Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 19 min ago
Peer-reviewedCC BY 4.0Hla

Predicting the 1:10 Diluted MFI of Luminex Single Antigen Beads: A Tool for Assessing Antibody Strength and Desensitisation Eligibility

11 affiliations
  1. 1EPFL Lausanne Switzerland
  2. 2Unité Mixte de Recherche (UMR) 1342, Institut de Recherche Saint‐Louis (IRSL) Université Paris‐Cité, Hôpital Saint‐Louis Paris France
  3. 3MICS Laboratory CentraleSupélec, Paris‐Saclay University Gif‐sur‐Yvette France
  4. 4Gustave Roussy, Inserm, CentraleSupélec, Cancer Data Science Unit, IHU PRISM National PRecISion Medicine Center in Oncology Université Paris‐Saclay Gif‐sur‐Yvette France
  5. 5Laboratoire d'Histocompatibilité et d'Immunogénétique Établissement Français du Sang (EFS) Grand Est Strasbourg France
  6. 6Laboratory of Histocompatibility and Immunogenetic Toulouse Purpan University Hospital (CHU de Toulouse) Toulouse France
  7. 7Institute of Metabolic and Cardiovascular Diseases (I2MC), Team ‘Cell Signaling in Response to Arterial Stress: Impact on Cardiovascular Diseases’, INSERM U1297 University of Toulouse 3 Toulouse France
  8. 8Laborastoire d'Histocompatibilité et d'Immunogénétique Établissement Français du Sang (EFS) Centre‐Pays de la Loire Tours France
  9. 9Laboratoire d'Histocompatibilité et d'Immunogénétique Établissement Français du Sang (EFS) Nouvelle‐Aquitaine Poitiers France
  10. 10Laboratoire d'Immunologie, CHU de Reims Pôle de Biologie Médicale et Pathologie Reims France
  11. 11Laboratoire d'Immunologie et Histocompatibilité Hôpital Saint‐Louis, AP‐HP Paris France

Abstract

The Luminex Single Antigen (LSA) bead assay is the reference method for anti‐HLA antibody detection in transplantation. Mean Fluorescence Intensity (MFI) is a semi‐quantitative measure of antibody strength but saturates at high values. Serum dilution, recommended to refine quantification, has a non‐linear and poorly characterised relationship to neat MFI. We retrospectively analysed paired neat and 1:10 diluted MFI from two cohorts: a monocentric development cohort (Saint‐Louis Hospital, AP‐HP) used for model fitting, and a multicentric external validation cohort from five histocompatibility laboratories used to assess transportability. The dilution function was modelled by locally weighted scatterplot smoothing (LOWESS) regression, with hyperparameters selected by the Bayesian Information Criterion (BIC); 95% prediction intervals were estimated locally from candidate residual distributions (Gaussian and SkewNormal). The empirical low‐MFI slope was compared to the theoretical 0.10 expected from a 1:10 dilution. The development dataset comprised 237,547 paired measurements from 644 patients and 1,965 sera. The retained model was a degree‐2 locally quadratic estimator with Gaussian kernel and bandwidth 1500; residuals were best fitted by a SkewNormal distribution. For a neat MFI of 8,000, the predicted diluted MFI was 2,130 (95% PI: 650–4,640). The empirical low‐MFI slope was 0.219, substantially exceeding the theoretical 0.10. External validation on 18,642 measurements from 104 sera across four laboratories yielded a 95% prediction interval coverage of 93.9%. A non‐parametric model with locally adapted prediction intervals is provided to predict the 1:10 diluted MFI without performing serum dilution, supporting clinical decision‐making. Each predicted value comes with its prediction interval, whose width increases with neat MFI and is greatest in the saturating range.

