Skip to content
DraconiticResearch
Search Sources API
203,234 studies31 sourcesUpdated 45 min ago
Peer-reviewedCC BY 4.0Environmental Research Letters

Combustion-derived air pollution and heat from gas-fired appliances in commercial kitchens can exceed health-based guidelines

7 affiliations
  1. 1PSE Healthy Energy
  2. 2Stanford University
  3. 3New York University
  4. 4Forward Dining Solutions
  5. 5EcoChef
  6. 6School of Public Health, University of California
  7. 7Lawrence Berkeley National Lab

Abstract

Commercial kitchens may expose an estimated 15.7 million U.S. workers to elevated air pollution and heat, yet real-world measurements are limited and no prior study has compared commercial kitchens with gas-fired appliances to fully electric ones. We monitored pollutants and temperature in 27 commercial kitchens in California, Pennsylvania, and New York, including 24 natural gas- or propane-fired and 3 fully electric, during both work and idle periods. We measured nitrogen dioxide (NO ₂ ), carbon monoxide (CO), carbon dioxide (CO ₂ ), methane (CH ₄ ), benzene, and temperature at five locations within each kitchen relevant for chefs and cooks. During work hours, NO ₂ measured immediately outside ventilation hoods and in ambient kitchen areas exceeded the US EPA and world health organization 1 h guidelines (100 ppbv) in 17 of 24 (70%) kitchens with gas-fired appliances, reaching a maximum of >1000 ppbv in four kitchens. In total, we captured ∼170 work hours where the 1 h NO ₂ guideline was surpassed outside hoods or in ambient areas. CO levels also exceeded the California 1 h guideline (20 ppm) outside of hoods and in ambient kitchen areas for ten hours in three kitchens with gas-fired appliances, whereas benzene exceeded the California 1 h exposure guideline (8.4 ppb) for 12 h in five different kitchens. Likewise, 13 of 19 (68%) fossil-fueled kitchens exceeded OSHA’s proposed high-heat trigger of 90°F (32.2 °C), with 10 recording maximum temperatures above 100°F (37.8 °C). Overall, workers in ∼70% of kitchens with gas-fired appliances we sampled faced routine exposures to pollution and heat that exceeded health-based guidelines despite ventilation systems. None of the electric kitchens exceeded pollutant or temperature thresholds. While we frequently observed high pollutant concentrations during work hours, two-thirds of fossil-fueled kitchens exhibited higher median concentrations of NO ₂ , CO, CO ₂ , CH ₄ , and benzene overnight when ventilation was off but pilot lights remained lit. This finding has implications for cleaning and prep crews and for co-occupants in mixed-use buildings.

