Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 20 min ago
Peer-reviewedCC BY 4.0International Journal of Molecular Sciences

Critical-Point-Anchored Hybrid Helmholtz Equations of State: Calibration Trade-Offs and Limits for Eight Reference Fluids

4 affiliations
  1. 1Escuela de Ingeniería Química, Pontificia Universidad Católica de Valparaíso, Valparaíso 2340000, Chile
  2. 2Doctorado en Industria Inteligente, Facultad de Ingeniería, Pontificia Universidad Católica de Valparaíso, Valparaíso 2340000, Chile
  3. 3CONICET-IIM, Facultad de Ingeniería, Universidad Nacional de San Juan, Av. Libertador General San Martín 1109 Oeste, San Juan J5400ARL, Argentina
  4. 4Escuela de Ingeniería en Construcción y Transporte, Pontificia Universidad Católica de Valparaíso, Valparaíso 2340000, Chile

Abstract

A two-parameter cubic equation of state (EoS) fixes its critical compressibility factor: Peng–Robinson (PR) with constants fitted to saturation data reaches only the surface Zc=0.3074 and misplaces the critical volume of every real fluid. On a per-fluid basis, we calibrate a hybrid residual Helmholtz energy in which PR is an exact limit and a small neural correction is trained with the classical critical conditions as an anchor. One documented run of 276 units covered three synthetic cubic truths, held-out temperatures, eight fluids described by reference EoS of the National Institute of Standards and Technology (NIST), a sweep of the anchor weight and a noise study. For the eight fluids the anchor reduced the mean absolute relative error (MARE) in Vc from 14.74% (refitted PR) to 0.32% and the root mean square relative error (RMSRE) in saturation pressure from 5.51% to 1.05%; against the unanchored hybrid, whose RMSRE was 0.46%, the cost was 0.59 percentage points, within a one-point margin for seven fluids. PR with reference constants kept a lower pressure RMSRE (0.83%) and a liquid density RMSRE 20 times larger. Without the anchor the inferred Vc varied by up to 22% across initialisations. A revision run harmonised the ammonia anchor with the EoS behind its data, which removed a 3.7% offset in Vc without lowering the pressure cost, and traced low-temperature solver failures to the solver. Learned critical isotherms are flatter in the pressure–density plane; dilute and supercritical gas states are not constrained (up to 41% pressure error at 2Tc), so the models apply to saturated states only. Prediction for unseen molecules is not tested.

Related

  1. Structure of human hephaestin reveals a homodimer anchored to the cell membrane
    Ce Liang, Ming Zhou, Yaping Pan
    bioRxivPreprintAll rights reservedFull textGeneral biochemistrybioRxivPMC
  2. Effect of Ca2+ and Mg2+ on the conformational dynamics of membrane-anchored Bcl-xL
    Quynh Nguyen, J. Alfredo Freites, Alexey S. Ladokhin +1
    Biochimica et biophysica acta. BiomembranesPeer-reviewedLicence not statedFull textMolecular biology & gene regulationPMC
  3. Experimentally anchored, MHC-agnostic prediction of immunogenicity and cytokine release.
    Vikarn Bhakri, Zachary Walters, Ronnie Wei +1
    Antibody therapeuticsPeer-reviewedCC BY-NCFull textMolecular biology & gene regulationEurope PMCPMC
  4. Type-Strain-Anchored Phylogenomics Reveals Taxonomic Discordance and Functional Variation in Agrobacterium
    Maria S. Filatova, Peter V. Evseev, Alexander N. Ignatov +3
    International Journal of Molecular SciencesPeer-reviewedCC BY 4.0Full textMolecular biology & gene regulationCrossrefEurope PMC
  5. Where the magnet sits sets the sign of the scaling law: membrane-anchored versus intracellular magnetic actuation of cells
    Y. Xia, L. Yin, A. Lin +2
    bioRxivPreprintCC BYFull textBiophysicsbioRxiv
BibTeX
@article{robles2026criticalpointanchored,
  title = {{Critical-Point-Anchored Hybrid Helmholtz Equations of State: Calibration Trade-Offs and Limits for Eight Reference Fluids}},
  author = {Pedro Robles and Luis Rios and Vanesa Bazan and Luis Rojas-Valdivia and José García},
  journal = {International Journal of Molecular Sciences},
  year = {2026},
  month = nov,
  doi = {10.3390/ijms272310720},
  url = {https://www.mdpi.com/1422-0067/27/23/10720},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Critical-Point-Anchored Hybrid Helmholtz Equations of State: Calibration Trade-Offs and Limits for Eight Reference Fluids
AU  - Pedro Robles
AU  - Luis Rios
AU  - Vanesa Bazan
AU  - Luis Rojas-Valdivia
AU  - José García
PY  - 2026
DA  - 2026/11/26
JO  - International Journal of Molecular Sciences
DO  - 10.3390/ijms272310720
UR  - https://www.mdpi.com/1422-0067/27/23/10720
AB  - A two-parameter cubic equation of state (EoS) fixes its critical compressibility factor: Peng–Robinson (PR) with constants fitted to saturation data reaches only the surface Zc=0.3074 and misplaces the critical volume of every real fluid. On a per-fluid basis, we calibrate a hybrid residual Helmholtz energy in which PR is an exact limit and a small neural correction is trained with the classical critical conditions as an anchor. One documented run of 276 units covered three synthetic cubic truths, held-out temperatures, eight fluids described by reference EoS of the National Institute of Standards and Technology (NIST), a sweep of the anchor weight and a noise study. For the eight fluids the anchor reduced the mean absolute relative error (MARE) in Vc from 14.74% (refitted PR) to 0.32% and the root mean square relative error (RMSRE) in saturation pressure from 5.51% to 1.05%; against the unanchored hybrid, whose RMSRE was 0.46%, the cost was 0.59 percentage points, within a one-point margin for seven fluids. PR with reference constants kept a lower pressure RMSRE (0.83%) and a liquid density RMSRE 20 times larger. Without the anchor the inferred Vc varied by up to 22% across initialisations. A revision run harmonised the ammonia anchor with the EoS behind its data, which removed a 3.7% offset in Vc without lowering the pressure cost, and traced low-temperature solver failures to the solver. Learned critical isotherms are flatter in the pressure–density plane; dilute and supercritical gas states are not constrained (up to 41% pressure error at 2Tc), so the models apply to saturated states only. Prediction for unseen molecules is not tested.
SN  - 1422-0067
ER  -