Patient Satisfaction Among Complete and Partial Removable Denture Wearers: A Questionnaire Survey
6 affiliations
- 1Department of Prosthodontics, North Bengal Dental College and Hospital, Darjeeling, IND
- 2Department of Prosthodontics, Shaheed Kartar Singh Sarabha Dental College and Hospital, Sarabha, IND
- 3Department of Dentistry, Thundermist Health Center, Woonsocket, USA
- 4Department of Prosthodontics, K. M. Shah Dental College and Hospital, Sumandeep Vidyapeeth (Deemed to be University), Vadodara, IND
- 5Department of Prosthodontics, Baba Jaswant Singh Dental College, Hospital and Research Institute, Ludhiana, IND
- 6Department of Dentistry, Shree Rushabh Ajit Jain Medical and Charitable Trust, Thane, IND
Abstract
Introduction
Patient satisfaction is an important outcome for evaluating the success of removable prosthodontic rehabilitation. However, satisfaction may differ according to the type of prosthesis and change as patients adapt to their dentures. This study aimed to compare patient satisfaction among complete and removable partial denture (RPD) wearers at prosthesis delivery and after three months of use and to evaluate changes in satisfaction over this period.
Materials and methods
A prospective questionnaire-based study was conducted in the Department of Prosthodontics in a hospital in India in 2024. In total, 780 patients were included, comprising 455 complete removable denture and 325 RPD wearers. A 10-item patient-satisfaction questionnaire assessing the functional, comfort-related, esthetic, and psychosocial domains was administered at prosthesis delivery and after three months. Data were analyzed using the Mann-Whitney U test, Wilcoxon signed-rank test, and chi-square or Fisher's exact test, as appropriate.
Results
At prosthesis delivery, RPD wearers reported higher total satisfaction than complete removable denture wearers, with median scores of 37 and 34, respectively (p<0.001). After three months, satisfaction increased to 41 and 40, respectively, and the between-group difference was no longer significant (p=0.081). The improvement in satisfaction was significant in both groups (p<0.001) and was greater among complete removable denture wearers. The questionnaire demonstrated excellent internal consistency, with Cronbach's α of 0.91 at delivery and 0.94 after three months.
Conclusion
Patient satisfaction improved significantly during the first three months of removable denture use. Although RPD wearers showed greater initial satisfaction, the difference largely diminished following adaptation, highlighting the importance of follow-up and patient-centered prosthodontic care.
Related
- Determinants of patient satisfaction in the emergency department: A Structural Equation Modeling–Partial Least Squares (SEM-PLS) analysis
- Longevity of acrylic and cobalt-chromium removable partial dentures–A ten-year retrospective survival analysis of 1246 denture-wearing patients
- Parent Satisfaction with Pharmacist Services, Pharmacy Use, and Requirements for Improvement: A Questionnaire Survey
- Structural validity and internal consistency of the Client Satisfaction Questionnaire-8 among parents of children with ADHD: a cross-sectional study
- Salivary Parameters Before and After Removable Complete Denture Rehabilitation: A Systematic Review and Meta‐Analysis
BibTeX
@article{chowdhury2026patient,
title = {{Patient Satisfaction Among Complete and Partial Removable Denture Wearers: A Questionnaire Survey}},
author = {Adrita R Chowdhury and Priya Bagal and Hardik Dholakiya and Sameer Chauhan and T R Manjunatha and Manisha Nagar},
journal = {Cureus},
year = {2026},
month = oct,
doi = {10.7759/cureus.117836},
url = {https://doi.org/10.7759/cureus.117836},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Patient Satisfaction Among Complete and Partial Removable Denture Wearers: A Questionnaire Survey
AU - Adrita R Chowdhury
AU - Priya Bagal
AU - Hardik Dholakiya
AU - Sameer Chauhan
AU - T R Manjunatha
AU - Manisha Nagar
PY - 2026
DA - 2026/10/13
JO - Cureus
DO - 10.7759/cureus.117836
UR - https://doi.org/10.7759/cureus.117836
AB - Introduction Patient satisfaction is an important outcome for evaluating the success of removable prosthodontic rehabilitation. However, satisfaction may differ according to the type of prosthesis and change as patients adapt to their dentures. This study aimed to compare patient satisfaction among complete and removable partial denture (RPD) wearers at prosthesis delivery and after three months of use and to evaluate changes in satisfaction over this period. Materials and methods A prospective questionnaire-based study was conducted in the Department of Prosthodontics in a hospital in India in 2024. In total, 780 patients were included, comprising 455 complete removable denture and 325 RPD wearers. A 10-item patient-satisfaction questionnaire assessing the functional, comfort-related, esthetic, and psychosocial domains was administered at prosthesis delivery and after three months. Data were analyzed using the Mann-Whitney U test, Wilcoxon signed-rank test, and chi-square or Fisher's exact test, as appropriate. Results At prosthesis delivery, RPD wearers reported higher total satisfaction than complete removable denture wearers, with median scores of 37 and 34, respectively (p<0.001). After three months, satisfaction increased to 41 and 40, respectively, and the between-group difference was no longer significant (p=0.081). The improvement in satisfaction was significant in both groups (p<0.001) and was greater among complete removable denture wearers. The questionnaire demonstrated excellent internal consistency, with Cronbach's α of 0.91 at delivery and 0.94 after three months. Conclusion Patient satisfaction improved significantly during the first three months of removable denture use. Although RPD wearers showed greater initial satisfaction, the difference largely diminished following adaptation, highlighting the importance of follow-up and patient-centered prosthodontic care.
SN - 2168-8184
ER -