Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 26 min ago
Peer-reviewedCC BY-NC-NDJSES international

The effect of middle trapezius transfer using SwiveLocks anchors on glenohumeral translation and subacromial pressure in irreparable supraspinatus tears: a static and dynamic robotic biomechanical investigation

  1. 1The Steadman Philippon Research Institute, Department of Biomedical Engineering, Vail, CO, USA
  2. 2Department for Shoulder and Elbow Surgery, Schulthess Clinic, Zürich, Switzerland

Abstract

Background

To manage irreparable supraspinatus (SSP) tears, recent dynamic methods like the middle trapezius transfer (MTT) have been introduced; however, data on its efficacy in restoring physiological biomechanics are lacking.Purpose

The purpose was to assess the effects of MTT on superior humeral head translation and sub-acromial pressure in the setting of an irreparable SSP tear. It was hypothesized that a SSP tear would increase superior humeral head translation and sub-acromial pressure and that MTT would reduce superior humeral head translation and sub-acromial pressure.Methods

Ten fresh-frozen cadaveric shoulders were mounted to a 6-degree of freedom robotic arm (KUKA KR-60) and underwent biomechanical testing in 3 states: (1) intact, (2) simulated irreparable SSP tear, (3) MTT using SwiveLock anchors, loaded with 10N. Each shoulder was brought to 30°, 45°, 60°, 75°, and 90° of abduction (ABD), and 60 N of superior force was applied to the humerus at each position to simulate loaded glenohumeral ABD. Superior humeral displacement (mm) was measured by the robot and subacromial contact area (mm²) and peak contact pressure (MPa) were measured using a pressure sensor.Results

In the SSP defect state, the humeral head significantly translated superiorly across all ABD angles (+1.6 to +3.8 mm, P < .001), peak pressure significantly increased for ABD <90° compared to native (+0.48 MPa, P = .009 to +0.55, P = .030 MPa) and there was a significant decrease in subacromial contact area for ABD >30° (-15 mm², P = .001 to -40 mm², P < .001). MTT significantly reduced superior translation across all ABD angles (-0.7 mm, P = .048 to -1.6 mm, P < .001) but failed to restore native superior translation across all ABD angles (+0.9 mm, P = .020 to +2.3 mm, P < .001). MTT restored peak pressure conditions to the native state and a significant reduction in peak pressure was observed at 30° and 45° of ABD when compared to the SSP defect state (+0.33 MPa, P = .036 to +0.38 MPa, P = .041). After MTT, the contact area was significantly higher compared to the SSP defect state at 30° of ABD (+32 mm², P = .003), yet it failed to restore native contact area conditions at 60° (-22 mm², P = .045) and 90° of ABD (-20 mm², P < .001).Conclusion

MTT improved shoulder kinematics by reducing superior translation of the humeral head and subacromial peak pressure, and increasing subacromial contact area, partially restoring native conditions in the presence of an irreparable SSP tear.

