Daylight-Referenced Efficiency (DRE): A Radiometric Measure of Electric Light Source Efficiency

Abstract

Photopic luminous efficacy (lm/W) weights optical power strictly against human eye sensitivity V (lambda), creating a systemic metrological penalty for electric light sources engineered with broad spectral output in the ultraviolet (280-380 nm) or infrared (780-4000 nm) bands. Similarly, metrics evaluating chromaticity, color quality, or melanopic pathways assess photoreceptor responses strictly within the visual band, offering no measure of broad-spectrum physical radiant power conversion. To resolve this limitation, we introduce Daylight-Referenced Efficiency (eta_DRE), a radiometric framework that evaluates how efficiently an electric light source converts electrical power into an optical spectrum matching natural terrestrial daylight across domain Omega = [280 nm, 4000 nm]. The framework factorizes performance into primary physical quantities: domain-restricted Wall-Plug Efficiency (eta_wall [W_optical/W_elec]), measuring unweighted electrical-to-optical conversion, and Daylight Spectral Fidelity (eta_spec [unitless, 0-1]), quantifying geometric shape match to the ASTM G173 AM1.5G solar reference via total variation distance (1 - TVD). Multiplying total optical power by spectral fidelity yields the absolute Daylight-Referenced Output Power (P_dr [W]), establishing a direct physical flux quantity for lighting specification. Dividing by electrical drive power gives the summary metric Daylight-Referenced Efficiency (eta_DRE = eta_wall * eta_spec [W/W_elec]), measuring net reference-conforming radiant output per electrical Watt consumed. The mathematical architecture is reference-agnostic, domain-extensible, and maintains provable lower-bound monotonicity for eta_wall and eta_DRE under spectral truncation. Open-source reference software is provided to facilitate deployment and standardized rating of broad-spectrum light sources.

Related

  1. Two Strategies to Measure Spin-Orbit-Torque Efficiency Acting on the Insulating Magnet Li0.5Al0.7Fe1.8O4
    Orion Smedley, Thow Min Jerald Cham, Daisy O'Mahoney +10
    arXivPreprintCC BY 4.0Full textCondensed matterarXiv
  2. Traceable state-matched radiometric calibration for gated line-scan spectroscopy at 100 kHz
    Xuan-Sheng Huang, Shu-Bin Liu, Tian-Shuai Yuan +2
    Optics ExpressPeer-reviewedPublisher termsOptics & photonicsCrossref
  3. InP-compatible InGaAs/GaAsSb type-II superlattice eSWIR FPA with 2.7 µm cutoff: radiometric calibration and 3D noise analysis
    Jiaying Li, Hongyue Hao, Ruoyu Xie +9
    Optics ExpressPeer-reviewedPublisher termsOptics & photonicsCrossref
  4. Two Seconds per Day: Limitations of Circadian Burden Metrics in the Permanent Daylight Saving Time Debate
    José María Martín-Olalla, Jorge Mira
    arXivPreprintCC BY 4.0Full textStatistical & nonlinear physicsarXiv
  5. Facility for the radiometric characterization of space-based visible-near infrared detectors
    Miriam E. Cisneros-González, David Bolsée, Nuno Pereira +6
    Journal of Astronomical Telescopes Instruments and SystemsPeer-reviewedCC BYFull textApplied physics & instrumentationHAL
BibTeX
@misc{veto2026daylightreferenced,
  title = {{Daylight-Referenced Efficiency (DRE): A Radiometric Measure of Electric Light Source Efficiency}},
  author = {Peter Veto},
  howpublished = {arXiv},
  year = {2026},
  month = oct,
  doi = {10.48550/arxiv.2610.35746},
  eprint = {2610.35746},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2610.35746},
}
RIS
TY  - UNPB
TI  - Daylight-Referenced Efficiency (DRE): A Radiometric Measure of Electric Light Source Efficiency
AU  - Peter Veto
PY  - 2026
DA  - 2026/10/26
PB  - arXiv
DO  - 10.48550/arxiv.2610.35746
UR  - https://arxiv.org/abs/2610.35746
AB  - Photopic luminous efficacy (lm/W) weights optical power strictly against human eye sensitivity V (lambda), creating a systemic metrological penalty for electric light sources engineered with broad spectral output in the ultraviolet (280-380 nm) or infrared (780-4000 nm) bands. Similarly, metrics evaluating chromaticity, color quality, or melanopic pathways assess photoreceptor responses strictly within the visual band, offering no measure of broad-spectrum physical radiant power conversion. To resolve this limitation, we introduce Daylight-Referenced Efficiency (eta_DRE), a radiometric framework that evaluates how efficiently an electric light source converts electrical power into an optical spectrum matching natural terrestrial daylight across domain Omega = [280 nm, 4000 nm]. The framework factorizes performance into primary physical quantities: domain-restricted Wall-Plug Efficiency (eta_wall [W_optical/W_elec]), measuring unweighted electrical-to-optical conversion, and Daylight Spectral Fidelity (eta_spec [unitless, 0-1]), quantifying geometric shape match to the ASTM G173 AM1.5G solar reference via total variation distance (1 - TVD). Multiplying total optical power by spectral fidelity yields the absolute Daylight-Referenced Output Power (P_dr [W]), establishing a direct physical flux quantity for lighting specification. Dividing by electrical drive power gives the summary metric Daylight-Referenced Efficiency (eta_DRE = eta_wall * eta_spec [W/W_elec]), measuring net reference-conforming radiant output per electrical Watt consumed. The mathematical architecture is reference-agnostic, domain-extensible, and maintains provable lower-bound monotonicity for eta_wall and eta_DRE under spectral truncation. Open-source reference software is provided to facilitate deployment and standardized rating of broad-spectrum light sources.
ER  -