Skip to content
DraconiticResearch
Search Sources API
203,234 studies31 sourcesUpdated 59 min ago
PreprintCC BYmedRxiv

Development, validation and clinical implementation of cellular swab materials for quality assurance of pharmacogenomic point-of-care testing

  1. 1EMQN CIC, Exchange Quay, Salford, UK

Abstract

BackgroundPharmacogenomic point-of-care testing (PGx POCT) enables genotype-informed prescribing at the bedside, but implementation is limited by the lack of suitable reference materials for clinical verification and standardised external quality assessment (EQA).

MethodsFixed lymphoblastoid cell lines were formulated as swab-based materials at defined cellular inputs for MT-RNR1 POCT. Materials were evaluated using Genedrive(R) assays, quantitative PCR, acceptance quality limit batch release, workflow-perturbation testing and stability studies, then deployed for clinical verification and in an international EQA programme.

ResultsMaterials were homogeneous, workflow compatible and reproducible, with 100% correct genotype calls at the lowest intended manufacturing cell load. Clinical verification of 11 Genedrive(R) systems across five neonatal units demonstrated 99% concordance with expected genotype classifications (232/234 results). Seven EQA surveys yielded 253 participant results, with full-mark rates of 87.5-100%, and six test failures. Most failures occurred with low cell-input materials near the assay limit of detection. The materials supported genotype concordance, performance monitoring and identification of workflow and sample-related variability.

ConclusionsWorkflow-compatible cell-based reference materials combined with EQA provide a scalable framework for quality-assured PGx POCT beyond specialist laboratories. Clinical verification of Genedrive(R) systems within neonatal units using the cell-based swab materials, together with deployment of an International MT-RNR1 PGx POCT EQA programme, demonstrated their suitability for supporting both pre-implementation testing and ongoing quality assurance in decentralised healthcare settings. The framework may provide a model for the implementation, clinical verification and ongoing quality assessment of PGx POCT services. Further evaluation across platforms, analytes, settings and participant groups is required to establish broader applicability.

Related

  1. Validation and optimisation of wearable accelerometer data pre-processing for digital measure implementation and development
    Joss Langford, Jia Ying Chua, Ian Long +2
    PLOS OnePeer-reviewedCC BYFull textNeurosciencePhysiologyPLOSEurope PMC
  2. CT-based AI risk support for cystic renal masses: multicenter validation, reader study, and a randomized implementation study
    Chengwei Chen, Qinqin Kang, Yang Yang +11
    eClinicalMedicinePeer-reviewedCC BY-NC-ND 4.0General medicineCrossref
  3. First reported clinical implementation of pressurized intraperitoneal aerosol chemotherapy in Japan: Program development and 30-day outcomes in two patients
    Hiroshi Takeuchi, Yoshimasa Gohda, Joji Kitayama +5
    Global Health & MedicinePeer-reviewedLicence not statedFull textSurgery & anaesthesiaPMC
  4. Co-development, initial evaluation and implementation of a digital health intervention (SmartADHD) for young people (aged 16-30) with attention deficit hyperactivity disorder, including optimisation for sustainable delivery via health and social care settings: protocol for a mixed-methods study.
    Anna Price, Eleanor Bryant, James Wenger +3
    BMJ openPeer-reviewedCC BYFull textPsychiatry & mental healthEurope PMCCrossref
  5. Pediatric Inpatient Continuous Glucose Monitoring: Development and Implementation of a Hospital Policy for Accuracy-Validated Insulin Dosing
    Ming Yeh Lee, Hector I. Ortega, Christopher Chow-Parmer +13
    Diabetes technology & therapeuticsPeer-reviewedLicence not statedFull textEndocrinology & metabolismPMC
BibTeX
@misc{thomas2026development,
  title = {{Development, validation and clinical implementation of cellular swab materials for quality assurance of pharmacogenomic point-of-care testing}},
  author = {H. M. Thomas and J. H. McDermott and W. G. Newman and G. Miele and S. Ainsworth and S. J. Patton and R. Morra},
  howpublished = {medRxiv},
  year = {2026},
  month = oct,
  doi = {10.64898/2026.10.13.26365321},
  url = {https://www.medrxiv.org/content/10.64898/2026.10.13.26365321v1},
  note = {CC BY},
}
RIS
TY  - UNPB
TI  - Development, validation and clinical implementation of cellular swab materials for quality assurance of pharmacogenomic point-of-care testing
AU  - H. M. Thomas
AU  - J. H. McDermott
AU  - W. G. Newman
AU  - G. Miele
AU  - S. Ainsworth
AU  - S. J. Patton
AU  - R. Morra
PY  - 2026
DA  - 2026/10/13
PB  - medRxiv
DO  - 10.64898/2026.10.13.26365321
UR  - https://www.medrxiv.org/content/10.64898/2026.10.13.26365321v1
AB  - BackgroundPharmacogenomic point-of-care testing (PGx POCT) enables genotype-informed prescribing at the bedside, but implementation is limited by the lack of suitable reference materials for clinical verification and standardised external quality assessment (EQA).  MethodsFixed lymphoblastoid cell lines were formulated as swab-based materials at defined cellular inputs for MT-RNR1 POCT. Materials were evaluated using Genedrive(R) assays, quantitative PCR, acceptance quality limit batch release, workflow-perturbation testing and stability studies, then deployed for clinical verification and in an international EQA programme.  ResultsMaterials were homogeneous, workflow compatible and reproducible, with 100% correct genotype calls at the lowest intended manufacturing cell load. Clinical verification of 11 Genedrive(R) systems across five neonatal units demonstrated 99% concordance with expected genotype classifications (232/234 results). Seven EQA surveys yielded 253 participant results, with full-mark rates of 87.5-100%, and six test failures. Most failures occurred with low cell-input materials near the assay limit of detection. The materials supported genotype concordance, performance monitoring and identification of workflow and sample-related variability.  ConclusionsWorkflow-compatible cell-based reference materials combined with EQA provide a scalable framework for quality-assured PGx POCT beyond specialist laboratories. Clinical verification of Genedrive(R) systems within neonatal units using the cell-based swab materials, together with deployment of an International MT-RNR1 PGx POCT EQA programme, demonstrated their suitability for supporting both pre-implementation testing and ongoing quality assurance in decentralised healthcare settings. The framework may provide a model for the implementation, clinical verification and ongoing quality assessment of PGx POCT services. Further evaluation across platforms, analytes, settings and participant groups is required to establish broader applicability.
ER  -