Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 31 min ago
Peer-reviewedCC BY 4.0Radiology Advances

Real-world performance of a Food and Drug Administration–approved artificial intelligence tool for mammography in patients with prior breast surgery or indwelling biopsy clips

Abstract

Background: Artificial intelligence (AI) tools are increasingly used in clinical screening mammography, but their performance in patients with prior breast surgery or indwelling biopsy clips, who represent a substantial proportion of screening populations, has not been well characterized.

Purpose: To evaluate the real-world performance of an Food and Drug Administration–approved AI mammography tool in patients with prior breast surgery or biopsy clips.

Methods and Materials: We retrospectively reviewed all screening mammograms performed at our institution between August 1, 2024, and February 28, 2025, after implementation of a commercially available AI tool (Transpara 1.7.4-A), merging clinical outcomes with the AI risk score (low, intermediate, or elevated). Patients were stratified by procedural history into 3 groups: prior breast surgery, biopsy clip, and reference (ie, neither intervention). Sensitivity, positive predictive value (PPV), and false positive rate (FPR) at the elevated and intermediate + elevated thresholds were compared using Fisher exact tests presented as percentage (95% confidence interval [CI]).

Results: A total of 24 427 screening mammograms were included (mean age 61 ± 13 years): 19 287 in the reference group, 2647 in the surgery group, and 2493 in the biopsy clip group. AI sensitivity at the intermediate + elevated threshold was preserved (reference 92.1% [95% CI, 86.9%-95.3%], surgery 90.5% [95% CI, 71.1%-97.3%], biopsy clip 90.0% [95% CI, 69.9%-97.2%]; both P > .6). The AI-PPV of an elevated exam was correspondingly reduced in altered-breast patients (reference 13.6% [95% CI, 11.1%-16.6%], surgery 5.5% [95% CI, 2.9%-10.0%], biopsy clip 4.9% [95% CI, 2.5%-9.4%]; both P < .005 vs reference). The AI-FPR was higher in both subgroups at the intermediate + elevated threshold (reference 35.6% [95% CI, 34.9%-36.3%] vs surgery 47.9% [95% CI, 46.0%-49.9%] and biopsy clip 47.9% [95% CI, 45.9%-49.8%]; both P < .001) and more than doubled at the elevated threshold (reference 2.7% [95% CI, 2.5%-2.9%] vs surgery 5.9% [95% CI, 5.1%-6.9%] and biopsy clip 6.2% [95% CI, 5.3%-7.2%]; both P < .001).

Conclusion: AI examination–level sensitivity for breast cancer was preserved in patients with prior breast surgery or indwelling biopsy clips. However, an elevated AI risk score was less likely to reflect a cancer in these patients than in the reference group, with a lower AI-PPV and higher AI-FPR.

