Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 18 min ago
Peer-reviewedCC BYBMJ Open

Physiology-based versus guideline-based interpretation of intrapartum cardiotocograph in nulliparous women in term labour at baseline and longitudinally in the prediction of early neonatal outcome: study protocol for a prospective observational study with randomisation of interpretation methods (the ‘PHYSGUIDE’ study)

6 affiliations
  1. 1Obstetrics and Gynaecology, St George’s University Hospitals NHS Foundation Trust, London, UK
  2. 2University of Ferrara, Ferrara, Italy
  3. 3IRCCS Materno Infantile, Maternal and Neonatal Department, IRCCS Burlo Garofolo, Trieste, Italy
  4. 4Azienda Ospedaliero-Universitaria di Cagliari, Dipartimento di Medicina, Cagliari, Italy
  5. 5Policlinico Abano Terme, Abeno Terme, Italy
  6. 6Division of Perinatal Medicine, Policlinico Abano, Abano Terme, Italy

Abstract

Introduction Current clinical guidelines for intrapartum fetal heart rate (FHR) monitoring (1) do not systematically exclude antenatal injuries or the baby’s ability to tolerate labour, thereby risking further injury; (2) do not acknowledge appropriate fetal adaptation to non-asphyxiating acute bradycardia or tachycardia leading to unwarranted operative deliveries; (3) are based on classification of deviations from predefined baseline FHR, variability and decelerations to estimate the risk of intrapartum hypoxia, while the healthy fetus deploys changes in the same FHR features to adapt appropriately to hypoxia, making the distinction between the hypoxic and the non-hypoxic fetus challenging, resulting in unnecessary operative delivery and lack of recognition of the decompensating fetus; and (4) are silent on best practice for the management of intrapartum factors, which may interfere with fetal adaptation to intrapartum stressors such as fever, meconium, chorioamnionitis/fetal inflammation and the synergistic interaction between hypoxia and inflammation. We developed an algorithm for intrapartum FHR interpretation as part of service development, widely termed ‘physiology-based guidelines’, based on (1) establishing normal fetal behaviour in early labour, (2) fetal cardiovascular responses to intrapartum stressors and the development of progressive fetal compromise and noted lower than UK national averages for low Apgar score at 5 min, neonatal encephalopathy and emergency caesarean section (Em Cs) in a single tertiary unit in London. However, there are no clinical trials or prospective studies comparing the sensitivity and specificity of ‘physiology-based guidelines’ to established practice guidelines such as the International Federation of Gynaecology and Obstetrics 2015 guidelines for intrapartum FHR interpretation for neonatal and maternal outcomes, and the recent promotion of widespread use of the ‘physiology-based guidelines’ in a so-called ‘consensus expert opinion’ lacks evidence.Methods and analysis This is a prospective observational study comparing ‘physiology-based’ interpretation of intrapartum cardiotocography (CTG) to ‘guidelines-based’ interpretation in 2500 nulliparous women in term labour in the prediction of composite neonatal outcome, including 5-minute Apgar score <7, neonatal acidosis (pH <7.05 and base excess <−12 mmol/L), antenatal brain injury, admission to neonatal intensive care unit, neonatal encephalopathy, need for therapeutic hypothermia, neonatal sepsis, meconium aspiration syndrome, hypotonia, hypoglycaemia, feto-maternal haemorrhage, perinatal stroke and intrapartum or neonatal death <28 days. A secondary aim is to compare the incidence of Em Cs and instrumental vaginal delivery for fetal compromise between the two methods of interpretation. The study does not compare participants but the accuracy of two methods of interpretation of the same CTG from each woman in predicting a selection of perinatal outcomes, that is, 2500 comparisons in a total of 5000 CTG interpretations. There are no baseline differences.Based on experience and previous research, we estimated that about 3% of labours are complicated by acute FHR bradycardia and considered pathological, requiring intervention based on current guidance for intrapartum CTG interpretation. We expect that ‘physiology-based’ interpretation could reduce this proportion to 1%. Based on these assumptions, 2500 paired observations will allow more than 90% power to detect a McNemar’s OR of ≥3, including Bonferroni correction for multiple testing with components of the primary outcome and allowance for 20% sample loss.Ethics and dissemination The study was granted ethical approval by the Padua Regional Ethics Committee, code number CET-ACEV: 6259/AT/25, and accepted or reviewed by the local ethics committee of the participating centres. The results of the study will be disseminated at national and international conferences and published in peer-reviewed journals.Trial registration number ISRCTN59827903.

