Comparative Validation of Vanadium(III) Chloride Reduction and Standard Methods for Nitrate Quantification in Organic-Rich Tropical Waters.
4 affiliations
- 1Grupo de Estudio del Recurso Hídrico, Escuela de Tecnología Química-Facultad de Tecnologías, Universidad Tecnológica de Pereira, Pereira 660003, Colombia.
- 2Laboratorio de Análisis de Aguas y Alimentos, Escuela de Tecnología Química-Facultad de Tecnologías, Universidad Tecnológica de Pereira, Pereira 660003, Colombia.
- 3Grupo de Investigación Infección e Inmunidad, Programa de Medicina, Facultad Ciencias de la Salud, Universidad Tecnológica de Pereira, Pereira 660003, Colombia.
- 4Grupo de Investigación Salud, Cuidado y Sociedad, Facultad Ciencias de la Salud, Unidad Central del Valle del Cauca, Tuluá 763022, Colombia.
Abstract
Natural organic matter (NOM) can interfere with the determination of nitrate (NO₃⁻) in tropical waters. This study compared three standard methods (APHA 4500-NO₃⁻ B, E, and J) with an optimized vanadium(III) chloride (VCl₃) reduction method coupled with the Griess reaction. The VCl₃ reaction was optimized at 1.0 M HCl in the VCl₃ reagent, 60 °C, and 45 min. At dissolved organic carbon (DOC) above 3.0 mg C/L, direct ultraviolet (UV) spectrophotometry (Method B) overestimated nitrate, and its 275 nm correction exceeded the 10% rejection criterion of the method. Spike recovery with enzymatic reduction (Method J) decreased to 54.1 ± 4.2% at 20.0 mg C/L DOC, whereas cadmium (Method E) and VCl₃ reduction gave 98.5 ± 2.2% and 101.2 ± 1.8%, respectively. For the VCl₃ method, the limit of quantification (LOQ) was 0.010 mg N-NO₃⁻/L (relative standard deviation, RSD, 3.8%; recovery 98.2% at this level), repeatability was 1.0-2.2% RSD, and inter-analyst intermediate precision was 2.2-3.8% RSD (cadmium reduction: 4.5-6.2%). In 12 natural water samples, the VCl₃ and cadmium results differed by less than 2%. The VCl₃ method avoids packed columns and cadmium waste.
Related
- Comparative Evaluation of Electrocoagulation for the Removal of Polyethylene and Polyvinyl Chloride Microplastics from Wastewater
- Vehicle-Based Methane Detection, Source Attribution, and Quantification in the Upstream Oil and Gas Sector: Method Overview and Controlled Release Validation
- Comparative evaluation of graphite-based cathode materials for autotrophic nitrate reduction and dissimilatory nitrate reduction to ammonium in bioelectrochemical systems.
- Surfactant-Enhanced In Situ Remediation Beneath an Occupied Residential Building: Reduction of the BTEX Vapor-Intrusion Source Term and Field Validation in a Single Field Season.
- Comparative Hydrodynamic Simulation and Field-Based Validation of an Extreme Urban Flood Event in Southern Bali
BibTeX
@article{vallejovargas2026comparative,
title = {{Comparative Validation of Vanadium(III) Chloride Reduction and Standard Methods for Nitrate Quantification in Organic-Rich Tropical Waters.}},
author = {Olga-Inés Vallejo-Vargas and Edwin Alzate-Rodriguez and Mariana Espinoza and Natalia Londoño and Leonardo Beltrán-Angarita},
journal = {Methods and protocols},
year = {2026},
month = nov,
doi = {10.3390/mps9060166},
url = {https://europepmc.org/article/MED/43081610},
note = {CC BY},
}
RIS
TY - JOUR
TI - Comparative Validation of Vanadium(III) Chloride Reduction and Standard Methods for Nitrate Quantification in Organic-Rich Tropical Waters.
AU - Olga-Inés Vallejo-Vargas
AU - Edwin Alzate-Rodriguez
AU - Mariana Espinoza
AU - Natalia Londoño
AU - Leonardo Beltrán-Angarita
PY - 2026
DA - 2026/11/11
JO - Methods and protocols
DO - 10.3390/mps9060166
UR - https://europepmc.org/article/MED/43081610
AB - Natural organic matter (NOM) can interfere with the determination of nitrate (NO₃⁻) in tropical waters. This study compared three standard methods (APHA 4500-NO₃⁻ B, E, and J) with an optimized vanadium(III) chloride (VCl₃) reduction method coupled with the Griess reaction. The VCl₃ reaction was optimized at 1.0 M HCl in the VCl₃ reagent, 60 °C, and 45 min. At dissolved organic carbon (DOC) above 3.0 mg C/L, direct ultraviolet (UV) spectrophotometry (Method B) overestimated nitrate, and its 275 nm correction exceeded the 10% rejection criterion of the method. Spike recovery with enzymatic reduction (Method J) decreased to 54.1 ± 4.2% at 20.0 mg C/L DOC, whereas cadmium (Method E) and VCl₃ reduction gave 98.5 ± 2.2% and 101.2 ± 1.8%, respectively. For the VCl₃ method, the limit of quantification (LOQ) was 0.010 mg N-NO₃⁻/L (relative standard deviation, RSD, 3.8%; recovery 98.2% at this level), repeatability was 1.0-2.2% RSD, and inter-analyst intermediate precision was 2.2-3.8% RSD (cadmium reduction: 4.5-6.2%). In 12 natural water samples, the VCl₃ and cadmium results differed by less than 2%. The VCl₃ method avoids packed columns and cadmium waste.
SN - 2409-9279
ER -