Related

  1. Biomechanical effects of different suture pretension levels in suture-bridge repair of supraspinatus tendon tears: a finite element analysis
    Hongdong Wang, Yitong Li, Limin Mou +3
    Frontiers in Bioengineering and BiotechnologyPeer-reviewedCC BY 4.0Full textSurgery & anaesthesiaPMC
  2. Biomechanical impact of sagittal plane clavicle hook plate positioning on subacromial stress
    Jung-Min Lee, Jae-Hoo Lee
    Asia-Pacific Journal of Sports Medicine, Arthroscopy, Rehabilitation and TechnologyPeer-reviewedCC BY-NC-ND 4.0Full textSurgery & anaesthesiaPMC
  3. Feasibility of Intraoperative Anterior Reduction for the Treatment of Grade II Spondylolisthesis: A Biomechanical Investigation
    Deepak Reddy, Joshua P. McGuckin, Derek Yocum +4
    International Journal of Spine SurgeryPeer-reviewedLicence not statedFull textSurgery & anaesthesiaPMC
  4. Lateral Tibial Posterior Slope Induces Anterior Tibial Translation While Lateral-Medial Slope Difference Induces Internal Rotation: A Cadaveric Biomechanical Study
    Shuntaro Nejima, Jonathan Holt, Richard van Arkel +3
    The American Journal of Sports MedicinePeer-reviewedCC BY 4.0Full textSurgery & anaesthesiaPMC
  5. Diagnostic Musculoskeletal Ultrasound in the Evaluation of the Subacromial Bursa
    International journal of sports physical therapyPeer-reviewedCC BY-NCFull textGeneral medicineEurope PMC
BibTeX
@article{rupp2026effect,
  title = {{The effect of middle trapezius transfer using SwiveLocks anchors on glenohumeral translation and subacromial pressure in irreparable supraspinatus tears: a static and dynamic robotic biomechanical investigation}},
  author = {Marco-Christopher Rupp and Alexander R. Garcia and Amelia Drumm and Alex W. Brady and Rony Dey Hazra and Lucca Lacheta and Philipp Moroder and Matthew T. Provencher and Peter J. Millett},
  journal = {JSES international},
  year = {2026},
  month = sep,
  doi = {10.1016/j.jseint.2026.101797},
  url = {https://europepmc.org/article/PMC/PMC13753338},
  note = {CC BY-NC-ND},
}
RIS
TY  - JOUR
TI  - The effect of middle trapezius transfer using SwiveLocks anchors on glenohumeral translation and subacromial pressure in irreparable supraspinatus tears: a static and dynamic robotic biomechanical investigation
AU  - Marco-Christopher Rupp
AU  - Alexander R. Garcia
AU  - Amelia Drumm
AU  - Alex W. Brady
AU  - Rony Dey Hazra
AU  - Lucca Lacheta
AU  - Philipp Moroder
AU  - Matthew T. Provencher
AU  - Peter J. Millett
PY  - 2026
DA  - 2026/09/11
JO  - JSES international
DO  - 10.1016/j.jseint.2026.101797
UR  - https://europepmc.org/article/PMC/PMC13753338
AB  - Background  To manage irreparable supraspinatus (SSP) tears, recent dynamic methods like the middle trapezius transfer (MTT) have been introduced; however, data on its efficacy in restoring physiological biomechanics are lacking.Purpose  The purpose was to assess the effects of MTT on superior humeral head translation and sub-acromial pressure in the setting of an irreparable SSP tear. It was hypothesized that a SSP tear would increase superior humeral head translation and sub-acromial pressure and that MTT would reduce superior humeral head translation and sub-acromial pressure.Methods  Ten fresh-frozen cadaveric shoulders were mounted to a 6-degree of freedom robotic arm (KUKA KR-60) and underwent biomechanical testing in 3 states: (1) intact, (2) simulated irreparable SSP tear, (3) MTT using SwiveLock anchors, loaded with 10N. Each shoulder was brought to 30°, 45°, 60°, 75°, and 90° of abduction (ABD), and 60 N of superior force was applied to the humerus at each position to simulate loaded glenohumeral ABD. Superior humeral displacement (mm) was measured by the robot and subacromial contact area (mm²) and peak contact pressure (MPa) were measured using a pressure sensor.Results  In the SSP defect state, the humeral head significantly translated superiorly across all ABD angles (+1.6 to +3.8 mm, P < .001), peak pressure significantly increased for ABD <90° compared to native (+0.48 MPa, P = .009 to +0.55, P = .030 MPa) and there was a significant decrease in subacromial contact area for ABD >30° (-15 mm², P = .001 to -40 mm², P < .001). MTT significantly reduced superior translation across all ABD angles (-0.7 mm, P = .048 to -1.6 mm, P < .001) but failed to restore native superior translation across all ABD angles (+0.9 mm, P = .020 to +2.3 mm, P < .001). MTT restored peak pressure conditions to the native state and a significant reduction in peak pressure was observed at 30° and 45° of ABD when compared to the SSP defect state (+0.33 MPa, P = .036 to +0.38 MPa, P = .041). After MTT, the contact area was significantly higher compared to the SSP defect state at 30° of ABD (+32 mm², P = .003), yet it failed to restore native contact area conditions at 60° (-22 mm², P = .045) and 90° of ABD (-20 mm², P < .001).Conclusion  MTT improved shoulder kinematics by reducing superior translation of the humeral head and subacromial peak pressure, and increasing subacromial contact area, partially restoring native conditions in the presence of an irreparable SSP tear.
SN  - 2666-6383
ER  -