Digital three-dimensional planning combined with 3D-printed patient-specific guide-assisted step-cut osteotomy for correction of old cubitus varus deformity: a case report.
- 1Department of Upper Limb, Mianyang Orthopaedic Hospital, Mianyang, Sichuan, China.
Abstract
Cubitus varus is the most common long-term complication following supracondylar humeral fractures. Although traditional step-cut osteotomy yields reliable clinical outcomes, the intraoperative osteotomy direction and angle remain largely dependent on the surgeon's experience, resulting in suboptimal precision. Although digital three-dimensional (3D) planning and 3D-printed patient-specific guides have been shown to improve osteotomy accuracy, their application in adolescent patients with long-standing cubitus varus deformity has rarely been reported. We report an 18-year-old male patient who developed progressive cubitus varus deformity 13 years after conservative treatment of a right supracondylar humeral fracture. Preoperatively, the carrying angle was -19°, with mildly restricted elbow motion and no ulnar nerve symptoms. Using mirror-image-based 3D digital planning, we designed and 3D-printed a patient-specific step-cut osteotomy guide and performed corrective osteotomy with lateral locking plate fixation. Intraoperatively, the guide was stably apposed to the bone surface, enabling precise execution of the osteotomy without displacement or interference. At 12-month follow-up, both the carrying angle and humeral-elbow-wrist angle had improved from -19° to 6.5°, elbow flexion-extension range improved from 5°-120° to 0°-135°, and the Mayo Elbow Performance Score was 95. No complications such as nonunion or nerve injury occurred, and the patient was satisfied with the surgical outcome. The combination of digital 3D planning and 3D-printed guide-assisted step-cut osteotomy may significantly enhance osteotomy accuracy and surgical safety, offering an effective approach for treating long-standing cubitus varus in adolescents. Nevertheless, given that this is a single-case report, broader studies are warranted to confirm its advantages.
Related
- A comparative study of distal chevron osteotomy and minimally invasive surgery for surgical correction of hallux valgus deformity.
- A system-independent 3D coordinate–based planning method for hexapod deformity correction: a synthetic bone model study and preliminary clinical experience
- Combined Management of Meniscus Root Tear and High Tibial Osteotomy: A Surgical Strategy Using 3‐Dimensional Printing
- Effects of vertebral shortening during corrective osteotomy for spinal deformity on spinal cord biomechanics and cerebrospinal fluid-anterior spinal artery fluid-structure interaction
- Improved range of motion following correction osteotomy for varus malunited proximal humerus fractures with 3-dimensional planned cutting guides: a case series
BibTeX
@article{huang2026digital,
title = {{Digital three-dimensional planning combined with 3D-printed patient-specific guide-assisted step-cut osteotomy for correction of old cubitus varus deformity: a case report.}},
author = {Xiaofan Huang and Fulin Tang and Jialin Zhuang and Weikun Li},
journal = {Frontiers in surgery},
year = {2026},
month = sep,
doi = {10.3389/fsurg.2026.1926289},
url = {https://europepmc.org/article/MED/42840154},
note = {CC BY},
}
RIS
TY - JOUR
TI - Digital three-dimensional planning combined with 3D-printed patient-specific guide-assisted step-cut osteotomy for correction of old cubitus varus deformity: a case report.
AU - Xiaofan Huang
AU - Fulin Tang
AU - Jialin Zhuang
AU - Weikun Li
PY - 2026
DA - 2026/09/22
JO - Frontiers in surgery
DO - 10.3389/fsurg.2026.1926289
UR - https://europepmc.org/article/MED/42840154
AB - Cubitus varus is the most common long-term complication following supracondylar humeral fractures. Although traditional step-cut osteotomy yields reliable clinical outcomes, the intraoperative osteotomy direction and angle remain largely dependent on the surgeon's experience, resulting in suboptimal precision. Although digital three-dimensional (3D) planning and 3D-printed patient-specific guides have been shown to improve osteotomy accuracy, their application in adolescent patients with long-standing cubitus varus deformity has rarely been reported. We report an 18-year-old male patient who developed progressive cubitus varus deformity 13 years after conservative treatment of a right supracondylar humeral fracture. Preoperatively, the carrying angle was -19°, with mildly restricted elbow motion and no ulnar nerve symptoms. Using mirror-image-based 3D digital planning, we designed and 3D-printed a patient-specific step-cut osteotomy guide and performed corrective osteotomy with lateral locking plate fixation. Intraoperatively, the guide was stably apposed to the bone surface, enabling precise execution of the osteotomy without displacement or interference. At 12-month follow-up, both the carrying angle and humeral-elbow-wrist angle had improved from -19° to 6.5°, elbow flexion-extension range improved from 5°-120° to 0°-135°, and the Mayo Elbow Performance Score was 95. No complications such as nonunion or nerve injury occurred, and the patient was satisfied with the surgical outcome. The combination of digital 3D planning and 3D-printed guide-assisted step-cut osteotomy may significantly enhance osteotomy accuracy and surgical safety, offering an effective approach for treating long-standing cubitus varus in adolescents. Nevertheless, given that this is a single-case report, broader studies are warranted to confirm its advantages.
SN - 2296-875X
ER -