Related

  1. The Condyle–Fossa Relationship After Maxillary Expansion with Tooth-Borne and Tooth-Bone-Borne Appliances: A Retrospective Cone-Beam Computed Tomography Study at the End of Retention
    Esra Ağaoğlu Mogul, Merve Yelken Kendirci, Melda Pelin Akkitap
    Journal of Clinical MedicinePeer-reviewedCC BY 4.0General medicineCrossref
  2. External Apical Root Resorption with Clear Aligners Versus Fixed Appliances: A Scoping Review of Comparative Evidence, Treatment-Related Factors, Imaging Modalities and Consistency of Reported Data
    Bianca Luminița (Erhan) Groza, Emilia (Prodea) Rusu, Mariana Păcurar +8
    Journal of Clinical MedicinePeer-reviewedCC BY 4.0General medicineCrossref
  3. Women’s experience following orthodontic treatment with conventional fixed appliances and clear aligners: A qualitative study
    Nicolle San Nicolas Dubrull Lia Lucarelli, Gabriela Gonçalves Innocente, Pedro Augusto Thiene Leme +5
    PLOS OnePeer-reviewedCC BYFull textGeneral biologyEpidemiology & public healthPLOSEurope PMCPMC
  4. Toward sustainable mining: an in silico photothermal investigation of coal susceptibility to spontaneous combustion
    Pathikrit Gupta, Subhasri Chatterjee, Abhijeet Gorey +4
    Scientific ReportsPeer-reviewedCC BYFull textGeneral medicineDOAJ
  5. Multimodal graph-based deep learning for predicting heat of combustion as a key hazard indicator under GHS/CLP standards
    Osita Sunday Nnyigide, Haewon Byeon, Uchenna Esther Okpete
    Scientific ReportsPeer-reviewedCC BYFull textGeneral medicineDOAJ
BibTeX
@article{kashtan2026combustionderived,
  title = {{Combustion-derived air pollution and heat from gas-fired appliances in commercial kitchens can exceed health-based guidelines}},
  author = {Yannai S Kashtan and Eric D Lebel and Nicole Lucha and Colin Finnegan and Gan Huang and Tamara L Sparks and Abenezer Shankute and Antonio F Saporito and Christopher A Galarza and Robert B Jackson and Seth B C Shonkoff and Drew R Michanowicz},
  journal = {Environmental Research Letters},
  year = {2026},
  month = oct,
  doi = {10.1088/1748-9326/ae9d96},
  url = {https://iopscience.iop.org/article/10.1088/1748-9326/ae9d96},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Combustion-derived air pollution and heat from gas-fired appliances in commercial kitchens can exceed health-based guidelines
AU  - Yannai S Kashtan
AU  - Eric D Lebel
AU  - Nicole Lucha
AU  - Colin Finnegan
AU  - Gan Huang
AU  - Tamara L Sparks
AU  - Abenezer Shankute
AU  - Antonio F Saporito
AU  - Christopher A Galarza
AU  - Robert B Jackson
AU  - Seth B C Shonkoff
AU  - Drew R Michanowicz
PY  - 2026
DA  - 2026/10/06
JO  - Environmental Research Letters
DO  - 10.1088/1748-9326/ae9d96
UR  - https://iopscience.iop.org/article/10.1088/1748-9326/ae9d96
AB  - Commercial kitchens may expose an estimated 15.7 million U.S. workers to elevated air pollution and heat, yet real-world measurements are limited and no prior study has compared commercial kitchens with gas-fired appliances to fully electric ones. We monitored pollutants and temperature in 27 commercial kitchens in California, Pennsylvania, and New York, including 24 natural gas- or propane-fired and 3 fully electric, during both work and idle periods. We measured nitrogen dioxide (NO ₂ ), carbon monoxide (CO), carbon dioxide (CO ₂ ), methane (CH ₄ ), benzene, and temperature at five locations within each kitchen relevant for chefs and cooks. During work hours, NO ₂ measured immediately outside ventilation hoods and in ambient kitchen areas exceeded the US EPA and world health organization 1 h guidelines (100 ppbv) in 17 of 24 (70%) kitchens with gas-fired appliances, reaching a maximum of >1000 ppbv in four kitchens. In total, we captured ∼170 work hours where the 1 h NO ₂ guideline was surpassed outside hoods or in ambient areas. CO levels also exceeded the California 1 h guideline (20 ppm) outside of hoods and in ambient kitchen areas for ten hours in three kitchens with gas-fired appliances, whereas benzene exceeded the California 1 h exposure guideline (8.4 ppb) for 12 h in five different kitchens. Likewise, 13 of 19 (68%) fossil-fueled kitchens exceeded OSHA’s proposed high-heat trigger of 90°F (32.2 °C), with 10 recording maximum temperatures above 100°F (37.8 °C). Overall, workers in ∼70% of kitchens with gas-fired appliances we sampled faced routine exposures to pollution and heat that exceeded health-based guidelines despite ventilation systems. None of the electric kitchens exceeded pollutant or temperature thresholds. While we frequently observed high pollutant concentrations during work hours, two-thirds of fossil-fueled kitchens exhibited higher median concentrations of NO ₂ , CO, CO ₂ , CH ₄ , and benzene overnight when ventilation was off but pilot lights remained lit. This finding has implications for cleaning and prep crews and for co-occupants in mixed-use buildings.
SN  - 1748-9326
ER  -