Two-Laser Heterodyne Detection System for ALPS II

Abstract

The Any Light Particle Search II employs a highly sensitive heterodyne detection system to measure an ultra-weak electromagnetic field that is reconverted from axions inside a regeneration cavity (RC). The initial design of the heterodyne system utilized a local oscillator laser (LO) that was resonant with the RC to form an interference beatnote with the weak signal field exiting the cavity. A weakness of this design is that it is possible for the out-of-mode field component of the LO to be larger than the in-mode component, allowing its noise to dominate the optical component of the noise budget and reducing the SNR of the experiment. This problem can be addressed by introducing a second, non-resonant laser as the LO. Since the in-mode light of this laser does not couple to the cavity, significantly more of its power is reflected than when the LO is resonant. We present a model for the measurement noise that predicts these design changes increase the SNR by a factor of roughly 35. This model was then confirmed experimentally by injecting a weak signal to the RC and examining the difference in the sensitivity of the detection system in each of these configurations.

Related

  1. Searching for long-lived ALPs with a laser-assisted optical dump
    Tong Li, Haolong Wang, Man Yuan
    arXivPreprintCC BY 4.0Full textHigh-energy & particle physicsarXiv
  2. Broadband heterodyne interferometry with a chirped femtosecond laser in the H-band
    Félix Gudin, Nicolas Forget
    arXivPreprintarXiv licenceFull textInstrumentation & methodsOptics & photonicsarXiv
  3. Coherent detection in 3D FMCW flash LIDAR with large FOV: part II – heterodyne efficiency in the image plane: erratum
    Anis Daami, Laurent Frey, Florence Rigal +1
    Optics ExpressPeer-reviewedPublisher termsApplied physics & instrumentationCrossref
  4. Phase-Sensitive Heterodyne Detection of MW using EIT Harmonics in Rydberg Atoms
    Mangesh Bhattarai, Rishav Hui, Sumanta Khan +3
  5. Homodyne versus heterodyne detection for classifying families of optical quantum states from finite records of detection events
    Franciszek Grzywa, Sebastian Dolata, Karol Bartkiewicz
    arXivPreprintarXiv licenceFull textQuantum physics & quantum informationarXiv
BibTeX
@misc{fradrich2026twolaser,
  title = {{Two-Laser Heterodyne Detection System for ALPS II}},
  author = {Henry Frädrich and Aaron D. Spector and Axel Lindner and Guido Müller},
  howpublished = {arXiv},
  year = {2026},
  month = oct,
  doi = {10.48550/arxiv.2610.03376},
  eprint = {2610.03376},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2610.03376},
  note = {CC BY 4.0},
}
RIS
TY  - UNPB
TI  - Two-Laser Heterodyne Detection System for ALPS II
AU  - Henry Frädrich
AU  - Aaron D. Spector
AU  - Axel Lindner
AU  - Guido Müller
PY  - 2026
DA  - 2026/10/21
PB  - arXiv
DO  - 10.48550/arxiv.2610.03376
UR  - https://arxiv.org/abs/2610.03376
AB  - The Any Light Particle Search II employs a highly sensitive heterodyne detection system to measure an ultra-weak electromagnetic field that is reconverted from axions inside a regeneration cavity (RC). The initial design of the heterodyne system utilized a local oscillator laser (LO) that was resonant with the RC to form an interference beatnote with the weak signal field exiting the cavity. A weakness of this design is that it is possible for the out-of-mode field component of the LO to be larger than the in-mode component, allowing its noise to dominate the optical component of the noise budget and reducing the SNR of the experiment. This problem can be addressed by introducing a second, non-resonant laser as the LO. Since the in-mode light of this laser does not couple to the cavity, significantly more of its power is reflected than when the LO is resonant. We present a model for the measurement noise that predicts these design changes increase the SNR by a factor of roughly 35. This model was then confirmed experimentally by injecting a weak signal to the RC and examining the difference in the sensitivity of the detection system in each of these configurations.
ER  -