Skip to content
DraconiticResearch
Search Sources API
197,787 studies31 sourcesUpdated 45 min ago
PreprintCC BY-NC-ND 4.0arXiv

Dynamic Modulated Arc Therapy (DMAT): A Time Aware, Modulation Steered Optimization Framework for Next Generation Radiotherapy Delivery

1 more authors

Abstract

Background: Conventional VMAT optimization treats delivery time and deliverability as emergent properties of control-point-centric models that ignore finite acceleration and other dynamic limits. As linacs gain axis speed and dose rate, the plan quality-time trade-off must become explicit and steerable. Purpose: To introduce Dynamic Modulated Arc Therapy (DMAT), a time-aware, modulation-steered framework that jointly optimizes dosimetric quality, delivery time, and modulation complexity. Methods: DMAT couples direct machine emulation (axis synchronization, finite acceleration), dynamic modulation control, and clinical metrics used directly as cost functions. A user-selected modulation level (-3 to +3) governs leaf-travel allowance, total MU, aperture complexity, and control-point (CP) density. Plans are generated by progressive-resolution optimization alternating dosimetric with sequencing/deliverability updates, with non-uniform CP redistribution and complexity-reducing post-processing. DMAT was evaluated on head-and-neck, lung SBRT, and prostate SBRT cases using a hypothetical accelerated system (2.5 RPM gantry, 6.25 cm/s MLC, 3000 MU/min). Results: Increasing modulation level raised modulation surrogates (MU/Gy, aperture complexity) and delivery time, with additional CPs concentrated in arc sectors where finer angular resolution was most beneficial. The trade-off was site dependent: head-and-neck gained substantial plan quality, whereas prostate and lung SBRT gained little beyond baseline. Negative levels predictably shortened delivery time at a fixed CP budget, with quantifiable quality loss. Conclusions: DMAT co-optimizes plan quality and modulation complexity under machine-aware timing and explicit user control, making quality-time trade-offs transparent and navigable and supporting time-constrained workflows such as motion management and adaptive radiotherapy.

Versions

Related

  1. Tangential volumetric modulated arc therapy reduces cardiac and contralateral low-dose exposure compared with continuous volumetric modulated arc therapy in postoperative breast radiotherapy
    Anne Caroline Knöchelmann, Mirko Fischer, Kathrin Burchardt +2
    Physics and Imaging in Radiation OncologyPeer-reviewedCC BYFull textApplied physics & instrumentationDOAJ
  2. Dosimetric Comparison of Intensity-Modulated Radiotherapy and Four-Field Three-Dimensional Conformal Radiotherapy in the Management of Prostate Cancer: A Retrospective Dual-Centre Analysis
    Alaa AbdAllah, wafaa mohamed, Amani Saber +1
    Minia Journal of Medical ResearchPeer-reviewedCC BYFull textApplied physics & instrumentationDOAJ
  3. Rayleigh Backscattering Reflectometry using Incoherent Frequency-Modulated Continuous Wave and Bidirectional Electro-Optic Modulation
    Miguel Cuenca, Haroldo Maestre Vicente, Carlos Fernandez-Pousa
    Optics ExpressPeer-reviewedLicence not statedOptics & photonicsCrossref
  4. Comparative Dosimetric Evaluation of Tomotherapy with a 1-cm Field Width versus Volumetric-modulated Arc Therapy for Whole-brain Radiotherapy with Hippocampal Avoidance
    Sankar Sekar, R. Leel Malar, Dinesh Babu A +4
    Journal of Medical PhysicsPeer-reviewedCC BY-NC-SAFull textApplied physics & instrumentationDOAJ
  5. Nonlinear pluggable optics: Digital signal processing-free Intensity Modulated Direct Detection links using analog photonic Next Generation Reservoir Computing
    Nicholas Cox, Joseph Murray, Ross Schermer +6
    Optics ExpressPeer-reviewedLicence not statedOptics & photonicsCrossref
BibTeX
@misc{li2026dynamic,
  title = {{Dynamic Modulated Arc Therapy (DMAT): A Time Aware, Modulation Steered Optimization Framework for Next Generation Radiotherapy Delivery}},
  author = {Taoran Li and Esa Kuusela and Emmi Ruokokoski and Heini Hyvönen and Jerry Jaboin and Mirko Myllykoski and Jussi Nurminen and Riku Paananen and Jarkko Peltola and Marko Rusanen and Martin Sabel and Kevin Moore and Christopher Boylan},
  howpublished = {arXiv},
  year = {2026},
  month = sep,
  doi = {10.48550/arxiv.2605.12891},
  eprint = {2605.12891},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2605.12891},
  note = {CC BY-NC-ND 4.0},
}
RIS
TY  - UNPB
TI  - Dynamic Modulated Arc Therapy (DMAT): A Time Aware, Modulation Steered Optimization Framework for Next Generation Radiotherapy Delivery
AU  - Taoran Li
AU  - Esa Kuusela
AU  - Emmi Ruokokoski
AU  - Heini Hyvönen
AU  - Jerry Jaboin
AU  - Mirko Myllykoski
AU  - Jussi Nurminen
AU  - Riku Paananen
AU  - Jarkko Peltola
AU  - Marko Rusanen
AU  - Martin Sabel
AU  - Kevin Moore
AU  - Christopher Boylan
PY  - 2026
DA  - 2026/09/02
PB  - arXiv
DO  - 10.48550/arxiv.2605.12891
UR  - https://arxiv.org/abs/2605.12891
AB  - Background: Conventional VMAT optimization treats delivery time and deliverability as emergent properties of control-point-centric models that ignore finite acceleration and other dynamic limits. As linacs gain axis speed and dose rate, the plan quality-time trade-off must become explicit and steerable. Purpose: To introduce Dynamic Modulated Arc Therapy (DMAT), a time-aware, modulation-steered framework that jointly optimizes dosimetric quality, delivery time, and modulation complexity. Methods: DMAT couples direct machine emulation (axis synchronization, finite acceleration), dynamic modulation control, and clinical metrics used directly as cost functions. A user-selected modulation level (-3 to +3) governs leaf-travel allowance, total MU, aperture complexity, and control-point (CP) density. Plans are generated by progressive-resolution optimization alternating dosimetric with sequencing/deliverability updates, with non-uniform CP redistribution and complexity-reducing post-processing. DMAT was evaluated on head-and-neck, lung SBRT, and prostate SBRT cases using a hypothetical accelerated system (2.5 RPM gantry, 6.25 cm/s MLC, 3000 MU/min). Results: Increasing modulation level raised modulation surrogates (MU/Gy, aperture complexity) and delivery time, with additional CPs concentrated in arc sectors where finer angular resolution was most beneficial. The trade-off was site dependent: head-and-neck gained substantial plan quality, whereas prostate and lung SBRT gained little beyond baseline. Negative levels predictably shortened delivery time at a fixed CP budget, with quantifiable quality loss. Conclusions: DMAT co-optimizes plan quality and modulation complexity under machine-aware timing and explicit user control, making quality-time trade-offs transparent and navigable and supporting time-constrained workflows such as motion management and adaptive radiotherapy.
ER  -