Skip to content
DraconiticResearch
Search Sources API
197,768 studies31 sourcesUpdated 14 min ago
Peer-reviewedCC BYJournal of ophthalmology

Hydrophobic Acrylic Trifocal IOL in Post-Laser Refractive Surgery Eyes: Visual Performance, Predictability, and Patient-Reported Outcomes.

4 affiliations
  1. 1Department of Ophthalmology Samsung Medical Center Sungkyunkwan University School of Medicine 81 Irwon-ro, Gangnam-gu Seoul 06351 South Korea skku.edu.
  2. 2The New York University College of Arts and Science 70 Washington Square South New York 10012 New York USA.
  3. 3First Samsung Eye Clinic 22, Seocho-daero 78-gil, Seocho-gu Seoul South Korea.
  4. 4Samsung Advanced Institute for Health Sciences and Technology Sungkyunkwan University Seoul South Korea skku.edu.

Abstract

Purpose

To evaluate clinical and patient-reported outcomes of the Clareon PanOptix (CP) hydrophobic acrylic trifocal IOL in eyes with previous myopic laser refractive surgery (LRS).Methods

This single-center, ambispective study included 94 eyes of 47 patients with previous myopic LRS undergoing CP implantation. At 6 months, monocular visual acuity (VA), refraction, and refractive outcomes were assessed. Prediction accuracy was compared using Barrett True-K and Haigis-L with conventional keratometry (CK) or total keratometry (TK) on the IOLMaster 700 and Barrett True-K with CK or TK on the Argos; Argos TK incorporated Pentacam-measured posterior corneal astigmatism. Spectacle dependence, satisfaction, and visual disturbances were assessed. Correlations between preoperative corneal higher-order aberrations (HOAs) and postoperative outcomes were analyzed.Results

Mean uncorrected VAs were 0.028 ± 0.087 logMAR for distance, 0.177 ± 0.130 logMAR for intermediate, and 0.093 ± 0.137 logMAR for near. The mean postoperative spherical equivalent was -0.142 ± 0.375 D, with 81% of eyes within ±0.50 D of emmetropia. In a retrospective comparison of IOL power calculation methods, Barrett True-K with TK on the IOLMaster 700 yielded the highest observed proportion of eyes within ±0.50 D of the intended target (78.7%). After Holm-Bonferroni correction, preoperative corneal HOA RMS and nonspherical HOA RMS at a 3.0-mm diameter were associated with uncorrected distance VA, whereas corneal HOAs at larger analysis diameters (5.0-6.0 mm) were associated with postoperative visual disturbances. Patients reported high satisfaction (3.09 ± 0.62) and complete spectacle independence for distance and intermediate vision.Conclusions

The CP trifocal IOL is an effective option for presbyopia correction in post-myopic LRS eyes meeting predefined preoperative corneal aberration criteria. Refractive predictability depended on device-specific formula-keratometry combinations, with Barrett True-K yielding the highest observed ±0.50 D rates with TK (IOLMaster 700) and with CK (Argos). Corneal HOA analysis at specified measurement diameters may further guide patient selection and counseling.

