Skip to content
DraconiticResearch
Search Sources API
197,768 studies31 sourcesUpdated 23 min ago
PreprintCC BY-NC-NDbioRxiv

Phase-targeted Poisson closed-loop peripheral nerve stimulation modulates sensorimotor oscillations in human MEG

  1. 1Aston University

Abstract

Closed-loop brain stimulation offers a promising approach for modulating neural oscillations, but the mechanisms of phase-dependent neuromodulation remain poorly understood. We developed a real-time MEG-based closed-loop system delivering median nerve stimulation using a phase-modulated Poisson process. Sixteen healthy participants (11 female, 5 male) underwent open-loop characterization followed by closed-loop testing of eight phase-offset conditions (0 degrees-315 degrees), each paired with a statistically matched replay control. Closed-loop stimulation induced robust phase-dependent modulation (14.21 +/- 8.24%) versus replay (7.03 +/- 2.95%; p = 0.0003), with consistent phase specificity across participants (circular mean: 70.2 degrees, referenced to each individual's dominant frequency). At the group level, alpha oscillations (8-12 Hz) showed bidirectional modulation (mean boost: +21.0 +/- 19.9% at 0 degrees-135 degrees; mean suppression: -13.3 +/- 10.8% at 180 degrees-315 degrees), while beta oscillations (13-30 Hz) showed predominantly unidirectional suppression (-9.3 +/- 9.6%). Successful fixed-frequency targeting required alignment with each individual's natural peak. Misalignment led to different phase shifts producing power at different frequencies, a phenomenon we term phase-frequency coupling. Dynamic frequency tracking (8-30 Hz) automatically identified and targeted each individual's natural peak, achieving robust bidirectional modulation without prior knowledge of peak location. These findings demonstrate that real-time phase-locked peripheral nerve stimulation selectively modulates sensorimotor oscillations beyond statistically matched open-loop stimulation. The distinct phase-excitability relationships of alpha and beta oscillations, together with the importance of aligning stimulation with individual natural peaks, establish principled guidelines for personalized closed-loop neuromodulation.

Related

  1. A reduced multicompartment network model of CA1 theta–gamma oscillations under extracellular stimulation
    Maeva Andriantsoamberomanga, Nicolas P Rougier, Fabien Bertrand Paul Wagner +1
    HALPreprintCC BY 4.0Full text1 citedNeuroscienceHAL
  2. Closed-Loop Acoustic Stimulation of Slow Oscillations Using a Wireless EEG Headband: A Polysomnography-Validated Feasibility Study.
    Stefan L Jongejan, Anna C van der Heijden, Lucia M Talamini
    Sensors (Basel, Switzerland)Peer-reviewedCC BYFull textNeuroscienceEurope PMC
  3. Effect of stimulation parameters for transcranial temporal interference stimulation to enhance occipital alpha-oscillations in healthy participants
    J. Stalter, H. I. Stecher, A. Aleman +2
    bioRxivPreprintCC BY-NCFull textNeurosciencebioRxiv
  4. Short-term cortical stimulation combined with targeted rehabilitation and Chondroitinase ABC improves upper limb function following a cervical contusion injury
    e. sinopoulou, E. R. Burnside, K. Bartus +1
    bioRxivPreprintAll rights reservedFull textNeurosciencebioRxiv
  5. High frequency electrical stimulation paces fast spiking interneurons and modulates cellular information processing
    Pierre Fabris, Eric Lowet, Krishnakanth Kondabolu +4
    Communications BiologyPeer-reviewedCC BYFull textNeuroscienceDOAJ
BibTeX
@misc{baker2026phasetargeted,
  title = {{Phase-targeted Poisson closed-loop peripheral nerve stimulation modulates sensorimotor oscillations in human MEG}},
  author = {S. N. Baker and B. Zaaimi},
  howpublished = {bioRxiv},
  year = {2026},
  month = oct,
  doi = {10.64898/2026.10.01.755613},
  url = {https://www.biorxiv.org/content/10.64898/2026.10.01.755613v1},
  note = {CC BY-NC-ND},
}
RIS
TY  - UNPB
TI  - Phase-targeted Poisson closed-loop peripheral nerve stimulation modulates sensorimotor oscillations in human MEG
AU  - S. N. Baker
AU  - B. Zaaimi
PY  - 2026
DA  - 2026/10/01
PB  - bioRxiv
DO  - 10.64898/2026.10.01.755613
UR  - https://www.biorxiv.org/content/10.64898/2026.10.01.755613v1
AB  - Closed-loop brain stimulation offers a promising approach for modulating neural oscillations, but the mechanisms of phase-dependent neuromodulation remain poorly understood. We developed a real-time MEG-based closed-loop system delivering median nerve stimulation using a phase-modulated Poisson process. Sixteen healthy participants (11 female, 5 male) underwent open-loop characterization followed by closed-loop testing of eight phase-offset conditions (0 degrees-315 degrees), each paired with a statistically matched replay control. Closed-loop stimulation induced robust phase-dependent modulation (14.21 +/- 8.24%) versus replay (7.03 +/- 2.95%; p = 0.0003), with consistent phase specificity across participants (circular mean: 70.2 degrees, referenced to each individual's dominant frequency). At the group level, alpha oscillations (8-12 Hz) showed bidirectional modulation (mean boost: +21.0 +/- 19.9% at 0 degrees-135 degrees; mean suppression: -13.3 +/- 10.8% at 180 degrees-315 degrees), while beta oscillations (13-30 Hz) showed predominantly unidirectional suppression (-9.3 +/- 9.6%). Successful fixed-frequency targeting required alignment with each individual's natural peak. Misalignment led to different phase shifts producing power at different frequencies, a phenomenon we term phase-frequency coupling. Dynamic frequency tracking (8-30 Hz) automatically identified and targeted each individual's natural peak, achieving robust bidirectional modulation without prior knowledge of peak location. These findings demonstrate that real-time phase-locked peripheral nerve stimulation selectively modulates sensorimotor oscillations beyond statistically matched open-loop stimulation. The distinct phase-excitability relationships of alpha and beta oscillations, together with the importance of aligning stimulation with individual natural peaks, establish principled guidelines for personalized closed-loop neuromodulation.
ER  -