Background: During CPAP therapy, many modern devices generate an estimated residual AHI (AHI-CPAPflow) based on proprietary airflow algorithms. This may differ from polysomnography (PSG) measured AHI (AHI-PSGgold) for a number of reasons. Although some adult studies have demonstrated moderate agreement between AHI-CPAPflow and AHI-PSGgold, paediatric data remains limited.

Methods: A retrospective observational study of all patients aged <18 years who completed an in-laboratory CPAP titration PSG at our centre between January 2016 and December 2025.

For each case, the AHI-CPAPflow recorded by the CPAP machine during the night of the sleep study will be compared with the AHI-PSGgold reported by the sleep laboratory. Other reported data will include basic demographics, volume of leak, coexisting central sleep apnoea, and CPAP device model/interface.

Data analysis will intend to evaluate agreement between the two measures, using correlation analysis, Bland–Altman analysis, and mean differences and limits of agreement. Subgroup analysis may be performed according to age groups, OSA severity class, CPAP device model, presence of leak, or co-existing central sleep apnoea.

Progress to date: Literature review, study design, and ethics approval have been completed. Data collection of approximately 200 patients is underway.

Intended outcome and impact: We intend to determine if there is agreement between CPAP-derived and PSG-measured AHI in children, and potentially if there are specific patient groups where it is less or more reliable. This would provide valuable insights into the accuracy and clinical utility of AHI-CPAPflow, which may inform follow-up practices, need for repeat PSG’s, and guide ongoing management.

Related

  1. Nasal intermittent positive pressure ventilation versus nasal continuous positive airway pressure as initial respiratory support during minimally invasive surfactant therapy in preterm infants with respiratory distress syndrome: a retrospective real-world cohort study
    Translational pediatricsPeer-reviewedCC BY-NC-NDFull textGeneral medicineEurope PMC
  2. Short-term multidimensional effects of continuous positive airway pressure in patients with obstructive sleep apnea-hypopnea syndrome: a single-center retrospective study
    Jie Zhang, Qing Feng, Xiaopei Wang +5
    American Journal of Translational ResearchPeer-reviewedLicence not statedFull textPhysiologyPMC
  3. Factors influencing prognostic outcomes in children on noninvasive continuous positive airway pressure ventilation: A retrospective study
    Peiqing Huo, Minglei Liang, Yuhui Cui +2
    Pakistan Journal of Medical SciencesPeer-reviewedCC BY 3.0Full textGeneral medicinePMC
  4. P017. Agreement between two commonly used pulse oximeters during in-laboratory polysomnography
    J Matthews, O McGuiness, M Milross +5
    Sleep advances : a journal of the Sleep Research SocietyPeer-reviewedCC BY-NC-NDFull textPhysiologyEurope PMCPMC
  5. Seasonal Differences in the Factors Affecting Sleep Restfulness in Patients with Obstructive Sleep Apnea Receiving Continuous Positive Airway Pressure Therapy
    Satoshi Hamada, Hironobu Sunadome, Kimihiko Murase +4
    Internal MedicinePeer-reviewedCC BY-NC-NDFull textPhysiologyJ-STAGE
BibTeX
@article{oneill2026p145,
  title = {{P145. Agreement between continuous positive airway pressure (CPAP) machine-derived apnoea-hyponoea index (AHI) and polysomnography measured AHI in children}},
  author = {D O'Neill and A Tai and T Goddard and R Puvvadi and S Coussens and B Humphries and J Tayler and S Alexander},
  journal = {Sleep advances : a journal of the Sleep Research Society},
  year = {2026},
  month = nov,
  doi = {10.1093/sleepadvances/zpag103.195},
  url = {https://europepmc.org/article/PMC/PMC13783165},
  note = {CC BY-NC-ND},
}
RIS
TY  - JOUR
TI  - P145. Agreement between continuous positive airway pressure (CPAP) machine-derived apnoea-hyponoea index (AHI) and polysomnography measured AHI in children
AU  - D O'Neill
AU  - A Tai
AU  - T Goddard
AU  - R Puvvadi
AU  - S Coussens
AU  - B Humphries
AU  - J Tayler
AU  - S Alexander
PY  - 2026
DA  - 2026/11/01
JO  - Sleep advances : a journal of the Sleep Research Society
DO  - 10.1093/sleepadvances/zpag103.195
UR  - https://europepmc.org/article/PMC/PMC13783165
AB  - Background: During CPAP therapy, many modern devices generate an estimated residual AHI (AHI-CPAPflow) based on proprietary airflow algorithms. This may differ from polysomnography (PSG) measured AHI (AHI-PSGgold) for a number of reasons. Although some adult studies have demonstrated moderate agreement between AHI-CPAPflow and AHI-PSGgold, paediatric data remains limited.  Methods: A retrospective observational study of all patients aged <18 years who completed an in-laboratory CPAP titration PSG at our centre between January 2016 and December 2025.  For each case, the AHI-CPAPflow recorded by the CPAP machine during the night of the sleep study will be compared with the AHI-PSGgold reported by the sleep laboratory. Other reported data will include basic demographics, volume of leak, coexisting central sleep apnoea, and CPAP device model/interface.  Data analysis will intend to evaluate agreement between the two measures, using correlation analysis, Bland–Altman analysis, and mean differences and limits of agreement. Subgroup analysis may be performed according to age groups, OSA severity class, CPAP device model, presence of leak, or co-existing central sleep apnoea.  Progress to date: Literature review, study design, and ethics approval have been completed. Data collection of approximately 200 patients is underway.  Intended outcome and impact: We intend to determine if there is agreement between CPAP-derived and PSG-measured AHI in children, and potentially if there are specific patient groups where it is less or more reliable. This would provide valuable insights into the accuracy and clinical utility of AHI-CPAPflow, which may inform follow-up practices, need for repeat PSG’s, and guide ongoing management.
SN  - 2632-5012
ER  -