Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 38 min ago
Peer-reviewedCC BY 4.0Journal of Clinical Medicine

Mammography-Based Artificial Intelligence for Breast Arterial Calcification Detection, Quantification, and Cardiovascular Risk Assessment: A Systematic Review

  1. 1Division of Breast Imaging, Department of Radiology, The University of North Carolina at Chapel Hill, Chapel Hill, NC 27599, USA
  2. 2Carolina Mammography Registry, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599, USA

Abstract

Background/Objectives: Artificial intelligence (AI) may automate breast arterial calcification (BAC) assessment and extract cardiovascular information from mammograms. In this study, we review technical BAC assessment, computed tomography (CT)-derived coronary artery calcification (CAC) surrogate assessment, and cardiovascular associations and prediction. Methods: MEDLINE and Embase were searched through 29 August 2026, supplemented by citation searching. Reports were synthesized narratively by target task, reference standard, and predictor type. QUADAS-2 and PROBAST informed risk-of-bias assessment. Results: Database screening yielded 17 eligible reports, and citation searching added three, resulting in 20 reports from 19 studies. These included 12 technical BAC reports, two CAC-surrogate reports, and six cardiovascular reports comprising five BAC-specific studies and one whole-mammogram study. BAC-detection areas under the receiver operating characteristic curve (AUCs) reached 0.95–0.96; segmentation Jaccard coefficients were approximately 0.58–0.61, and one small internal validation reported a Dice of 0.89. Mammography-only CAC AUCs ranged from 0.761 to 0.850 across thresholds; an AI-derived BAC score yielded AUC 0.64 for marked CAC. In an external health system cohort, severe versus absent BAC was associated with major adverse cardiovascular events after adjustment for Predicting Risk of cardiovascular disease EVENTs (PREVENT) (hazard ratio 2.80; 95% confidence interval 2.36–3.32). Separately, adding categorical BAC to PREVENT increased the external cohort C-index from 0.62 to 0.64. Conclusions: AI enables automated BAC assessment, and BAC-derived measures show prognostic associations with limited evidence of incremental predictive performance. Whole-mammogram models provide complementary evidence that cannot establish BAC-specific prognostic value. These tasks require separate interpretation. Standardized measurement, external validation, calibration, and prospective evidence of clinical benefit remain necessary.

Related

  1. Artificial intelligence for breast arterial calcification detection on mammography: A systematic review of diagnostic accuracy
    A Price Campbell, Leticia Petfield, Eric C Nemec Ii +1
    PLOS Digital HealthPeer-reviewedCC BYFull textCardiovascular medicineMedical imaging & radiologyPLOSEurope PMC
  2. Deep-Learning-Based Assessment of Breast Arterial Calcification on Mammography: Technical Validation, Cardiovascular Prognostic Value, and Clinical Translation—A Narrative Review
    Alexandru Carauleanu, Amelian M. Bobu, Elena Porumb-Andrese +8
    Medical sciences (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
  3. Kaiser Permanente National Cross-Vendor Validation of Mammography Artificial Intelligence Computer-Aided Diagnosis Algorithms in a US-Representative Population
    V. Arasu, T. Gadgil, M. Westley +7
    medRxivPreprintAll rights reservedFull textMedical imaging & radiologymedRxiv
  4. NOTIFY-DISCUSS: Patient and clinician perspectives on opportunistic screening for coronary artery calcification using artificial intelligence
    Emily Keamy-Minor, Ramzi Dudum, Cassandra L. Bragdon +7
    American Heart Journal PlusPeer-reviewedCC BY-NC-NDFull textMedical imaging & radiologyDOAJEurope PMCPMC
  5. Real-world performance of a Food and Drug Administration–approved artificial intelligence tool for mammography in patients with prior breast surgery or indwelling biopsy clips
    Emily B Ambinder, Colin Paulbeck, Shuchi Zinzuwadia +4
    Radiology AdvancesPeer-reviewedCC BY 4.0Full textMedical imaging & radiologyPMC
BibTeX
@article{ferre2026mammographybased,
  title = {{Mammography-Based Artificial Intelligence for Breast Arterial Calcification Detection, Quantification, and Cardiovascular Risk Assessment: A Systematic Review}},
  author = {Romuald Ferré and Thad Benefield and Cherie M. Kuzmiak},
  journal = {Journal of Clinical Medicine},
  year = {2026},
  month = nov,
  doi = {10.3390/jcm15229003},
  url = {https://www.mdpi.com/2077-0383/15/22/9003},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Mammography-Based Artificial Intelligence for Breast Arterial Calcification Detection, Quantification, and Cardiovascular Risk Assessment: A Systematic Review
AU  - Romuald Ferré
AU  - Thad Benefield
AU  - Cherie M. Kuzmiak
PY  - 2026
DA  - 2026/11/01
JO  - Journal of Clinical Medicine
DO  - 10.3390/jcm15229003
UR  - https://www.mdpi.com/2077-0383/15/22/9003
AB  - Background/Objectives: Artificial intelligence (AI) may automate breast arterial calcification (BAC) assessment and extract cardiovascular information from mammograms. In this study, we review technical BAC assessment, computed tomography (CT)-derived coronary artery calcification (CAC) surrogate assessment, and cardiovascular associations and prediction. Methods: MEDLINE and Embase were searched through 29 August 2026, supplemented by citation searching. Reports were synthesized narratively by target task, reference standard, and predictor type. QUADAS-2 and PROBAST informed risk-of-bias assessment. Results: Database screening yielded 17 eligible reports, and citation searching added three, resulting in 20 reports from 19 studies. These included 12 technical BAC reports, two CAC-surrogate reports, and six cardiovascular reports comprising five BAC-specific studies and one whole-mammogram study. BAC-detection areas under the receiver operating characteristic curve (AUCs) reached 0.95–0.96; segmentation Jaccard coefficients were approximately 0.58–0.61, and one small internal validation reported a Dice of 0.89. Mammography-only CAC AUCs ranged from 0.761 to 0.850 across thresholds; an AI-derived BAC score yielded AUC 0.64 for marked CAC. In an external health system cohort, severe versus absent BAC was associated with major adverse cardiovascular events after adjustment for Predicting Risk of cardiovascular disease EVENTs (PREVENT) (hazard ratio 2.80; 95% confidence interval 2.36–3.32). Separately, adding categorical BAC to PREVENT increased the external cohort C-index from 0.62 to 0.64. Conclusions: AI enables automated BAC assessment, and BAC-derived measures show prognostic associations with limited evidence of incremental predictive performance. Whole-mammogram models provide complementary evidence that cannot establish BAC-specific prognostic value. These tasks require separate interpretation. Standardized measurement, external validation, calibration, and prospective evidence of clinical benefit remain necessary.
SN  - 2077-0383
ER  -