Comparative Performance of an In-House and A Commercial ELISA for the Immunodiagnosis of Strongyloidiasis in Endemic Populations from Peru and Brazil.
4 affiliations
- 1Laboratório de Investigação Médica - LIM/06 (Imunopatologia da Esquistossomose) do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, São Paulo, Brasil. [email protected].
- 2Departamento de Patologia Básica, Universidade Federal do Paraná, Curitiba, Brasil. [email protected].
- 3Laboratório de Investigação Médica - LIM/06 (Imunopatologia da Esquistossomose) do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, São Paulo, Brasil.
- 4Laboratorio de Parasitología, Instituto de Medicina Tropical "Alexander Von Humboldt", Universidad Peruana Cayetano Heredia, Lima, Perú.
Abstract
Background
Human strongyloidiasis, caused by Strongyloides stercoralis, remains underdiagnosed, particularly in endemic areas and among immunocompromised individuals. Serological tests have been widely used; however, they present limitations related to diagnostic variability, cross-reactivity, and cost, particularly in low- and middle-income countries.Objective
To evaluate and compare the diagnostic performance of a commercial ELISA and an in-house ELISA using a heterologous antigen derived from Strongyloides venezuelensis in different epidemiological settings, as well as immunocompromised patients.Methods
Serum samples from 183 individuals were analyzed, including immunocompetent Brazilian and Peruvian individuals and immunocompromised patients. Diagnostic performance was assessed based on sensitivity, specificity, accuracy, positive predictive value, and negative predictive value, with 95% confidence intervals (CI95%).Results
Among immunocompetent patients, both methods showed high sensitivity, reaching 95.0% (CI95%: 76-99%; commercial ELISA) and 100% (CI95%: 83-100%; in-house ELISA) in Brazil, and 95.7% (CI95%: 79-99%; commercial ELISA) and 100% (CI95%: 85-100%; in-house ELISA) in Peru. The in-house ELISA demonstrated higher specificity (86.0% (CI95%: 74-93%) in Brazil; 95.7% (CI95%: 85-99%) in Peru) compared with the commercial ELISA [82.5% (CI95%: 70-90%) in Brazil; 89.4% (CI95%: 77-96%) in Peru)], resulting in higher overall accuracy, particularly in Peru [97.1% (CI95%: 90-99%)]. The commercial ELISA showed a higher frequency of positive results, with a significant difference compared with the in-house assay. Among immunocompromised patients, lower reactivity was observed with the commercial ELISA compared with the in-house ELISA.Conclusion
The in-house ELISA demonstrated diagnostic performance similar to that of the commercial ELISA. These finding indicate that the use of heterologous antigens may represent a feasible and cost-effective alternative, with potential application in diagnostic strategies adapted to the epidemiological context and the host's immune status.
Related
- Development of a Machine-Learning Model for Strongyloidiasis Risk Stratification in Migrant Populations.
- Serodiagnosis of Human Strongyloidiasis in Brazil and Peru Using Strongyloides venezuelensis Antigens: A Comparative Study in Endemic Settings.
- QTL detection for fruit commercial quality traits in diploid and triploid banana populations
- Genetic and regulatory architecture of meat yield traits in commercial pig populations
- Assessing the comparative longitudinal immunogenicity of two commercial foot-and-mouth disease vaccines in crossbred dairy calves in Sebeta Hawas, Ethiopia
BibTeX
@article{corral2026comparative,
title = {{Comparative Performance of an In-House and A Commercial ELISA for the Immunodiagnosis of Strongyloidiasis in Endemic Populations from Peru and Brazil.}},
author = {Marcelo Andreetta Corral and William Henry Roldán and Dirce Mary Correia Lima Meisel and Marco Canales and Maria Angelica Terashima and Ronaldo Cesar Borges Gryschek and Fabiana Martins de Paula},
journal = {Acta parasitologica},
year = {2026},
month = nov,
doi = {10.1007/s11686-026-01445-4},
url = {https://europepmc.org/article/MED/43071212},
note = {CC BY},
}
RIS
TY - JOUR
TI - Comparative Performance of an In-House and A Commercial ELISA for the Immunodiagnosis of Strongyloidiasis in Endemic Populations from Peru and Brazil.
AU - Marcelo Andreetta Corral
AU - William Henry Roldán
AU - Dirce Mary Correia Lima Meisel
AU - Marco Canales
AU - Maria Angelica Terashima
AU - Ronaldo Cesar Borges Gryschek
AU - Fabiana Martins de Paula
PY - 2026
DA - 2026/11/23
JO - Acta parasitologica
DO - 10.1007/s11686-026-01445-4
UR - https://europepmc.org/article/MED/43071212
AB - Background Human strongyloidiasis, caused by Strongyloides stercoralis, remains underdiagnosed, particularly in endemic areas and among immunocompromised individuals. Serological tests have been widely used; however, they present limitations related to diagnostic variability, cross-reactivity, and cost, particularly in low- and middle-income countries.Objective To evaluate and compare the diagnostic performance of a commercial ELISA and an in-house ELISA using a heterologous antigen derived from Strongyloides venezuelensis in different epidemiological settings, as well as immunocompromised patients.Methods Serum samples from 183 individuals were analyzed, including immunocompetent Brazilian and Peruvian individuals and immunocompromised patients. Diagnostic performance was assessed based on sensitivity, specificity, accuracy, positive predictive value, and negative predictive value, with 95% confidence intervals (CI95%).Results Among immunocompetent patients, both methods showed high sensitivity, reaching 95.0% (CI95%: 76-99%; commercial ELISA) and 100% (CI95%: 83-100%; in-house ELISA) in Brazil, and 95.7% (CI95%: 79-99%; commercial ELISA) and 100% (CI95%: 85-100%; in-house ELISA) in Peru. The in-house ELISA demonstrated higher specificity (86.0% (CI95%: 74-93%) in Brazil; 95.7% (CI95%: 85-99%) in Peru) compared with the commercial ELISA [82.5% (CI95%: 70-90%) in Brazil; 89.4% (CI95%: 77-96%) in Peru)], resulting in higher overall accuracy, particularly in Peru [97.1% (CI95%: 90-99%)]. The commercial ELISA showed a higher frequency of positive results, with a significant difference compared with the in-house assay. Among immunocompromised patients, lower reactivity was observed with the commercial ELISA compared with the in-house ELISA.Conclusion The in-house ELISA demonstrated diagnostic performance similar to that of the commercial ELISA. These finding indicate that the use of heterologous antigens may represent a feasible and cost-effective alternative, with potential application in diagnostic strategies adapted to the epidemiological context and the host's immune status.
SN - 1230-2821
SN - 1896-1851
ER -