Beyond Mean Surgically Induced Astigmatism: A Directional Reproducibility Framework for Toric IOL Calculation

4 affiliations
  1. 1Department of Glaucoma and Neuro-Ophthalmology, Hospital Arruzafa, 14012 Cordoba, Spain
  2. 2Department of Information Technology, Hospital Arruzafa, 14012 Cordoba, Spain
  3. 3Department of Condensed Matter Physics, Optics Area, Faculty of Pharmacy, University of Seville, 41012 Seville, Spain
  4. 4Department of Optometry, Hospital Arruzafa, 14012 Cordoba, Spain

Abstract

Background: Surgeon-specific surgically induced astigmatism (SIA) is commonly considered in toric intraocular lens (IOL) calculations; however, a mean SIA vector does not indicate whether the underlying surgical effect is reproducible across cases. Methods: We developed a quantitative framework based on axial circular statistics to characterize SIA reproducibility. Directional consistency was assessed using the mean resultant length (R), while a magnitude-weighted extension (Rw) quantified whether the astigmatic power was concentrated around a predominant direction. Variability in scalar SIA magnitude was independently assessed using the coefficient of variation (CV). Theoretically derived operational thresholds were established from geometric and relative-dispersion criteria and integrated into a decision framework. A controlled synthetic simulation using Barrett Toric calculations compared higher- and lower-consistency SIA distributions across 20 matched ocular profiles at each of two centroid magnitudes, estimating final theoretical residual astigmatism under a common-plane approximation. Results: R and Rw provide complementary normalized measures of directional reproducibility, whereas CV captures variability in SIA magnitude. A threshold of 0.70 for R and Rw was geometrically derived from 1/2, corresponding to a symmetric ±22.5° deviation around the predominant clinical astigmatic axis. CV thresholds of <20%, 20–50%, and >50% were proposed to represent low, intermediate, and high relative magnitude variability, respectively. Higher SIA consistency yielded lower mean final theoretical residual astigmatism at both centroid magnitudes: 0.25 versus 0.51 D for the 0.26 D centroid and 0.42 versus 0.90 D for the 0.55 D centroid. Conclusions: Combined assessment of R, Rw, and CV provides a quantitative framework for determining whether a mean SIA adequately represents its underlying vector distribution before incorporation into toric IOL calculators. These theoretically derived thresholds require subsequent clinical validation.

Related

  1. Vector Analysis of Surgically Induced Astigmatism for Individualized Superior Incision Selection in ICL Surgery: Real‐World Outcomes of Corneal and Limbal Incisions Stratified by Preoperative Astigmatism
    Shuaifei Li, Lingling Xu, Mingyang Hu +2
    Journal of OphthalmologyPeer-reviewedCC BY 4.0Full textGeneral medicinePMC
  2. Surgically induced astigmatism after phacotrabeculectomy: a prospective observational study at ECWA Eye Hospital, Kano.
    Olalekan Adebayo Ogundare, Abdu Lawan, Mayor Orezime Atima +5
    BMC ophthalmologyPeer-reviewedCC BY-NC-NDFull textGeneral medicineEurope PMCPMC
  3. Nutrient Calculation Accuracy, Expert-Rated Clinical Appropriateness and Safety Indicators, and Reproducibility of Large Language Model-Generated Diet Plans for Polyendocrine Metabolic Ovarian Syndrome: A Real-Case-Based Evaluation
    Ayşenur Çalık, Pınar Ece Demiray, Ayşe Betül Bilen +2
    NutrientsPeer-reviewedCC BYFull textNutritionEurope PMC
  4. From Repeatability to Reproducibility in Quantitative Low-Field MRI: A Metrology-Informed Framework for Phantom Evidence.
    Helena Kolarova, Jitka Hanusova, Jan Kavalirek +2
    Journal of imagingPeer-reviewedCC BYFull textMedical imaging & radiologyEurope PMC
  5. A statistical framework for evaluating the repeatability and reproducibility of large language models
    Cathy Shyr, Boyu Ren, Chih-Yuan Hsu +12
    Journal of the American Medical Informatics AssociationPeer-reviewedCC BYFull text46 citedEpidemiology & public healthOpenAlex
BibTeX
@article{labordaguirao2026beyond,
  title = {{Beyond Mean Surgically Induced Astigmatism: A Directional Reproducibility Framework for Toric IOL Calculation}},
  author = {Teresa Laborda-Guirao and Christian Hierro-Cordón and José María Sánchez-González and Timoteo González-Cruces},
  journal = {Journal of Clinical Medicine},
  year = {2026},
  month = nov,
  doi = {10.3390/jcm15228999},
  url = {https://www.mdpi.com/2077-0383/15/22/8999},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Beyond Mean Surgically Induced Astigmatism: A Directional Reproducibility Framework for Toric IOL Calculation
AU  - Teresa Laborda-Guirao
AU  - Christian Hierro-Cordón
AU  - José María Sánchez-González
AU  - Timoteo González-Cruces
PY  - 2026
DA  - 2026/11/01
JO  - Journal of Clinical Medicine
DO  - 10.3390/jcm15228999
UR  - https://www.mdpi.com/2077-0383/15/22/8999
AB  - Background: Surgeon-specific surgically induced astigmatism (SIA) is commonly considered in toric intraocular lens (IOL) calculations; however, a mean SIA vector does not indicate whether the underlying surgical effect is reproducible across cases. Methods: We developed a quantitative framework based on axial circular statistics to characterize SIA reproducibility. Directional consistency was assessed using the mean resultant length (R), while a magnitude-weighted extension (Rw) quantified whether the astigmatic power was concentrated around a predominant direction. Variability in scalar SIA magnitude was independently assessed using the coefficient of variation (CV). Theoretically derived operational thresholds were established from geometric and relative-dispersion criteria and integrated into a decision framework. A controlled synthetic simulation using Barrett Toric calculations compared higher- and lower-consistency SIA distributions across 20 matched ocular profiles at each of two centroid magnitudes, estimating final theoretical residual astigmatism under a common-plane approximation. Results: R and Rw provide complementary normalized measures of directional reproducibility, whereas CV captures variability in SIA magnitude. A threshold of 0.70 for R and Rw was geometrically derived from 1/2, corresponding to a symmetric ±22.5° deviation around the predominant clinical astigmatic axis. CV thresholds of <20%, 20–50%, and >50% were proposed to represent low, intermediate, and high relative magnitude variability, respectively. Higher SIA consistency yielded lower mean final theoretical residual astigmatism at both centroid magnitudes: 0.25 versus 0.51 D for the 0.26 D centroid and 0.42 versus 0.90 D for the 0.55 D centroid. Conclusions: Combined assessment of R, Rw, and CV provides a quantitative framework for determining whether a mean SIA adequately represents its underlying vector distribution before incorporation into toric IOL calculators. These theoretically derived thresholds require subsequent clinical validation.
SN  - 2077-0383
ER  -