Interleukin-6, soluble interleukin-6 receptor, and outcomes after transcatheter aortic valve implantation: an exploratory biomarker substudy of a prospective multicenter cohort.
7 affiliations
- 1First Department of Cardiology, Medical University of Warsaw, Banacha 1A, Warsaw, 02-097, Poland. [email protected].
- 2Doctoral School, Medical University of Warsaw, Warsaw, Poland. [email protected].
- 3Department of Histology and Embryology, Faculty of Medicine, Medical University of Warsaw, Warsaw, Poland.
- 4Department of Cell Biology and Immunology, Centre of Postgraduate Medical Education, Warsaw, Poland.
- 5Department of Interventional Cardiology and Cardiac Surgery, University of Zielona Góra, Collegium Medicum, Zielona Gora, Poland.
- 6Department of Cardiac Surgery and Transplantology, Poznan University of Medical Sciences, Poznan, Poland.
- 7First Department of Cardiology, Medical University of Warsaw, Banacha 1A, Warsaw, 02-097, Poland.
Abstract
Background: Severe aortic stenosis can be treated with transcatheter aortic valve implantation (TAVI). Identifying clinical and laboratory factors that predict clinical outcomes after TAVI may facilitate more informed decision-making. We aimed to assess the incidence of major adverse cardiac and cerebrovascular events (MACCE) within 12 months after TAVI and long-term survival according to baseline interleukin-6 (IL-6) and soluble interleukin-6 receptor (sIL-6R) levels.
Methods and Results: In this biomarker substudy of a prospective multicenter cohort, we evaluated clinical outcomes after TAVI according to baseline IL-6 signal and sIL-6R concentration. We included only patients with an available baseline stored plasma sample. Patients were stratified into high and low IL-6 and sIL-6R groups. Two primary end points were analyzed: (i) 12-month MACCE, and (ii) long-term overall survival. Secondary end points included the individual components of MACCE. Stored baseline plasma was available for measurements in 62 patients who underwent TAVI between December 2018 and September 2021 across three clinical sites. Patients with high IL-6 had a higher 12-month MACCE risk in age- and sex-adjusted Firth penalized Cox regression analysis (HR 3.31; 95%CI 1.02–11.04, P = 0.0458) but not in unadjusted analysis (log-rank P = 0.07). The association was not robust to alternative cutoffs and the age- and sex-adjusted continuous analysis of IL-6 also did not show a statistically significant association (hazard ratio per 1-SD increase, 1.52, 95% CI, 0.86 to 2.46, P = 0.13). No significant associations were observed in the primary models between IL-6 and long-term overall survival or between sIL-6R and either primary end point.
Conclusions: High IL-6 signal at baseline may be associated with increased 12-month MACCE risk after TAVI, although this finding was sensitive to IL-6 categorization and was not statistically significant in continuous analysis. Baseline sIL-6R concentration was not significantly associated with the analyzed clinical outcomes. These findings should be considered exploratory and hypothesis-generating.
Graphical Abstract: In an exploratory biomarker substudy of 62 patients with severe aortic stenosis undergoing TAVI, high versus low IL-6 was associated with a higher hazard of MACCE at 12 months: age- and sex-adjusted hazard ratio 3.31, 95 percent confidence interval 1.02 to 11.04, p equals 0.0458. For long-term mortality, the hazard ratio was 2.38, confidence interval 0.86 to 6.34, p equals 0.09. For high versus low sIL-6R, the hazard ratio was 1.22 for MACCE, confidence interval 0.34 to 3.94, p equals 0.74, and 0.75 for long-term mortality, confidence interval 0.25 to 2.02, p equals 0.58. Each high-versus-low comparison included 20 versus 42 patients.
Supplementary Information: The online version contains supplementary material available at https://doi.org/10.1007/s11033-026-13152-4.