Related

  1. Sensory Regulation, Theraplay®, Eye Movement Desensitisation and Reprocessing, and Dyadic Developmental Psychotherapy Integration (STEDi) for Adoptive Children who have Experienced Developmental Trauma and Attachment Disruptions: A Mixed-Methods Preliminary Evaluation
    Jack Purrington, Caitlin Manning, Georgia York
    Journal of Child & Adolescent TraumaPeer-reviewedLicence not statedFull textPsychiatry & mental healthPMC
  2. Prospective evaluation assessing the influence of outcome definition, cohort inclusion and DORIS remission in predicting adverse pregnancy outcomes in women with systemic lupus erythematosus.
    Camila Hernández-Blanco, Philip M Carlucci, Erin Carter +10
    Lupus science & medicinePeer-reviewedCC BY-NCFull textGeneral medicineEurope PMC
  3. Assessing the utility of two sarcopenia screening tools in predicting mortality risk among survivors of critical illness: a single-center study
    Long Chen, Juan Xu, Raoman Feng +1
    Scientific ReportsPeer-reviewedCC BYFull textPhysiologyDOAJ
  4. Shear-Wave Elastography for Predicting the Occurrence and Assessing the Severity of Capsular Contracture After Implant-Based Breast Augmentation and Reconstruction: A Review of the Evidence
    Mihai Iliescu-Glaja, Fabiana Simion, Andrei Motoc +3
    Journal of Clinical MedicinePeer-reviewedCC BY 4.0Surgery & anaesthesiaCrossref
  5. Handgrip strength for predicting incident ADL disability in older adults with arthritis: a multi-cohort external validation study.
    Chen Yu, Zebin Wang, Gang Gao
    BMC geriatricsPeer-reviewedCC BY-NC-NDFull textPhysiologyEurope PMCPMC
BibTeX
@article{janin2026predicting,
  title = {{Predicting the 1:10 Diluted MFI of Luminex Single Antigen Beads: A Tool for Assessing Antibody Strength and Desensitisation Eligibility}},
  author = {Alexis Janin and Cédric Usureau and Marie‐Joëlle Apithy and Nicolas Congy‐Jolivet and Barbara Proust and Camille Humeau and Isabelle Jollet and Grégory Gatouillat and Jean‐Luc Taupin and Véronique Letort},
  journal = {Hla},
  year = {2026},
  month = nov,
  doi = {10.1111/tan.71098},
  url = {https://doi.org/10.1111/tan.71098},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Predicting the 1:10 Diluted MFI of Luminex Single Antigen Beads: A Tool for Assessing Antibody Strength and Desensitisation Eligibility
AU  - Alexis Janin
AU  - Cédric Usureau
AU  - Marie‐Joëlle Apithy
AU  - Nicolas Congy‐Jolivet
AU  - Barbara Proust
AU  - Camille Humeau
AU  - Isabelle Jollet
AU  - Grégory Gatouillat
AU  - Jean‐Luc Taupin
AU  - Véronique Letort
PY  - 2026
DA  - 2026/11/23
JO  - Hla
DO  - 10.1111/tan.71098
UR  - https://doi.org/10.1111/tan.71098
AB  - The Luminex Single Antigen (LSA) bead assay is the reference method for anti‐HLA antibody detection in transplantation. Mean Fluorescence Intensity (MFI) is a semi‐quantitative measure of antibody strength but saturates at high values. Serum dilution, recommended to refine quantification, has a non‐linear and poorly characterised relationship to neat MFI. We retrospectively analysed paired neat and 1:10 diluted MFI from two cohorts: a monocentric development cohort (Saint‐Louis Hospital, AP‐HP) used for model fitting, and a multicentric external validation cohort from five histocompatibility laboratories used to assess transportability. The dilution function was modelled by locally weighted scatterplot smoothing (LOWESS) regression, with hyperparameters selected by the Bayesian Information Criterion (BIC); 95% prediction intervals were estimated locally from candidate residual distributions (Gaussian and SkewNormal). The empirical low‐MFI slope was compared to the theoretical 0.10 expected from a 1:10 dilution. The development dataset comprised 237,547 paired measurements from 644 patients and 1,965 sera. The retained model was a degree‐2 locally quadratic estimator with Gaussian kernel and bandwidth 1500; residuals were best fitted by a SkewNormal distribution. For a neat MFI of 8,000, the predicted diluted MFI was 2,130 (95% PI: 650–4,640). The empirical low‐MFI slope was 0.219, substantially exceeding the theoretical 0.10. External validation on 18,642 measurements from 104 sera across four laboratories yielded a 95% prediction interval coverage of 93.9%. A non‐parametric model with locally adapted prediction intervals is provided to predict the 1:10 diluted MFI without performing serum dilution, supporting clinical decision‐making. Each predicted value comes with its prediction interval, whose width increases with neat MFI and is greatest in the saturating range.
SN  - 2059-2302
SN  - 2059-2310
ER  -