Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 22 min ago
Peer-reviewedCC BY-NC-ND 4.0BMC Pediatrics

Delayed umbilical venous catheter migration causing acute respiratory deterioration in a preterm neonate: a case report

  1. 1Department of Neonatology, IMS and SUM Hospital, Bhubaneswar, Odisha 751003 India

Abstract

Background: Umbilical venous catheters are often used in neonatal intensive care units and are usually considered relatively safe. Pleural effusion secondary to UVC extravasation is an uncommon but potentially life-threatening complication.

Case presentation: A 33-week, 1310 g preterm neonate initially improved following respiratory support with nasal CPAP after birth. On day 6 of life, he developed sudden respiratory deterioration requiring invasive ventilation. Chest radiograph and bedside lung ultrasound demonstrated a massive right pleural effusion. Pleural drainage yielded clear, straw coloured, transudative fluid with markedly elevated glucose concentration, suggesting extravasation of infused intravenous fluid. Although the UVC appeared appropriately positioned on the initial radiograph, subsequent imaging demonstrated catheter tip migration with distal kink below the diaphragm. Removal of the catheter resulted in rapid resolution of pleural effusion and complete clinical recovery, without recurrence.

Conclusion: Delayed migration of a previously well-placed UVC should be considered in the differential diagnosis of sudden unexplained respiratory deterioration in neonates. Pleural fluid with significantly elevated glucose, combined with bedside point-of-care ultrasonography, would help in the rapid diagnosis of catheter-related extravasation. Serial assessment of catheter position throughout the entire catheterization period, may play a crucial role and facilitate early detection of potential complications.

Related

  1. Delayed Umbilical Extrusion of a Ventriculoperitoneal Shunt Following Robotic-Assisted Laparoscopic Hysterectomy: A Case Report
    Alejandro M Castañer, Amanda Detres, Alejandro E Cedeño-Morán +3
    CureusPeer-reviewedCC BYFull textGeneral medicineEurope PMC
  2. Delayed deterioration after surgical treatment of a spinal dural arteriovenous fistula detected by three spinal angiographies: Case report
    Qiong Feng, Conghui Xu, Xiaodong Niu +1
    Radiology case reportsPeer-reviewedCC BY-NC-NDFull textGeneral medicineEurope PMC
  3. Skin safety during umbilical venous catheter insertion using 2% chlorhexidine gluconate in 70% isopropyl alcohol: a prospective observational study.
    Vito D'Andrea, Giorgia Prontera, Cecilia Monachini +4
    Italian journal of pediatricsPeer-reviewedCC BY-NC-NDFull textObstetrics, gynaecology & paediatricsEurope PMCPMC
  4. Downregulation of alcohol dehydrogenase family proteins suggests disrupted retinol metabolism in neonatal respiratory distress syndrome: an umbilical cord blood proteomics study
    Jing Wang, Ying Wei, Xuan Kan +1
    Frontiers in pediatricsPeer-reviewedCC BYFull textGeneral medicineEurope PMC
  5. Development and Internal Validation of a Prediction Model Incorporating Respiratory Muscle Function for CAT Score Deterioration in Stable COPD
    Muye Niu, Changye Wu, Shaoting Geng +2
    The clinical respiratory journalPeer-reviewedCC BYFull textGeneral medicineEurope PMC
BibTeX
@article{sahoo2026delayed,
  title = {{Delayed umbilical venous catheter migration causing acute respiratory deterioration in a preterm neonate: a case report}},
  author = {Devi Prasad Sahoo and Vijay Kumar Krishnegowda and Debasish Nanda},
  journal = {BMC Pediatrics},
  year = {2026},
  month = aug,
  doi = {10.1186/s12887-026-07583-y},
  url = {https://doi.org/10.1186/s12887-026-07583-y},
  note = {CC BY-NC-ND 4.0},
}
RIS
TY  - JOUR
TI  - Delayed umbilical venous catheter migration causing acute respiratory deterioration in a preterm neonate: a case report
AU  - Devi Prasad Sahoo
AU  - Vijay Kumar Krishnegowda
AU  - Debasish Nanda
PY  - 2026
DA  - 2026/08/28
JO  - BMC Pediatrics
DO  - 10.1186/s12887-026-07583-y
UR  - https://doi.org/10.1186/s12887-026-07583-y
AB  - Background: Umbilical venous catheters are often used in neonatal intensive care units and are usually considered relatively safe. Pleural effusion secondary to UVC extravasation is an uncommon but potentially life-threatening complication.  Case presentation: A 33-week, 1310 g preterm neonate initially improved following respiratory support with nasal CPAP after birth. On day 6 of life, he developed sudden respiratory deterioration requiring invasive ventilation. Chest radiograph and bedside lung ultrasound demonstrated a massive right pleural effusion. Pleural drainage yielded clear, straw coloured, transudative fluid with markedly elevated glucose concentration, suggesting extravasation of infused intravenous fluid. Although the UVC appeared appropriately positioned on the initial radiograph, subsequent imaging demonstrated catheter tip migration with distal kink below the diaphragm. Removal of the catheter resulted in rapid resolution of pleural effusion and complete clinical recovery, without recurrence.  Conclusion: Delayed migration of a previously well-placed UVC should be considered in the differential diagnosis of sudden unexplained respiratory deterioration in neonates. Pleural fluid with significantly elevated glucose, combined with bedside point-of-care ultrasonography, would help in the rapid diagnosis of catheter-related extravasation. Serial assessment of catheter position throughout the entire catheterization period, may play a crucial role and facilitate early detection of potential complications.
SN  - 1471-2431
ER  -