Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 19 min ago
Peer-reviewedCC BYAnimal models and experimental medicine

Experimental glaucoma models as mechanistic instruments: A question-driven validity framework.

  1. 1Henan Key Laboratory of Ophthalmology and Visual Science, Henan Eye Hospital, Henan Provincial People's Hospital, People's Hospital of Zhengzhou University, People's Hospital of Henan University, Zhengzhou, Henan, China.

Abstract

Animal models provide experimental systems for investigating aqueous humor outflow, intraocular pressure (IOP) regulation, optic nerve head biomechanics and neural injury in glaucoma. This critical narrative review examines foundational studies and literature published from January 2014 through June 2026. We organize models by their use in pressure exposure, outflow dysfunction, inherited disease, normal-tension vulnerability and neural repair, recognizing that these applications overlap. Construct, face, temporal, measurement and therapeutic-predictive validity guide selection for a defined question. Pressure lowering, retinal ganglion cell (RGC) survival, axonal preservation and visual recovery answer different biological questions and do not form a universal endpoint hierarchy. Human outflow preparations, stem-cell-derived RGCs, retinal organoids and explants test whether animal findings extend to human tissue. Recent metabolic, autophagy and vascular-barrier studies show how pressure history, cell type and treatment timing affect the interpretation of neural benefit. We describe pressure-matched comparisons, compartment-specific measurements and model-selection examples to help distinguish observed treatment effects from the mechanisms assigned to them.

Related

  1. ECC-MR: an error-correcting-code framework for robust Mendelian randomization and pleiotropy decoding on correlated instruments
    J. Jiang, D. Hu, Q. Zhang +11
    medRxivPreprintCC BY-NCFull textHuman geneticsmedRxiv
  2. The right measure for the right question: A framework for domain‐matched patient‐reported outcome measure selection in knee arthroplasty research
    Lorenz Pichler, Moses El Kayali, Rüdiger von Eisenhart-Rothe +8
    Knee Surgery, Sports Traumatology, ArthroscopyPeer-reviewedLicence not statedFull textSurgery & anaesthesiaHAL
  3. Axon Content of the Circumpapillary Nerve Fiber Layer in Experimental Glaucoma
    Anish Kharal, Mitchell Sullivan, Nimesh Bhikhu Patel
    Investigative Ophthalmology & Visual SciencePeer-reviewedCC BY-NC-ND 4.0Full textGeneral medicinePMC
  4. Piezo1 mechanobiology in high myopia and glaucoma: compartment-specific evidence, gaps, and a hypothesis-generating susceptibility framework.
    Cong Zhao, Gong Chen, Chun Wang +2
    Frontiers in bioengineering and biotechnologyPeer-reviewedCC BYFull textGeneral medicineEurope PMCPMC
  5. Interpreting antiviral effects: from experimental measurements to mechanistic viral dynamics.
    Ashot Nersisyan
    Frontiers in molecular biosciencesPeer-reviewedCC BYFull textEpidemiology & public healthEurope PMCPMC
BibTeX
@article{wang2026experimental,
  title = {{Experimental glaucoma models as mechanistic instruments: A question-driven validity framework.}},
  author = {Gang Wang and Zhijie Li},
  journal = {Animal models and experimental medicine},
  year = {2026},
  month = nov,
  doi = {10.1002/ame2.70333},
  url = {https://europepmc.org/article/MED/43081853},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Experimental glaucoma models as mechanistic instruments: A question-driven validity framework.
AU  - Gang Wang
AU  - Zhijie Li
PY  - 2026
DA  - 2026/11/25
JO  - Animal models and experimental medicine
DO  - 10.1002/ame2.70333
UR  - https://europepmc.org/article/MED/43081853
AB  - Animal models provide experimental systems for investigating aqueous humor outflow, intraocular pressure (IOP) regulation, optic nerve head biomechanics and neural injury in glaucoma. This critical narrative review examines foundational studies and literature published from January 2014 through June 2026. We organize models by their use in pressure exposure, outflow dysfunction, inherited disease, normal-tension vulnerability and neural repair, recognizing that these applications overlap. Construct, face, temporal, measurement and therapeutic-predictive validity guide selection for a defined question. Pressure lowering, retinal ganglion cell (RGC) survival, axonal preservation and visual recovery answer different biological questions and do not form a universal endpoint hierarchy. Human outflow preparations, stem-cell-derived RGCs, retinal organoids and explants test whether animal findings extend to human tissue. Recent metabolic, autophagy and vascular-barrier studies show how pressure history, cell type and treatment timing affect the interpretation of neural benefit. We describe pressure-matched comparisons, compartment-specific measurements and model-selection examples to help distinguish observed treatment effects from the mechanisms assigned to them.
SN  - 2096-5451
SN  - 2576-2095
ER  -