Biomechanical effects of different suture pretension levels in suture-bridge repair of supraspinatus tendon tears: a finite element analysis
- 1The Sixth Affiliated Hospital of Xinjiang Medical University, Urumqi, Xinjiang, China
- 2The Fourth Clinical Medical College of Xinjiang Medical University, Urumqi, Xinjiang, China
Abstract
Objective: The optimal initial suture pretension during suture-bridge repair of full-thickness supraspinatus tendon tears remains uncertain and is largely determined by the surgeon’s experience. This study aimed to evaluate the effects of different suture pretensions on the mechanical environment of the tendon-bone interface and to provide a biomechanical reference for intraoperative tension control.
Methods: A three-dimensional finite element model of the shoulder joint was reconstructed from computed tomography data of a healthy adult volunteer. A full-thickness supraspinatus tear was simulated and repaired using a double-row suture-bridge configuration. Seven total pretension levels (30–90 N, in 10 N increments) and three shoulder abduction positions (10°, 20°, and 30°) were combined to generate 21 loading conditions. The mean contact pressure, effective contact area, relative interfacial displacement, and tendon-side von Mises stress were analyzed.
Results: Increasing pretension increased the mean tendon-bone contact pressure at all abduction angles. At 20° of abduction, the mean contact pressure increased from 0.382 MPa to 0.856 MPa. The peak tendon-side von Mises stress also increased with pretension, reaching a maximum of 4.533 MPa in the 30°/90 N condition. The effective contact area changed only slightly at 10° of abduction, decreased from 181.4 mm2 to 169.5 mm2 at 20°, and reached relatively high values at 50–60 N at 30°. High-stress regions were mainly concentrated around the medial-row suture perforation sites and expanded as pretension increased.
Conclusion: Suture pretension improved tendon-bone compression and initial interfacial stability, but higher pretension increased local pressure and tendon stress concentration. Within the tested configurations, 50–60 N represented an intermediate, condition-dependent range rather than a universal clinical target.
Related
- The effect of middle trapezius transfer using SwiveLocks anchors on glenohumeral translation and subacromial pressure in irreparable supraspinatus tears: a static and dynamic robotic biomechanical investigation
- Chest tube fixation strength depends on suture caliber and fixation technique rather than tube diameter: a biomechanical cadaver study
- Short Expandable-Wing Suture Anchors for Tibial Eminence Avulsion Fracture Fixation: Effects of Solid Versus Additively Manufactured Lattice Wings on Biomechanical Performance and Cytocompatibility.
- A simple independent high-strength suture augmentation significantly improves tendon biomechanical properties in anterior cruciate ligament reconstruction
- Biomechanical comparison of stand-alone interbody bone grafting versus cage implantation in ULIF: a finite element analysis
BibTeX
@article{wang2026biomechanical,
title = {{Biomechanical effects of different suture pretension levels in suture-bridge repair of supraspinatus tendon tears: a finite element analysis}},
author = {Hongdong Wang and Yitong Li and Limin Mou and Chun Ge and Yifei Huang and Rongxin Sun},
journal = {Frontiers in Bioengineering and Biotechnology},
year = {2026},
month = nov,
doi = {10.3389/fbioe.2026.1935045},
url = {https://doi.org/10.3389/fbioe.2026.1935045},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Biomechanical effects of different suture pretension levels in suture-bridge repair of supraspinatus tendon tears: a finite element analysis
AU - Hongdong Wang
AU - Yitong Li
AU - Limin Mou
AU - Chun Ge
AU - Yifei Huang
AU - Rongxin Sun
PY - 2026
DA - 2026/11/02
JO - Frontiers in Bioengineering and Biotechnology
DO - 10.3389/fbioe.2026.1935045
UR - https://doi.org/10.3389/fbioe.2026.1935045
AB - Objective: The optimal initial suture pretension during suture-bridge repair of full-thickness supraspinatus tendon tears remains uncertain and is largely determined by the surgeon’s experience. This study aimed to evaluate the effects of different suture pretensions on the mechanical environment of the tendon-bone interface and to provide a biomechanical reference for intraoperative tension control. Methods: A three-dimensional finite element model of the shoulder joint was reconstructed from computed tomography data of a healthy adult volunteer. A full-thickness supraspinatus tear was simulated and repaired using a double-row suture-bridge configuration. Seven total pretension levels (30–90 N, in 10 N increments) and three shoulder abduction positions (10°, 20°, and 30°) were combined to generate 21 loading conditions. The mean contact pressure, effective contact area, relative interfacial displacement, and tendon-side von Mises stress were analyzed. Results: Increasing pretension increased the mean tendon-bone contact pressure at all abduction angles. At 20° of abduction, the mean contact pressure increased from 0.382 MPa to 0.856 MPa. The peak tendon-side von Mises stress also increased with pretension, reaching a maximum of 4.533 MPa in the 30°/90 N condition. The effective contact area changed only slightly at 10° of abduction, decreased from 181.4 mm2 to 169.5 mm2 at 20°, and reached relatively high values at 50–60 N at 30°. High-stress regions were mainly concentrated around the medial-row suture perforation sites and expanded as pretension increased. Conclusion: Suture pretension improved tendon-bone compression and initial interfacial stability, but higher pretension increased local pressure and tendon stress concentration. Within the tested configurations, 50–60 N represented an intermediate, condition-dependent range rather than a universal clinical target.
SN - 2296-4185
ER -