Dosimetric Characterization and Workflow Optimization of the FLASH-SARRP for Reliable Preclinical Radiobiological Studies
- 1HUG
Abstract
Objective: The reliable use of preclinical small-animal irradiators requires dosimetric characterization and quality assurance (QA) protocols. This study aimed to characterize the FLASH-SARRP, a dual-tube small-animal X-ray irradiator capable of ultra-high dose-rate (UHDR) delivery, as well as to establish and validate a practical QA workflow that improves dose reproducibility for preclinical FLASH experiments. Approach: A combined dosimetric approach using Gafchromic films for spatial dose assessment and a plastic scintillating fiber for real-time temporal monitoring, was used to evaluate beam characteristics. Custom 3D-printed spacers were designed to ensure reproducible experimental configurations. The temporal pulse structure of the two X-ray tubes and their synchronization during simultaneous irradiation were investigated using scintillating fiber measurements. Based on the findings of the two dosimeters, a QA workflow was implemented and validated, which uses a cross-calibration between the Gafchromic film and the scintillating fiber in the experimental setup, followed by pre-irradiation verification with the fiber to compensate for day-to-day output variations. Main results: Simultaneous irradiation of both X-ray tubes achieved dose-rates of approximately 80 Gy/s inside a homogeneous irradiation field suitable for small-animal studies. Temporal measurements revealed an average delay of 10 ms in between the two X-ray tubes, resulting in temporal dose-rate heterogeneity throughout the delivery of the dose. Additionally, a substantial inter-session variability of approximately 11% was found, whereas the intra-session variability was relatively low around ~4%. Implementation of the proposed QA workflow reduced the inter-session variability to around 5%, approaching the intrinsic intra-session variability of the machine. Significance: This work highlights the importance of temporal dosimetry for preclinical FLASH studies, as a measurable desynchronization between the two X-ray tubes was identified, generating temporal dose-rate heterogeneity that would not be detected by integrated dose measurements alone. The proposed QA framework improves reproducibility and provides a practical approach for reliable preclinical investigations.
Related
- Hypofractionated Total Marrow and Lymphoid Irradiation for Relapsed/Refractory Leukemia Using Helical Tomotherapy: Workflow and Dosimetric Analysis
- Pharmacokinetic and dosimetric evaluation of [177Lu]Lu-FAPI for stromal-targeted radionuclide therapy in triple-negative breast cancer: a preclinical biodistribution and dosimetry study
- Pilot Cross-Platform Bench Characterization of Injectable Biostimulator Products Using a Predefined Descriptive Workflow
- Optimization of a Subcutaneous Epithelioid Hemangioendothelioma Xenograft Model for Evaluation of Preclinical Therapeutics
- Characterization of the Preclinical in Vitro and in Vivo Pharmacokinetic Properties of the Cyclic Oligomeric Depsipeptide Ryanodine Receptor 2 Inhibitor ent-Verticilide
BibTeX
@misc{knol2026dosimetric,
title = {{Dosimetric Characterization and Workflow Optimization of the FLASH-SARRP for Reliable Preclinical Radiobiological Studies}},
author = {M. Knol and P. Goncalves Jorge and L. V. Kunz and P. Korysko and B. Petit and A. Durham and V. Marie-catherine and P. Tsoutsou and N. Koutsouvelis and J. Lascaud},
howpublished = {bioRxiv},
year = {2026},
month = jul,
doi = {10.64898/2026.07.06.736680},
url = {https://www.biorxiv.org/content/10.64898/2026.07.06.736680v2},
note = {CC BY},
}
RIS
TY - UNPB
TI - Dosimetric Characterization and Workflow Optimization of the FLASH-SARRP for Reliable Preclinical Radiobiological Studies
AU - M. Knol
AU - P. Goncalves Jorge
AU - L. V. Kunz
AU - P. Korysko
AU - B. Petit
AU - A. Durham
AU - V. Marie-catherine
AU - P. Tsoutsou
AU - N. Koutsouvelis
AU - J. Lascaud
PY - 2026
DA - 2026/07/06
PB - bioRxiv
DO - 10.64898/2026.07.06.736680
UR - https://www.biorxiv.org/content/10.64898/2026.07.06.736680v2
AB - Objective: The reliable use of preclinical small-animal irradiators requires dosimetric characterization and quality assurance (QA) protocols. This study aimed to characterize the FLASH-SARRP, a dual-tube small-animal X-ray irradiator capable of ultra-high dose-rate (UHDR) delivery, as well as to establish and validate a practical QA workflow that improves dose reproducibility for preclinical FLASH experiments. Approach: A combined dosimetric approach using Gafchromic films for spatial dose assessment and a plastic scintillating fiber for real-time temporal monitoring, was used to evaluate beam characteristics. Custom 3D-printed spacers were designed to ensure reproducible experimental configurations. The temporal pulse structure of the two X-ray tubes and their synchronization during simultaneous irradiation were investigated using scintillating fiber measurements. Based on the findings of the two dosimeters, a QA workflow was implemented and validated, which uses a cross-calibration between the Gafchromic film and the scintillating fiber in the experimental setup, followed by pre-irradiation verification with the fiber to compensate for day-to-day output variations. Main results: Simultaneous irradiation of both X-ray tubes achieved dose-rates of approximately 80 Gy/s inside a homogeneous irradiation field suitable for small-animal studies. Temporal measurements revealed an average delay of 10 ms in between the two X-ray tubes, resulting in temporal dose-rate heterogeneity throughout the delivery of the dose. Additionally, a substantial inter-session variability of approximately 11% was found, whereas the intra-session variability was relatively low around ~4%. Implementation of the proposed QA workflow reduced the inter-session variability to around 5%, approaching the intrinsic intra-session variability of the machine. Significance: This work highlights the importance of temporal dosimetry for preclinical FLASH studies, as a measurable desynchronization between the two X-ray tubes was identified, generating temporal dose-rate heterogeneity that would not be detected by integrated dose measurements alone. The proposed QA framework improves reproducibility and provides a practical approach for reliable preclinical investigations.
ER -