Related

  1. Visual, refractive and patient-reported outcomes after two trifocal intraocular lens designs: a 12-month comparative cohort study.
    Bora Deniz Argon, Enes Soyyiğit
    BMC ophthalmologyPeer-reviewedCC BY-NC-NDFull textGeneral medicineEurope PMCDOAJ
  2. Effect of residual spherical equivalent on visual outcomes of trifocal intraocular lens implantation in patients with cataracts across different refractive states
    Jin Zhou, Xue Zhan, HongLin Ye +2
    Scientific ReportsPeer-reviewedCC BYFull textGeneral medicineDOAJ
  3. Three-Year Functional Vision, Longitudinal Refractive Outcomes, and Patient-Reported Outcomes After Bilateral Implantation of the Extend Bessel-Optics Intraocular Lens: An Independent Real-World Ambispective Study
    Medicina (Kaunas, Lithuania)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
  4. Prevalence of self-reported dry eye symptoms after refractive surgery among Saudi adults: A cross-sectional survey
    Mahmood J Showail, Abubakr S Alzwaihri, Eid A Almasoudi +4
    PLOS OnePeer-reviewedCC BYFull textGeneral biologyEpidemiology & public healthPLOSEurope PMCPMC
  5. Self-reported chewing or swallowing problems and episodic memory performance in older Americans: a longitudinal cohort study
    Fei He, Chonghao Yao, Xuteng Kang +3
    Frontiers in aging neurosciencePeer-reviewedCC BYFull textGeneral medicineEurope PMC
BibTeX
@article{goh2026hydrophobic,
  title = {{Hydrophobic Acrylic Trifocal IOL in Post-Laser Refractive Surgery Eyes: Visual Performance, Predictability, and Patient-Reported Outcomes.}},
  author = {Yong Hyu Goh and Yoon Seong Choi and Sungho Choi and Dong Hui Lim and Sung Jin Na and Deok Jo Nam},
  journal = {Journal of ophthalmology},
  year = {2026},
  month = oct,
  doi = {10.1155/joph/7762608},
  url = {https://europepmc.org/article/MED/42910159},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Hydrophobic Acrylic Trifocal IOL in Post-Laser Refractive Surgery Eyes: Visual Performance, Predictability, and Patient-Reported Outcomes.
AU  - Yong Hyu Goh
AU  - Yoon Seong Choi
AU  - Sungho Choi
AU  - Dong Hui Lim
AU  - Sung Jin Na
AU  - Deok Jo Nam
PY  - 2026
DA  - 2026/10/21
JO  - Journal of ophthalmology
DO  - 10.1155/joph/7762608
UR  - https://europepmc.org/article/MED/42910159
AB  - Purpose  To evaluate clinical and patient-reported outcomes of the Clareon PanOptix (CP) hydrophobic acrylic trifocal IOL in eyes with previous myopic laser refractive surgery (LRS).Methods  This single-center, ambispective study included 94 eyes of 47 patients with previous myopic LRS undergoing CP implantation. At 6 months, monocular visual acuity (VA), refraction, and refractive outcomes were assessed. Prediction accuracy was compared using Barrett True-K and Haigis-L with conventional keratometry (CK) or total keratometry (TK) on the IOLMaster 700 and Barrett True-K with CK or TK on the Argos; Argos TK incorporated Pentacam-measured posterior corneal astigmatism. Spectacle dependence, satisfaction, and visual disturbances were assessed. Correlations between preoperative corneal higher-order aberrations (HOAs) and postoperative outcomes were analyzed.Results  Mean uncorrected VAs were 0.028 ± 0.087 logMAR for distance, 0.177 ± 0.130 logMAR for intermediate, and 0.093 ± 0.137 logMAR for near. The mean postoperative spherical equivalent was -0.142 ± 0.375 D, with 81% of eyes within ±0.50 D of emmetropia. In a retrospective comparison of IOL power calculation methods, Barrett True-K with TK on the IOLMaster 700 yielded the highest observed proportion of eyes within ±0.50 D of the intended target (78.7%). After Holm-Bonferroni correction, preoperative corneal HOA RMS and nonspherical HOA RMS at a 3.0-mm diameter were associated with uncorrected distance VA, whereas corneal HOAs at larger analysis diameters (5.0-6.0 mm) were associated with postoperative visual disturbances. Patients reported high satisfaction (3.09 ± 0.62) and complete spectacle independence for distance and intermediate vision.Conclusions  The CP trifocal IOL is an effective option for presbyopia correction in post-myopic LRS eyes meeting predefined preoperative corneal aberration criteria. Refractive predictability depended on device-specific formula-keratometry combinations, with Barrett True-K yielding the highest observed ±0.50 D rates with TK (IOLMaster 700) and with CK (Argos). Corneal HOA analysis at specified measurement diameters may further guide patient selection and counseling.
SN  - 2090-004X
SN  - 2090-0058
ER  -