Critical-Point-Anchored Hybrid Helmholtz Equations of State: Calibration Trade-Offs and Limits for Eight Reference Fluids
4 affiliations
- 1Escuela de Ingeniería Química, Pontificia Universidad Católica de Valparaíso, Valparaíso 2340000, Chile
- 2Doctorado en Industria Inteligente, Facultad de Ingeniería, Pontificia Universidad Católica de Valparaíso, Valparaíso 2340000, Chile
- 3CONICET-IIM, Facultad de Ingeniería, Universidad Nacional de San Juan, Av. Libertador General San Martín 1109 Oeste, San Juan J5400ARL, Argentina
- 4Escuela de Ingeniería en Construcción y Transporte, Pontificia Universidad Católica de Valparaíso, Valparaíso 2340000, Chile
Abstract
A two-parameter cubic equation of state (EoS) fixes its critical compressibility factor: Peng–Robinson (PR) with constants fitted to saturation data reaches only the surface Zc=0.3074 and misplaces the critical volume of every real fluid. On a per-fluid basis, we calibrate a hybrid residual Helmholtz energy in which PR is an exact limit and a small neural correction is trained with the classical critical conditions as an anchor. One documented run of 276 units covered three synthetic cubic truths, held-out temperatures, eight fluids described by reference EoS of the National Institute of Standards and Technology (NIST), a sweep of the anchor weight and a noise study. For the eight fluids the anchor reduced the mean absolute relative error (MARE) in Vc from 14.74% (refitted PR) to 0.32% and the root mean square relative error (RMSRE) in saturation pressure from 5.51% to 1.05%; against the unanchored hybrid, whose RMSRE was 0.46%, the cost was 0.59 percentage points, within a one-point margin for seven fluids. PR with reference constants kept a lower pressure RMSRE (0.83%) and a liquid density RMSRE 20 times larger. Without the anchor the inferred Vc varied by up to 22% across initialisations. A revision run harmonised the ammonia anchor with the EoS behind its data, which removed a 3.7% offset in Vc without lowering the pressure cost, and traced low-temperature solver failures to the solver. Learned critical isotherms are flatter in the pressure–density plane; dilute and supercritical gas states are not constrained (up to 41% pressure error at 2Tc), so the models apply to saturated states only. Prediction for unseen molecules is not tested.
Related
- Structure of human hephaestin reveals a homodimer anchored to the cell membrane
- Effect of Ca2+ and Mg2+ on the conformational dynamics of membrane-anchored Bcl-xL
- Experimentally anchored, MHC-agnostic prediction of immunogenicity and cytokine release.
- Type-Strain-Anchored Phylogenomics Reveals Taxonomic Discordance and Functional Variation in Agrobacterium
- Where the magnet sits sets the sign of the scaling law: membrane-anchored versus intracellular magnetic actuation of cells
BibTeX
@article{robles2026criticalpointanchored,
title = {{Critical-Point-Anchored Hybrid Helmholtz Equations of State: Calibration Trade-Offs and Limits for Eight Reference Fluids}},
author = {Pedro Robles and Luis Rios and Vanesa Bazan and Luis Rojas-Valdivia and José García},
journal = {International Journal of Molecular Sciences},
year = {2026},
month = nov,
doi = {10.3390/ijms272310720},
url = {https://www.mdpi.com/1422-0067/27/23/10720},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Critical-Point-Anchored Hybrid Helmholtz Equations of State: Calibration Trade-Offs and Limits for Eight Reference Fluids
AU - Pedro Robles
AU - Luis Rios
AU - Vanesa Bazan
AU - Luis Rojas-Valdivia
AU - José García
PY - 2026
DA - 2026/11/26
JO - International Journal of Molecular Sciences
DO - 10.3390/ijms272310720
UR - https://www.mdpi.com/1422-0067/27/23/10720
AB - A two-parameter cubic equation of state (EoS) fixes its critical compressibility factor: Peng–Robinson (PR) with constants fitted to saturation data reaches only the surface Zc=0.3074 and misplaces the critical volume of every real fluid. On a per-fluid basis, we calibrate a hybrid residual Helmholtz energy in which PR is an exact limit and a small neural correction is trained with the classical critical conditions as an anchor. One documented run of 276 units covered three synthetic cubic truths, held-out temperatures, eight fluids described by reference EoS of the National Institute of Standards and Technology (NIST), a sweep of the anchor weight and a noise study. For the eight fluids the anchor reduced the mean absolute relative error (MARE) in Vc from 14.74% (refitted PR) to 0.32% and the root mean square relative error (RMSRE) in saturation pressure from 5.51% to 1.05%; against the unanchored hybrid, whose RMSRE was 0.46%, the cost was 0.59 percentage points, within a one-point margin for seven fluids. PR with reference constants kept a lower pressure RMSRE (0.83%) and a liquid density RMSRE 20 times larger. Without the anchor the inferred Vc varied by up to 22% across initialisations. A revision run harmonised the ammonia anchor with the EoS behind its data, which removed a 3.7% offset in Vc without lowering the pressure cost, and traced low-temperature solver failures to the solver. Learned critical isotherms are flatter in the pressure–density plane; dilute and supercritical gas states are not constrained (up to 41% pressure error at 2Tc), so the models apply to saturated states only. Prediction for unseen molecules is not tested.
SN - 1422-0067
ER -