Prospective evaluation of indocyanine green fluorescence for anastomotic site selection in laparoscopic colorectal cancer surgery
- 1Instituto do Câncer do Estado de São Paulo, Hospital das Clínicas, Faculdade de Medicina, Universidade de São Paulo (HCFMUSP), São Paulo, SP, Brazil
Abstract
Background: Indocyanine Green (ICG) fluorescence imaging has emerged as a valuable tool for intraoperative assessment of bowel perfusion in colorectal surgery, with the potential to reduce anastomotic leakage. However, standardized protocols for its use remain undefined. This study aimed to evaluate the feasibility and clinical impact of ICG fluorescence imaging in laparoscopic colorectal resections.
Methods: A prospective cohort of 60 patients undergoing laparoscopic sigmoidectomy or low anterior resection for colorectal cancer was analyzed. ICG was administered after high vascular ligation to guide anastomotic site selection. Perfusion was assessed using ICG fluorescence and the marginal arcade test. Primary outcomes were changes in anastomotic site and leakage rates; secondary outcomes included fluorescence time and its association with clinical variables.
Results: The mean time to fluorescence appearance was 24.5 seconds (range 8–45), with no significant differences according to sex (p = 0.20), age (p = 0.24), or neoadjuvant therapy (p = 0.38). ICG imaging led to modification of the planned anastomotic site in 6.7% of cases (n = 4), none of which developed leakage. In two cases, discordance between ICG fluorescence and marginal arcade assessment was observed. Overall, anastomotic leakage occurred in 6.7% (n = 4), exclusively in patients who had received neoadjuvant radiotherapy (p = 0.04). No association was found between leakage and anastomotic height, fluorescence time, or marginal arcade findings. No adverse reactions to ICG were reported.
Conclusion: ICG fluorescence imaging is a safe and feasible adjunct for intraoperative perfusion assessment that supports anastomotic site selection and may contribute to reducing anastomotic leakage. Further studies incorporating quantitative fluorescence metrics are warranted.
Related
- The Role of Intraoperative Indocyanine Green Fluorescence Angiography in Reducing Anastomotic Leak After Colorectal Resection: A Systematic Review of Randomised Controlled Trials
- Real-time Visualisation of the Extrahepatic Biliary System Using Indocyanine Green Fluorescence Cholangiography During Laparoscopic Cholecystectomy: A Prospective Cross-sectional Single-centre Study of 199 Cases
- Optimizing Indocyanine Green Fluorescence Cholangiography in Laparoscopic Cholecystectomy: A Systematic Review of Randomized Controlled Trials on Dose, Timing, Route, Efficacy, and Safety
- Advances in Indocyanine Green Near-Infrared Fluorescence for Extrahepatic Biliary Identification in Laparoscopic Cholecystectomy for Acute Cholecystitis: A Narrative Review.
- Indocyanine green fluorescence–guided laparoscopic anatomical hepatectomy for radical resection of hepatocellular carcinoma: a clinical study
BibTeX
@article{imperiale2026prospective,
title = {{Prospective evaluation of indocyanine green fluorescence for anastomotic site selection in laparoscopic colorectal cancer surgery}},
author = {Antonio Rocco Imperiale and Lucas Faraco Sobrado and Carlos Frederico Sparapan Marques and Caio Sérgio Rizkallah Nahas and Guilherme Cutait de Castro Cotti and Rossana Verônica Mendoza Lopez and Ulysses Ribeiro-Junior},
journal = {Clinics},
year = {2026},
month = oct,
doi = {10.1016/j.clinsp.2026.101226},
url = {https://doi.org/10.1016/j.clinsp.2026.101226},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Prospective evaluation of indocyanine green fluorescence for anastomotic site selection in laparoscopic colorectal cancer surgery
AU - Antonio Rocco Imperiale
AU - Lucas Faraco Sobrado
AU - Carlos Frederico Sparapan Marques
AU - Caio Sérgio Rizkallah Nahas
AU - Guilherme Cutait de Castro Cotti
AU - Rossana Verônica Mendoza Lopez
AU - Ulysses Ribeiro-Junior
PY - 2026
DA - 2026/10/27
JO - Clinics
DO - 10.1016/j.clinsp.2026.101226
UR - https://doi.org/10.1016/j.clinsp.2026.101226
AB - Background: Indocyanine Green (ICG) fluorescence imaging has emerged as a valuable tool for intraoperative assessment of bowel perfusion in colorectal surgery, with the potential to reduce anastomotic leakage. However, standardized protocols for its use remain undefined. This study aimed to evaluate the feasibility and clinical impact of ICG fluorescence imaging in laparoscopic colorectal resections. Methods: A prospective cohort of 60 patients undergoing laparoscopic sigmoidectomy or low anterior resection for colorectal cancer was analyzed. ICG was administered after high vascular ligation to guide anastomotic site selection. Perfusion was assessed using ICG fluorescence and the marginal arcade test. Primary outcomes were changes in anastomotic site and leakage rates; secondary outcomes included fluorescence time and its association with clinical variables. Results: The mean time to fluorescence appearance was 24.5 seconds (range 8–45), with no significant differences according to sex (p = 0.20), age (p = 0.24), or neoadjuvant therapy (p = 0.38). ICG imaging led to modification of the planned anastomotic site in 6.7% of cases (n = 4), none of which developed leakage. In two cases, discordance between ICG fluorescence and marginal arcade assessment was observed. Overall, anastomotic leakage occurred in 6.7% (n = 4), exclusively in patients who had received neoadjuvant radiotherapy (p = 0.04). No association was found between leakage and anastomotic height, fluorescence time, or marginal arcade findings. No adverse reactions to ICG were reported. Conclusion: ICG fluorescence imaging is a safe and feasible adjunct for intraoperative perfusion assessment that supports anastomotic site selection and may contribute to reducing anastomotic leakage. Further studies incorporating quantitative fluorescence metrics are warranted.
SN - 1807-5932
SN - 1980-5322
ER -