Related

  1. Kaiser Permanente National Cross-Vendor Validation of Mammography Artificial Intelligence Computer-Aided Diagnosis Algorithms in a US-Representative Population
    V. Arasu, T. Gadgil, M. Westley +7
    medRxivPreprintAll rights reservedFull textMedical imaging & radiologymedRxiv
  2. Mammography-Based Artificial Intelligence for Breast Arterial Calcification Detection, Quantification, and Cardiovascular Risk Assessment: A Systematic Review
    Romuald Ferré, Thad Benefield, Cherie M. Kuzmiak
    Journal of Clinical MedicinePeer-reviewedCC BY 4.0Full textGeneral medicineCrossrefEurope PMC
  3. Artificial intelligence for breast arterial calcification detection on mammography: A systematic review of diagnostic accuracy
    A Price Campbell, Leticia Petfield, Eric C Nemec Ii +1
    PLOS Digital HealthPeer-reviewedCC BYFull textCardiovascular medicineMedical imaging & radiologyPLOSEurope PMC
  4. CT-Referenced Diagnostic Performance and Complementary Error Patterns of Artificial Intelligence Versus a Single Emergency Physician in Chest Radiograph Interpretation: A Retrospective Paired Diagnostic Accuracy Study
    Ömer Damar, Mahmut Yaman
    TomographyPeer-reviewedCC BYFull textMedical imaging & radiologyEurope PMC
  5. Evaluating the impact of social determinants of health on model performance and fairness in artificial intelligence for glaucoma progression prediction
    Sean YT Lin, Rohith Ravindranath, Joshua D. Stein +2
    Journal of the American Medical Informatics Association : JAMIAPeer-reviewedPublisher termsFull textGeneral medicinePMC
BibTeX
@article{ambinder2026realworld,
  title = {{Real-world performance of a Food and Drug Administration–approved artificial intelligence tool for mammography in patients with prior breast surgery or indwelling biopsy clips}},
  author = {Emily B Ambinder and Colin Paulbeck and Shuchi Zinzuwadia and Lisa Mullen and Kelly S Myers and Eniola Oluyemi and Babita Panigrahi},
  journal = {Radiology Advances},
  year = {2026},
  month = oct,
  doi = {10.1093/radadv/umag042},
  url = {https://doi.org/10.1093/radadv/umag042},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Real-world performance of a Food and Drug Administration–approved artificial intelligence tool for mammography in patients with prior breast surgery or indwelling biopsy clips
AU  - Emily B Ambinder
AU  - Colin Paulbeck
AU  - Shuchi Zinzuwadia
AU  - Lisa Mullen
AU  - Kelly S Myers
AU  - Eniola Oluyemi
AU  - Babita Panigrahi
PY  - 2026
DA  - 2026/10/10
JO  - Radiology Advances
DO  - 10.1093/radadv/umag042
UR  - https://doi.org/10.1093/radadv/umag042
AB  - Background: Artificial intelligence (AI) tools are increasingly used in clinical screening mammography, but their performance in patients with prior breast surgery or indwelling biopsy clips, who represent a substantial proportion of screening populations, has not been well characterized.  Purpose: To evaluate the real-world performance of an Food and Drug Administration–approved AI mammography tool in patients with prior breast surgery or biopsy clips.  Methods and Materials: We retrospectively reviewed all screening mammograms performed at our institution between August 1, 2024, and February 28, 2025, after implementation of a commercially available AI tool (Transpara 1.7.4-A), merging clinical outcomes with the AI risk score (low, intermediate, or elevated). Patients were stratified by procedural history into 3 groups: prior breast surgery, biopsy clip, and reference (ie, neither intervention). Sensitivity, positive predictive value (PPV), and false positive rate (FPR) at the elevated and intermediate + elevated thresholds were compared using Fisher exact tests presented as percentage (95% confidence interval [CI]).  Results: A total of 24 427 screening mammograms were included (mean age 61 ± 13 years): 19 287 in the reference group, 2647 in the surgery group, and 2493 in the biopsy clip group. AI sensitivity at the intermediate + elevated threshold was preserved (reference 92.1% [95% CI, 86.9%-95.3%], surgery 90.5% [95% CI, 71.1%-97.3%], biopsy clip 90.0% [95% CI, 69.9%-97.2%]; both P > .6). The AI-PPV of an elevated exam was correspondingly reduced in altered-breast patients (reference 13.6% [95% CI, 11.1%-16.6%], surgery 5.5% [95% CI, 2.9%-10.0%], biopsy clip 4.9% [95% CI, 2.5%-9.4%]; both P < .005 vs reference). The AI-FPR was higher in both subgroups at the intermediate + elevated threshold (reference 35.6% [95% CI, 34.9%-36.3%] vs surgery 47.9% [95% CI, 46.0%-49.9%] and biopsy clip 47.9% [95% CI, 45.9%-49.8%]; both P < .001) and more than doubled at the elevated threshold (reference 2.7% [95% CI, 2.5%-2.9%] vs surgery 5.9% [95% CI, 5.1%-6.9%] and biopsy clip 6.2% [95% CI, 5.3%-7.2%]; both P < .001).  Conclusion: AI examination–level sensitivity for breast cancer was preserved in patients with prior breast surgery or indwelling biopsy clips. However, an elevated AI risk score was less likely to reflect a cancer in these patients than in the reference group, with a lower AI-PPV and higher AI-FPR.
SN  - 2976-9337
ER  -