Skip to content
DraconiticResearch
Search Sources API
203,948 studies31 sourcesUpdated 33 min ago
Peer-reviewedCC BY 4.0Nutrients

Associations of Anthropometry and Handgrip Strength with Bioelectrical Impedance Parameters in Irritable Bowel Syndrome: A Cross-Sectional Study

  1. 1Department of Internal Medicine and Clinical Nutrition Centre, Third Faculty of Medicine, Thomayer University Hospital, Charles University, Vídeňská 800, 140 59 Prague 4, Czech Republic
  2. 2Nutrition and Dietetics Centre, Thomayer University Hospital, Vídeňská 800, 140 59 Prague 4, Czech Republic
  3. 3Department of Hygiene, Epidemiology and Preventive Medicine, Third Faculty of Medicine, Charles University, Ruská 87, 100 00 Prague 10, Czech Republic

Abstract

Background/Objectives: Simple anthropometry may complement nutritional assessment in irritable bowel syndrome (IBS). We examined the associations of arm anthropometry and handgrip strength (HGS) with bioelectrical impedance analysis (BIA) parameters. Methods: This cross-sectional baseline analysis included 55 adults with IBS-D or IBS-M for valid non-adiposity measurements; 54 contributed valid paired body-fat estimates, and 54 had valid dominant-hand HGS. Results: MUAMC correlated with BIA-derived skeletal muscle mass within men (Spearman’s ρ = 0.748) and women (ρ = 0.673). After adjustment for sex, age, height and body weight, the MUAMC association was attenuated (β = 0.0337 kg/mm, 95% CI 0.0059–0.0616; p = 0.0187). MUAMC was correlated with phase angle in the pooled sample (ρ = 0.806), but sex-related differences were exploratory. In a sensitivity model using the impedance index, the association was not significant after further adjustment for body weight (β = 0.0670, 95% CI −0.0087 to 0.1427; p = 0.0816). HGS correlated with BIA-derived skeletal muscle mass before adjustment (ρ = 0.769; n = 54), whereas an adjusted association was not established. BIA- and skinfold-derived body-fat estimates were correlated but showed proportional bias, limiting interchangeability. Conclusions: MUAMC is associated with BIA-derived muscle-related parameters, but mathematical coupling, body size and the absence of a criterion method limit causal and validation claims. Findings from this exploratory single-centre analysis require independent confirmation.

Related

  1. Missing Link between Glycemic Control and Bioelectrical Impedance Analysis
    Akinori Higaki
    Internal MedicinePeer-reviewedCC BY-NC-NDFull textPhysiologyJ-STAGE
  2. Bioelectrical impedance-derived body composition and systemic therapy outcomes in non-small cell lung cancer
    Xin Zheng, Rui Gao, Boao Jiang +11
    Translational Lung Cancer ResearchPeer-reviewedCC BY-NC-NDFull textOncologyEurope PMC
  3. Toward Clinically Feasible Assessment of Muscle Mass: Validation of a Seated Bioelectrical Impedance Device Against Dual-Energy X-Ray Absorptiometry (DXA) in Older Adults
    Elodie Piche, Emeline Michel, Olivier Guerin +2
    SensorsPeer-reviewedCC BY 4.0Full textPhysiologyHAL
  4. Association of electrical properties of bioelectrical impedance spectroscopy with sedentary time, physical activity and muscle function in older adults
    Murad H. Taani, Kimberly D. Bassindale, Yosuke Yamada +2
    BMC Public HealthPeer-reviewedCC BY 4.0Epidemiology & public healthCrossref
  5. Trimester-Specific Bioelectrical Impedance Reference Curves in Physiological Pregnancy: Mapping Maternal Body Composition and Hydration Trajectories
    Daniela Denis Di Martino, Elisa Sabattini, Lucrezia Viscioni +10
    NutrientsPeer-reviewedCC BY 4.0Full textPhysiologyCrossrefEurope PMC
BibTeX
@article{vejmelka2026associations,
  title = {{Associations of Anthropometry and Handgrip Strength with Bioelectrical Impedance Parameters in Irritable Bowel Syndrome: A Cross-Sectional Study}},
  author = {Jiří Vejmelka and Martina Kollerová and Ivana Pražanová and Khanh Ha Pham and Magdalena Trusinová and Pavel Kohout},
  journal = {Nutrients},
  year = {2026},
  month = nov,
  doi = {10.3390/nu18213711},
  url = {https://www.mdpi.com/2072-6643/18/21/3711},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Associations of Anthropometry and Handgrip Strength with Bioelectrical Impedance Parameters in Irritable Bowel Syndrome: A Cross-Sectional Study
AU  - Jiří Vejmelka
AU  - Martina Kollerová
AU  - Ivana Pražanová
AU  - Khanh Ha Pham
AU  - Magdalena Trusinová
AU  - Pavel Kohout
PY  - 2026
DA  - 2026/11/09
JO  - Nutrients
DO  - 10.3390/nu18213711
UR  - https://www.mdpi.com/2072-6643/18/21/3711
AB  - Background/Objectives: Simple anthropometry may complement nutritional assessment in irritable bowel syndrome (IBS). We examined the associations of arm anthropometry and handgrip strength (HGS) with bioelectrical impedance analysis (BIA) parameters. Methods: This cross-sectional baseline analysis included 55 adults with IBS-D or IBS-M for valid non-adiposity measurements; 54 contributed valid paired body-fat estimates, and 54 had valid dominant-hand HGS. Results: MUAMC correlated with BIA-derived skeletal muscle mass within men (Spearman’s ρ = 0.748) and women (ρ = 0.673). After adjustment for sex, age, height and body weight, the MUAMC association was attenuated (β = 0.0337 kg/mm, 95% CI 0.0059–0.0616; p = 0.0187). MUAMC was correlated with phase angle in the pooled sample (ρ = 0.806), but sex-related differences were exploratory. In a sensitivity model using the impedance index, the association was not significant after further adjustment for body weight (β = 0.0670, 95% CI −0.0087 to 0.1427; p = 0.0816). HGS correlated with BIA-derived skeletal muscle mass before adjustment (ρ = 0.769; n = 54), whereas an adjusted association was not established. BIA- and skinfold-derived body-fat estimates were correlated but showed proportional bias, limiting interchangeability. Conclusions: MUAMC is associated with BIA-derived muscle-related parameters, but mathematical coupling, body size and the absence of a criterion method limit causal and validation claims. Findings from this exploratory single-centre analysis require independent confirmation.
SN  - 2072-6643
ER  -