Related

  1. Ultraprocessed Foods, Neuroimaging, and Interpretation of Observational Evidence
    Russell J. de Souza, Anthea Christoforou
    JAMA Network OpenPeer-reviewedCC BY 4.0Epidemiology & public healthCrossref
  2. Antepartum electronic fetal monitoring interpretation: multicenter observational study.
    Paulino Vigil-De Gracia, Colisandra Robledo Paz, Cristobalina Campos Ávila +4
    BMC pregnancy and childbirthPeer-reviewedCC BY-NC-NDFull textObstetrics, gynaecology & paediatricsEurope PMCDOAJ
  3. Estimating dose-response relationships for vitamin D with coronary heart disease, stroke, and all-cause mortality: observational and Mendelian randomisation analyses
    Eleni Sofianopoulou, Stephen Kaptoge, Shoaib Afzal +83
    The Lancet. Diabetes & EndocrinologyPeer-reviewedCC BY 4.0Full text79 citedGeneral biologyEpidemiology & public healthHAL
  4. Artificial Intelligence Echocardiographic Interpretation in the Emergency Department: Agreement, Interpretation Yield and Reporting Scope
    Vijay Manivel, Michael Hession, Behzad Mirmiran +5
    Emergency medicine Australasia : EMAPeer-reviewedCC BY-NC-NDFull textGeneral medicineEurope PMC
  5. Hyperacute Guillain-Barré Syndrome: A Pathophysiological Interpretation
    José Berciano
    Internal MedicinePeer-reviewedCC BY-NC-NDFull textNeurologyJ-STAGE
BibTeX
@article{ugwumadu2026physiologybased,
  title = {{Physiology-based versus guideline-based interpretation of intrapartum cardiotocograph in nulliparous women in term labour at baseline and longitudinally in the prediction of early neonatal outcome: study protocol for a prospective observational study with randomisation of interpretation methods (the ‘PHYSGUIDE’ study)}},
  author = {Austin Ugwumadu and Virginia Whelehan and Agnese Suppiej and Gianpaolo Maso and Alessandra Meloni and Vincenzo Zanardo and Gianluca Straface},
  journal = {BMJ Open},
  year = {2026},
  month = nov,
  doi = {10.1136/bmjopen-2026-126867},
  url = {https://doi.org/10.1136/bmjopen-2026-126867},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Physiology-based versus guideline-based interpretation of intrapartum cardiotocograph in nulliparous women in term labour at baseline and longitudinally in the prediction of early neonatal outcome: study protocol for a prospective observational study with randomisation of interpretation methods (the ‘PHYSGUIDE’ study)
AU  - Austin Ugwumadu
AU  - Virginia Whelehan
AU  - Agnese Suppiej
AU  - Gianpaolo Maso
AU  - Alessandra Meloni
AU  - Vincenzo Zanardo
AU  - Gianluca Straface
PY  - 2026
DA  - 2026/11/25
JO  - BMJ Open
DO  - 10.1136/bmjopen-2026-126867
UR  - https://doi.org/10.1136/bmjopen-2026-126867
AB  - Introduction Current clinical guidelines for intrapartum fetal heart rate (FHR) monitoring (1) do not systematically exclude antenatal injuries or the baby’s ability to tolerate labour, thereby risking further injury; (2) do not acknowledge appropriate fetal adaptation to non-asphyxiating acute bradycardia or tachycardia leading to unwarranted operative deliveries; (3) are based on classification of deviations from predefined baseline FHR, variability and decelerations to estimate the risk of intrapartum hypoxia, while the healthy fetus deploys changes in the same FHR features to adapt appropriately to hypoxia, making the distinction between the hypoxic and the non-hypoxic fetus challenging, resulting in unnecessary operative delivery and lack of recognition of the decompensating fetus; and (4) are silent on best practice for the management of intrapartum factors, which may interfere with fetal adaptation to intrapartum stressors such as fever, meconium, chorioamnionitis/fetal inflammation and the synergistic interaction between hypoxia and inflammation. We developed an algorithm for intrapartum FHR interpretation as part of service development, widely termed ‘physiology-based guidelines’, based on (1) establishing normal fetal behaviour in early labour, (2) fetal cardiovascular responses to intrapartum stressors and the development of progressive fetal compromise and noted lower than UK national averages for low Apgar score at 5 min, neonatal encephalopathy and emergency caesarean section (Em Cs) in a single tertiary unit in London. However, there are no clinical trials or prospective studies comparing the sensitivity and specificity of ‘physiology-based guidelines’ to established practice guidelines such as the International Federation of Gynaecology and Obstetrics 2015 guidelines for intrapartum FHR interpretation for neonatal and maternal outcomes, and the recent promotion of widespread use of the ‘physiology-based guidelines’ in a so-called ‘consensus expert opinion’ lacks evidence.Methods and analysis This is a prospective observational study comparing ‘physiology-based’ interpretation of intrapartum cardiotocography (CTG) to ‘guidelines-based’ interpretation in 2500 nulliparous women in term labour in the prediction of composite neonatal outcome, including 5-minute Apgar score <7, neonatal acidosis (pH <7.05 and base excess <−12 mmol/L), antenatal brain injury, admission to neonatal intensive care unit, neonatal encephalopathy, need for therapeutic hypothermia, neonatal sepsis, meconium aspiration syndrome, hypotonia, hypoglycaemia, feto-maternal haemorrhage, perinatal stroke and intrapartum or neonatal death <28 days. A secondary aim is to compare the incidence of Em Cs and instrumental vaginal delivery for fetal compromise between the two methods of interpretation. The study does not compare participants but the accuracy of two methods of interpretation of the same CTG from each woman in predicting a selection of perinatal outcomes, that is, 2500 comparisons in a total of 5000 CTG interpretations. There are no baseline differences.Based on experience and previous research, we estimated that about 3% of labours are complicated by acute FHR bradycardia and considered pathological, requiring intervention based on current guidance for intrapartum CTG interpretation. We expect that ‘physiology-based’ interpretation could reduce this proportion to 1%. Based on these assumptions, 2500 paired observations will allow more than 90% power to detect a McNemar’s OR of ≥3, including Bonferroni correction for multiple testing with components of the primary outcome and allowance for 20% sample loss.Ethics and dissemination The study was granted ethical approval by the Padua Regional Ethics Committee, code number CET-ACEV: 6259/AT/25, and accepted or reviewed by the local ethics committee of the participating centres. The results of the study will be disseminated at national and international conferences and published in peer-reviewed journals.Trial registration number ISRCTN59827903.
SN  - 2044-6055
ER  -