior long-term outcomes.
Related
- Revision of Unicompartmental Knee Arthroplasty to Total Knee Arthroplasty Using the CORITM Imageless System: A Step-By-Step Surgical Technique.
- Higher body mass index is associated with lower patient‐reported outcomes, whereas alignment and soft‐tissue balance remain comparable following imageless robotic‐assisted functional alignment total knee arthroplasty: A retrospective analysis from the Brescia Knee Research Group
- Clinical outcomes of posterior-stabilized versus cruciate-retaining ANTHEM total knee arthroplasty using imageless robotic-assisted personalized alignment: a retrospective comparative cohort study.
- Kinematic Alignment in Total Knee Arthroplasty: Unresolved Challenges and Barriers to Overcome for Universal Application
- Kinematic Alignment Using Conventional Mechanical-Alignment Instruments with 3D-Printed Tibial Recut Guide Versus Manual Mechanical Alignment in Total Knee Arthroplasty: An IPTW-Adjusted Comparative Cohort Study
BibTeX
@article{kow2026imageless,
title = {{Imageless Robotic-Assisted Kinematic Alignment Total Knee Arthroplasty: Surgical Technique and Preliminary Outcomes of an Initial Single-Surgeon Case Series}},
author = {Ren Yi Kow and Yong Ng and Jeremy Tze En Lim and Darren Keng Jin Tay and Hee Nee Pang and Seng Jin Yeo and Ming Han Lincoln Liow},
journal = {Journal of Clinical Medicine},
year = {2026},
month = nov,
doi = {10.3390/jcm15228851},
url = {https://www.mdpi.com/2077-0383/15/22/8851},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Imageless Robotic-Assisted Kinematic Alignment Total Knee Arthroplasty: Surgical Technique and Preliminary Outcomes of an Initial Single-Surgeon Case Series
AU - Ren Yi Kow
AU - Yong Ng
AU - Jeremy Tze En Lim
AU - Darren Keng Jin Tay
AU - Hee Nee Pang
AU - Seng Jin Yeo
AU - Ming Han Lincoln Liow
PY - 2026
DA - 2026/11/01
JO - Journal of Clinical Medicine
DO - 10.3390/jcm15228851
UR - https://www.mdpi.com/2077-0383/15/22/8851
AB - Background: Robotic assistance may improve the precision of kinematic alignment total knee arthroplasty (KA-rTKA), but immediate recovery after imageless KA-rTKA remains insufficiently described. This study describes an early institutional experience with imageless robotic workflow for KA-rTKA and provides preliminary postoperative day 1 (POD1) recovery and six-month functional outcomes. Methods: This retrospective single-center study included 50 knees in 50 consecutive unique patients who underwent KA-rTKA, using the VELYS Robotic-Assisted Solution between January and June 2024. POD1 outcomes included range of motion (ROM), pain, and walking distance. Six-month outcomes included ROM, Knee Society Function Score (KSFS), Knee Society Knee Score (KSKS), Oxford Knee Score (OKS), and SF-36 Physical and Mental Component Summary scores (PCS and MCS). Minimum clinically important difference (MCID) attainment was assessed. Results: On POD1, mean ROM was 71.9° ± 21.8°, resting pain was 1.0 ± 1.4, movement-related pain was 3.8 ± 2.2, and walking distance was 19.0 ± 17.6 m. At six months, KSFS improved from 52.8 ± 20.9 to 72.1 ± 24.6, KSKS from 38.1 ± 15.4 to 83.3 ± 18.4, OKS (lower scores indicate better function) from 35.7 ± 9.0 to 20.1 ± 7.0, PCS from 31.7 ± 7.7 to 46.1 ± 10.2, and MCS from 51.4 ± 11.8 to 58.5 ± 9.6 (all p < 0.001). MCID achievement was high across knee-specific outcomes, at 94%, 80%, and 90% for KSKS, KSFS, and OKS respectively. Conclusions: Imageless KA-rTKA was associated with favorable immediate postoperative recovery and clinically meaningful six-month improvements in this single-arm series. Larger comparative studies with longer follow-up are required to determine whether these early improvements translate into superior long-term outcomes.
SN - 2077-0383
ER -