Abstract
Background: Parkinson's disease (PD) is a progressive neurodegenerative disorder characterized by motor dysfunction and is commonly treated with subthalamic nucleus deep brain stimulation (STN-DBS) in patients with advanced motor complications. Conventional continuous deep brain stimulation (cDBS) delivers uninterrupted stimulation, whereas adaptive deep brain stimulation (aDBS) adjusts stimulation according to physiological biomarkers or other signals. Although aDBS may improve motor control while reducing stimulation delivery, its comparative effectiveness and safety remain uncertain.
Methods: This systematic review and meta-analysis was conducted in accordance with PRISMA guidelines. PubMed, Embase, Scopus, and Cochrane CENTRAL were searched for eligible studies published between January 2013 and May 2026. Studies involving adults with idiopathic PD that compared aDBS with cDBS were included. The primary outcome was motor efficacy measured using Unified Parkinson's Disease Rating Scale (UPDRS) Part III or Movement Disorder Society-UPDRS Part III scores. Secondary outcomes included stimulation power and energy-related measures, stimulation ON-time, levodopa equivalent daily dose (LEDD), symptom-specific motor outcomes, gait and movement parameters, neurophysiological biomarkers, and safety. Compatible motor-outcome data were pooled using a random-effects model, and statistical heterogeneity was assessed using the I ² statistic. Secondary outcomes were synthesized narratively when differences in outcome measures or reporting precluded quantitative pooling.
Results: Seven studies were included in the qualitative synthesis, and five eligible study datasets contributed to the primary motor-outcome meta-analysis. Compared with cDBS, aDBS was associated with a statistically significant difference favoring improved motor scores [mean difference (MD) −2.74 points, 95% confidence interval (CI) − 5.20 to − 0.29; p = 0.03 ], with substantial heterogeneity ( I ² = 63% ). Sensitivity analysis restricted to four core crossover trials showed a similar direction of effect, although the difference was not statistically significant (MD −3.07 points, 95% CI − 6.27 to 0.13; p = 0.06; I ² = 70% ). Individual studies reported lower stimulation power or reduced stimulation delivery with aDBS, while one retrospective cohort reported a numerically greater reduction in LEDD. Some studies also suggested potential benefits in rigidity, bradykinesia-related performance, and selected gait measures; however, these findings were based on small samples and heterogeneous outcome assessments. Neurophysiological findings indicated possible differences in beta-band activity, but their clinical significance remained uncertain. Safety reporting was limited, and the available evidence did not establish a comparative advantage for either stimulation approach.
Conclusion: aDBS was associated with a statistically significant pooled difference favoring improved motor outcomes compared with cDBS. However, substantial heterogeneity and the non-significant sensitivity analysis limit confidence in the robustness and generalizability of this finding. Although preliminary evidence suggests potential reductions in stimulation delivery and benefits in selected motor domains, comparative advantages in medication requirements and safety remain unestablished. Larger, adequately powered comparative trials with longer follow-up, standardized outcome measures, and systematic safety reporting are needed to clarify the clinical effectiveness and long-term safety of aDBS in patients with PD.
Systematic review registration: https://www.crd.york.ac.uk/PROSPERO/view/CRD420261388549 , identifier: CRD420261388549.
Related
- Disease Duration Differentiates Freezing of Gait Response to Subthalamic and Nigral Stimulation for Parkinson's Disease in an Exploratory Multicenter Controlled Trial
- Hardware Sophistications in Subthalamic Nucleus Deep Brain Stimulation for Parkinson's Disease; Is the Juice Worth the Squeeze?
- Dopamine amplifies subthalamic long-latency responses to cortical stimulation in patients with Parkinson's disease.
