Beyond Mean Surgically Induced Astigmatism: A Directional Reproducibility Framework for Toric IOL Calculation
4 affiliations
- 1Department of Glaucoma and Neuro-Ophthalmology, Hospital Arruzafa, 14012 Cordoba, Spain
- 2Department of Information Technology, Hospital Arruzafa, 14012 Cordoba, Spain
- 3Department of Condensed Matter Physics, Optics Area, Faculty of Pharmacy, University of Seville, 41012 Seville, Spain
- 4Department of Optometry, Hospital Arruzafa, 14012 Cordoba, Spain
Abstract
Background: Surgeon-specific surgically induced astigmatism (SIA) is commonly considered in toric intraocular lens (IOL) calculations; however, a mean SIA vector does not indicate whether the underlying surgical effect is reproducible across cases. Methods: We developed a quantitative framework based on axial circular statistics to characterize SIA reproducibility. Directional consistency was assessed using the mean resultant length (R), while a magnitude-weighted extension (Rw) quantified whether the astigmatic power was concentrated around a predominant direction. Variability in scalar SIA magnitude was independently assessed using the coefficient of variation (CV). Theoretically derived operational thresholds were established from geometric and relative-dispersion criteria and integrated into a decision framework. A controlled synthetic simulation using Barrett Toric calculations compared higher- and lower-consistency SIA distributions across 20 matched ocular profiles at each of two centroid magnitudes, estimating final theoretical residual astigmatism under a common-plane approximation. Results: R and Rw provide complementary normalized measures of directional reproducibility, whereas CV captures variability in SIA magnitude. A threshold of 0.70 for R and Rw was geometrically derived from 1/2, corresponding to a symmetric ±22.5° deviation around the predominant clinical astigmatic axis. CV thresholds of <20%, 20–50%, and >50% were proposed to represent low, intermediate, and high relative magnitude variability, respectively. Higher SIA consistency yielded lower mean final theoretical residual astigmatism at both centroid magnitudes: 0.25 versus 0.51 D for the 0.26 D centroid and 0.42 versus 0.90 D for the 0.55 D centroid. Conclusions: Combined assessment of R, Rw, and CV provides a quantitative framework for determining whether a mean SIA adequately represents its underlying vector distribution before incorporation into toric IOL calculators. These theoretically derived thresholds require subsequent clinical validation.
Related
- Vector Analysis of Surgically Induced Astigmatism for Individualized Superior Incision Selection in ICL Surgery: Real‐World Outcomes of Corneal and Limbal Incisions Stratified by Preoperative Astigmatism
- Surgically induced astigmatism after phacotrabeculectomy: a prospective observational study at ECWA Eye Hospital, Kano.
- Nutrient Calculation Accuracy, Expert-Rated Clinical Appropriateness and Safety Indicators, and Reproducibility of Large Language Model-Generated Diet Plans for Polyendocrine Metabolic Ovarian Syndrome: A Real-Case-Based Evaluation
- From Repeatability to Reproducibility in Quantitative Low-Field MRI: A Metrology-Informed Framework for Phantom Evidence.
- A statistical framework for evaluating the repeatability and reproducibility of large language models
BibTeX
@article{labordaguirao2026beyond,
title = {{Beyond Mean Surgically Induced Astigmatism: A Directional Reproducibility Framework for Toric IOL Calculation}},
author = {Teresa Laborda-Guirao and Christian Hierro-Cordón and José María Sánchez-González and Timoteo González-Cruces},
journal = {Journal of Clinical Medicine},
year = {2026},
month = nov,
doi = {10.3390/jcm15228999},
url = {https://www.mdpi.com/2077-0383/15/22/8999},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Beyond Mean Surgically Induced Astigmatism: A Directional Reproducibility Framework for Toric IOL Calculation
AU - Teresa Laborda-Guirao
AU - Christian Hierro-Cordón
AU - José María Sánchez-González
AU - Timoteo González-Cruces
PY - 2026
DA - 2026/11/01
JO - Journal of Clinical Medicine
DO - 10.3390/jcm15228999
UR - https://www.mdpi.com/2077-0383/15/22/8999
AB - Background: Surgeon-specific surgically induced astigmatism (SIA) is commonly considered in toric intraocular lens (IOL) calculations; however, a mean SIA vector does not indicate whether the underlying surgical effect is reproducible across cases. Methods: We developed a quantitative framework based on axial circular statistics to characterize SIA reproducibility. Directional consistency was assessed using the mean resultant length (R), while a magnitude-weighted extension (Rw) quantified whether the astigmatic power was concentrated around a predominant direction. Variability in scalar SIA magnitude was independently assessed using the coefficient of variation (CV). Theoretically derived operational thresholds were established from geometric and relative-dispersion criteria and integrated into a decision framework. A controlled synthetic simulation using Barrett Toric calculations compared higher- and lower-consistency SIA distributions across 20 matched ocular profiles at each of two centroid magnitudes, estimating final theoretical residual astigmatism under a common-plane approximation. Results: R and Rw provide complementary normalized measures of directional reproducibility, whereas CV captures variability in SIA magnitude. A threshold of 0.70 for R and Rw was geometrically derived from 1/2, corresponding to a symmetric ±22.5° deviation around the predominant clinical astigmatic axis. CV thresholds of <20%, 20–50%, and >50% were proposed to represent low, intermediate, and high relative magnitude variability, respectively. Higher SIA consistency yielded lower mean final theoretical residual astigmatism at both centroid magnitudes: 0.25 versus 0.51 D for the 0.26 D centroid and 0.42 versus 0.90 D for the 0.55 D centroid. Conclusions: Combined assessment of R, Rw, and CV provides a quantitative framework for determining whether a mean SIA adequately represents its underlying vector distribution before incorporation into toric IOL calculators. These theoretically derived thresholds require subsequent clinical validation.
SN - 2077-0383
ER -