Related
- Tinnitus outcomes after cochlear implantation in single-sided deafness: an exploratory prospective multicenter study
- Peri-procedural immune blood cell count changes and pacemaker implantation after transcatheter aortic valve implantation: an exploratory study
- Long-term survival after transcatheter aortic valve implantation in nonagenarian patients: a multicenter real-world study
- Multicenter experience of hybrid transcatheter pulmonary valve implantation in patients with a large right ventricular outflow tract
- Twelve-month outcomes after fixation-free, 3-dimensional, lightweight SWING-Mesh implantation for minimally-invasive inguinal hernia repair: a multicenter prospective observational study
BibTeX
@article{procyk2026interleukin6,
title = {{Interleukin-6, soluble interleukin-6 receptor, and outcomes after transcatheter aortic valve implantation: an exploratory biomarker substudy of a prospective multicenter cohort.}},
author = {Grzegorz Procyk and Paweł Tyrna and Izabela Młynarczuk-Biały and Jan Budzianowski and Anna Olasińska-Wiśniewska and Janusz Kochman and Aleksandra Gąsecka},
journal = {Molecular biology reports},
year = {2026},
month = nov,
doi = {10.1007/s11033-026-13152-4},
url = {https://europepmc.org/article/MED/43007530},
note = {CC BY-NC-ND},
}
RIS
TY - JOUR
TI - Interleukin-6, soluble interleukin-6 receptor, and outcomes after transcatheter aortic valve implantation: an exploratory biomarker substudy of a prospective multicenter cohort.
AU - Grzegorz Procyk
AU - Paweł Tyrna
AU - Izabela Młynarczuk-Biały
AU - Jan Budzianowski
AU - Anna Olasińska-Wiśniewska
AU - Janusz Kochman
AU - Aleksandra Gąsecka
PY - 2026
DA - 2026/11/10
JO - Molecular biology reports
DO - 10.1007/s11033-026-13152-4
UR - https://europepmc.org/article/MED/43007530
AB - Background: Severe aortic stenosis can be treated with transcatheter aortic valve implantation (TAVI). Identifying clinical and laboratory factors that predict clinical outcomes after TAVI may facilitate more informed decision-making. We aimed to assess the incidence of major adverse cardiac and cerebrovascular events (MACCE) within 12 months after TAVI and long-term survival according to baseline interleukin-6 (IL-6) and soluble interleukin-6 receptor (sIL-6R) levels. Methods and Results: In this biomarker substudy of a prospective multicenter cohort, we evaluated clinical outcomes after TAVI according to baseline IL-6 signal and sIL-6R concentration. We included only patients with an available baseline stored plasma sample. Patients were stratified into high and low IL-6 and sIL-6R groups. Two primary end points were analyzed: (i) 12-month MACCE, and (ii) long-term overall survival. Secondary end points included the individual components of MACCE. Stored baseline plasma was available for measurements in 62 patients who underwent TAVI between December 2018 and September 2021 across three clinical sites. Patients with high IL-6 had a higher 12-month MACCE risk in age- and sex-adjusted Firth penalized Cox regression analysis (HR 3.31; 95%CI 1.02–11.04, P = 0.0458) but not in unadjusted analysis (log-rank P = 0.07). The association was not robust to alternative cutoffs and the age- and sex-adjusted continuous analysis of IL-6 also did not show a statistically significant association (hazard ratio per 1-SD increase, 1.52, 95% CI, 0.86 to 2.46, P = 0.13). No significant associations were observed in the primary models between IL-6 and long-term overall survival or between sIL-6R and either primary end point. Conclusions: High IL-6 signal at baseline may be associated with increased 12-month MACCE risk after TAVI, although this finding was sensitive to IL-6 categorization and was not statistically significant in continuous analysis. Baseline sIL-6R concentration was not significantly associated with the analyzed clinical outcomes. These findings should be considered exploratory and hypothesis-generating. Graphical Abstract: In an exploratory biomarker substudy of 62 patients with severe aortic stenosis undergoing TAVI, high versus low IL-6 was associated with a higher hazard of MACCE at 12 months: age- and sex-adjusted hazard ratio 3.31, 95 percent confidence interval 1.02 to 11.04, p equals 0.0458. For long-term mortality, the hazard ratio was 2.38, confidence interval 0.86 to 6.34, p equals 0.09. For high versus low sIL-6R, the hazard ratio was 1.22 for MACCE, confidence interval 0.34 to 3.94, p equals 0.74, and 0.75 for long-term mortality, confidence interval 0.25 to 2.02, p equals 0.58. Each high-versus-low comparison included 20 versus 42 patients. Supplementary Information: The online version contains supplementary material available at https://doi.org/10.1007/s11033-026-13152-4.
SN - 0301-4851
SN - 1573-4978
ER -