Skip to content
DraconiticResearch
Search Sources API
197,768 studies31 sourcesUpdated just now
PreprintCC BYmedRxiv

Data Reduction in SARS-CoV-2 Amplicon Sequencing: Effects of Read Subsampling and Normalization on Consensus Quality, Lineage Assignment, and Computational Burden

  1. 1State of Utah, Department of Health and Human Services, Unified Public Health Laboratory, Salt Lake City, Utah

Abstract

BackgroundAmplicon-based next-generation sequencing is a cornerstone of viral genomic surveillance, but it often produces datasets with highly uneven read coverage due to PCR amplification bias. This leads to excessive data generation and substantial computational overhead for downstream bioinformatic analysis.

ResultsWe evaluated the efficacy of two data reduction strategies on 220 SARS-CoV-2 clinical specimens and 12 wastewater samples: random subsampling with SeqKit and read depth normalization with BBNorm. FASTQ files were reduced to target depths from 10X to 10,000X to compare genome coverage, lineage assignment concordance, and computational resource usage. Both strategies markedly reduced total processing time. For clinical isolates, read depth normalization corrected for amplification bias resulting in highly concordant lineage assignments at a target depth of just 200X. Random subsampling preserved inherent bias but produced reliable assignments at depths over 500X. Reducing target depths below 500X in complex wastewater mixtures severely degraded variant deconvolution accuracy and heavily skewed lineage abundance profiles for both methods.

ConclusionBoth random subsampling and read depth normalization successfully reduce computational overhead while preserving key clinical sequencing metrics at appropriate reduction settings. The optimal method depends on the analytical goal, ranging from computationally lightweight random subsampling for rapid lineage assignment, to read depth normalization for generating high-quality consensus sequences. However, aggressive data reduction should be avoided in environmental surveillance, where maintaining a high baseline sequencing depth is critical for accurate mixed-variant deconvolution.

Related

  1. Towards Democratizing CNS Tumor Classification: 10-fold reduction in methylation sequencing cost with the Flongle Flow Cell
    A. Grunwald, G. Feinberg-Gorenshtein, H. Toledano +3
    medRxivPreprintCC BY-NCFull textOncologymedRxiv
  2. Direction of discordance between PET/CT, EBUS-TBNA, and multidisciplinary tumor board nodal assignment in non-small cell lung cancer : A retrospective observational study
    Orkun Eray Terzi, Ezgi Demirdöğen, Nilüfer Aylin Acet Öztürk +2
    MedicinePeer-reviewedCC BYFull textGeneral medicineEurope PMC
  3. CONORM: Context-Aware Entity Normalization for Adverse Drug Event Detection
    Anthony Yazdani, Hossein Rouhizadeh, Alban Bornet +1
    ACM Transactions on Computing for HealthcarePeer-reviewedLicence not statedFull text9 citedPharmacology & toxicologyOpenAlex
  4. Factors Associated with CD4+/CD8+ Ratio Normalization in People Living with HIV During Long-Term ART
    Gamze Konyalı, Fatma Merve Koçak, Ayse İnci
    Infectious diseases & clinical microbiologyPeer-reviewedCC BY-NCFull textGeneral medicineEurope PMC
  5. The impact of normalization of histology on disease course in microscopic colitis: a retrospective cohort study
    Jennifer Frances Namuli Kizza-Brown, Ashwin N Ananthakrishnan
    Inflammatory Bowel DiseasesPeer-reviewedPublisher termsFull textEpidemiology & public healthPMC
BibTeX
@misc{ortega2026data,
  title = {{Data Reduction in SARS-CoV-2 Amplicon Sequencing: Effects of Read Subsampling and Normalization on Consensus Quality, Lineage Assignment, and Computational Burden}},
  author = {Y. Ortega and P. Gupta and O. Olinares-Perdomo and K. F. Oakeson and E. L. Young},
  howpublished = {medRxiv},
  year = {2026},
  month = oct,
  doi = {10.64898/2026.10.05.26363801},
  url = {https://www.medrxiv.org/content/10.64898/2026.10.05.26363801v1},
  note = {CC BY},
}
RIS
TY  - UNPB
TI  - Data Reduction in SARS-CoV-2 Amplicon Sequencing: Effects of Read Subsampling and Normalization on Consensus Quality, Lineage Assignment, and Computational Burden
AU  - Y. Ortega
AU  - P. Gupta
AU  - O. Olinares-Perdomo
AU  - K. F. Oakeson
AU  - E. L. Young
PY  - 2026
DA  - 2026/10/05
PB  - medRxiv
DO  - 10.64898/2026.10.05.26363801
UR  - https://www.medrxiv.org/content/10.64898/2026.10.05.26363801v1
AB  - BackgroundAmplicon-based next-generation sequencing is a cornerstone of viral genomic surveillance, but it often produces datasets with highly uneven read coverage due to PCR amplification bias. This leads to excessive data generation and substantial computational overhead for downstream bioinformatic analysis.  ResultsWe evaluated the efficacy of two data reduction strategies on 220 SARS-CoV-2 clinical specimens and 12 wastewater samples: random subsampling with SeqKit and read depth normalization with BBNorm. FASTQ files were reduced to target depths from 10X to 10,000X to compare genome coverage, lineage assignment concordance, and computational resource usage. Both strategies markedly reduced total processing time. For clinical isolates, read depth normalization corrected for amplification bias resulting in highly concordant lineage assignments at a target depth of just 200X. Random subsampling preserved inherent bias but produced reliable assignments at depths over 500X. Reducing target depths below 500X in complex wastewater mixtures severely degraded variant deconvolution accuracy and heavily skewed lineage abundance profiles for both methods.  ConclusionBoth random subsampling and read depth normalization successfully reduce computational overhead while preserving key clinical sequencing metrics at appropriate reduction settings. The optimal method depends on the analytical goal, ranging from computationally lightweight random subsampling for rapid lineage assignment, to read depth normalization for generating high-quality consensus sequences. However, aggressive data reduction should be avoided in environmental surveillance, where maintaining a high baseline sequencing depth is critical for accurate mixed-variant deconvolution.
ER  -