- Assessing the effect of subthalamic stimulation on metaperception in obsessive-compulsive disorder
- Levodopa and Subthalamic Nucleus Deep Brain Stimulation Modulate Excitation/Inhibition Balance and the Neural Encoding of Isochronous Sequences in Persons With Parkinson's Disease
BibTeX
@article{hassan2026precision,
title = {{Precision neurostimulation in Parkinson's disease: a systematic review and meta-analysis of adaptive (aDBS) vs. conventional (cDBS) subthalamic stimulation on clinical efficacy and neural efficiency}},
author = {Muhammad Aftab Hassan and Marwah Nasir Ahmad and Saaid Mounzer Mouazen and Faisal Makki and Anushah Nadeem and Abdul Rahim Soroush and Muhammad Affan and Adnan Ahmed Badahdah},
journal = {Frontiers in Neurology},
year = {2026},
month = nov,
doi = {10.3389/fneur.2026.1901108},
url = {https://www.frontiersin.org/articles/10.3389/fneur.2026.1901108/full},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Precision neurostimulation in Parkinson's disease: a systematic review and meta-analysis of adaptive (aDBS) vs. conventional (cDBS) subthalamic stimulation on clinical efficacy and neural efficiency
AU - Muhammad Aftab Hassan
AU - Marwah Nasir Ahmad
AU - Saaid Mounzer Mouazen
AU - Faisal Makki
AU - Anushah Nadeem
AU - Abdul Rahim Soroush
AU - Muhammad Affan
AU - Adnan Ahmed Badahdah
PY - 2026
DA - 2026/11/18
JO - Frontiers in Neurology
DO - 10.3389/fneur.2026.1901108
UR - https://www.frontiersin.org/articles/10.3389/fneur.2026.1901108/full
AB - Background: Parkinson's disease (PD) is a progressive neurodegenerative disorder characterized by motor dysfunction and is commonly treated with subthalamic nucleus deep brain stimulation (STN-DBS) in patients with advanced motor complications. Conventional continuous deep brain stimulation (cDBS) delivers uninterrupted stimulation, whereas adaptive deep brain stimulation (aDBS) adjusts stimulation according to physiological biomarkers or other signals. Although aDBS may improve motor control while reducing stimulation delivery, its comparative effectiveness and safety remain uncertain. Methods: This systematic review and meta-analysis was conducted in accordance with PRISMA guidelines. PubMed, Embase, Scopus, and Cochrane CENTRAL were searched for eligible studies published between January 2013 and May 2026. Studies involving adults with idiopathic PD that compared aDBS with cDBS were included. The primary outcome was motor efficacy measured using Unified Parkinson's Disease Rating Scale (UPDRS) Part III or Movement Disorder Society-UPDRS Part III scores. Secondary outcomes included stimulation power and energy-related measures, stimulation ON-time, levodopa equivalent daily dose (LEDD), symptom-specific motor outcomes, gait and movement parameters, neurophysiological biomarkers, and safety. Compatible motor-outcome data were pooled using a random-effects model, and statistical heterogeneity was assessed using the I ² statistic. Secondary outcomes were synthesized narratively when differences in outcome measures or reporting precluded quantitative pooling. Results: Seven studies were included in the qualitative synthesis, and five eligible study datasets contributed to the primary motor-outcome meta-analysis. Compared with cDBS, aDBS was associated with a statistically significant difference favoring improved motor scores [mean difference (MD) −2.74 points, 95% confidence interval (CI) − 5.20 to − 0.29; p = 0.03 ], with substantial heterogeneity ( I ² = 63% ). Sensitivity analysis restricted to four core crossover trials showed a similar direction of effect, although the difference was not statistically significant (MD −3.07 points, 95% CI − 6.27 to 0.13; p = 0.06; I ² = 70% ). Individual studies reported lower stimulation power or reduced stimulation delivery with aDBS, while one retrospective cohort reported a numerically greater reduction in LEDD. Some studies also suggested potential benefits in rigidity, bradykinesia-related performance, and selected gait measures; however, these findings were based on small samples and heterogeneous outcome assessments. Neurophysiological findings indicated possible differences in beta-band activity, but their clinical significance remained uncertain. Safety reporting was limited, and the available evidence did not establish a comparative advantage for either stimulation approach. Conclusion: aDBS was associated with a statistically significant pooled difference favoring improved motor outcomes compared with cDBS. However, substantial heterogeneity and the non-significant sensitivity analysis limit confidence in the robustness and generalizability of this finding. Although preliminary evidence suggests potential reductions in stimulation delivery and benefits in selected motor domains, comparative advantages in medication requirements and safety remain unestablished. Larger, adequately powered comparative trials with longer follow-up, standardized outcome measures, and systematic safety reporting are needed to clarify the clinical effectiveness and long-term safety of aDBS in patients with PD. Systematic review registration: https://www.crd.york.ac.uk/PROSPERO/view/CRD420261388549 , identifier: CRD420261388549.
SN - 1664-2295
ER -